PTG 230 - GENERAL PURPOSE PRESSURE TRANSDUCER
he PTG 230 and PTA 232 are designed as a general purpose
industrial pressure transducer. Pressure ranges span from 0.5 to
T
60,000 PSIG. These transducers have stainless steel construction and utilize a complete four arm 350 ohm strain gage bridge. The
PTG 230 uses standard gage design. The PTA 232 has an internally
sealed 0 psia reference.
SPECIFICATIONS
PRESSURE RANGES:
LINEARITY:
HYSTERESIS:
REPEATABILITY:
MATERIAL:
TEMPERATURE RANGE:
OUTPUT:
BRIDGE RESISTANCE:
EXCITATION:
SAFE OVERLOAD:
PRESSURE PORTS:
CABLE:
AVAILABLE RANGES D” L”
0.5, 1, 2, 5 2.25 2.42
10, 15 1.50 2.35
25, 50, 75, 100, 150, 200 1.50 2.35
300, 500, 750, 1000, 1500, 2000, 3000, 5000, 75001.50 2.35
10,000, 15,000, 20,000, 30,000 1.50 2.39
50,000, 60,000 1.50 2.21
*Stocked ranges are in bold type. **Consult Cooper.
0.5 psig to 60,000 psig
±0.15% F.S.
±0.10% F.S.
±0.05% F.S.
Stainless Steel
60˚ to 160˚ F
0.5 psig - 1mv/psi
1 psig to 2 psig - 1-2 mv/v
5 psig to 60,000 psig - 3mv/v
350 ohm
10 Vdc
50% Over Capacity
0.5 psia to 1,500 psia - 1/4-18 NPT Male
2000 psia to 15,000 psia - 1/4-18 NPT Female
20,000 psia to 60,000 psia Autoclave AE F250-C
As Required - mating conn. not incl.
(PTO6A-10-6S)
• STAINLESS STEEL
• MANY OPTIONS
• 0.5 TO 60,000 PSI
• OPTIONAL AMPLIFIED OUTPUT
PRESSURE TRANSDUCER
COOPER INSTRUMENTS & SYSTEMS
PTA 232 - ABSOLUTE PRESSURE TRANSDUCER
SPECIFICATIONS
PRESSURE RANGES:
LINEARITY:
HYSTERESIS:
REPEATABILITY:
MATERIAL:
TEMPERATURE RANGE:
OUTPUT:
BRIDGE RESISTANCE:
EXCITATION:
SAFE OVERLOAD:
PRESSURE PORTS:
CABLE:
AVAILABLE RANGES D” L”
5 2.25 2.09
10, 15, 25, 50, 75, 100, 150, 200, 300, 500, 750 1.50 2.09
1000, 1500 1.50 2.35
2000, 3000, 5000, 7500, 10,000 1.50 2.39
15,000, 20,000, 30,000, 50,000, 60,000 1.50 2.21
*Stocked prices are in bold type. **Consult Cooper.
5 psia to 60,000 psia
±0.15% F.S.
±0.10% F.S.
±0.05% F.S.
Stainless Steel
60˚ to 160˚ F
5 psig to 60,000 psig - 3 mv/v
350 ohm
10 Vdc
50% Over Capacity
5 psia to 1,500 psia - 1/4-18 NPT Male
2000 psia to 15,000 psia - 1/4-18
NPT Female
20,000 psia to 60,000 psia - Autoclave
AE F250-C
As Required - mating conn. not incl.
(PTO6A-10-6S)
12/16/04