DCM 480 LVDT SIGNAL CONDITIONING MODULE
LVDT Signal Conditioning Module
he DCM 480 offers low cost and simple conditioning for
LVDT. The DCM 480 provides the necessary circuitry for
T
the transducer excitation, zero and scale adjustments. The
housing is constructed of a robust die-cast aluminium enclosure,
sealed to IP65 and fitted with IP65 rated cable glands which provide
total protection against the ingress of water or dust.
GENERAL
• CHANNELS:
• TEMPERATURE
• MATERIAL:
• POWER REQUIRED
1
32º to 185º F
Aluminum Housing-IP 65
12 to 36 Vdc Universal Polarity
TRANSDUCER
• EXCITATION:
• INPUTS ACCEPTED:
0.5V, 5mA rms 5kHz Sinusoidal
30 mv to 4V rms
AMPLIFIER
• ACCURACY:
• ANALOG OUTPUT:
• BANDWIDTH:
±0.05% F.S.
2-Wire, 4-20mA
250Hz, with Filter 25Hz (Flat)
PHYSICAL
• DIMENSIONS:
4.92" L x 3.15" W x 2.2" D
• SELECTABLE FILTERING
• FOR USE WITH LVDT
TRANSDUCERS
• ALUMINUM HOUSING SEALED
TO IP65
DCM 482
he DCM 482 low cost and simple conditioning for LVDT.
The DCM 482 provides the necessary circuitry for the
T
transducer excitation, zero and scale adjustments. The
housing is constructed of a robust die-cast aluminium inclosure,
sealed to IP65 and fitted with IP65 rated cable glands which
provide total protection against the ingress of water or dust.
LVDT SIGNAL CONDITIONING MODULE
GENERAL
• CHANNELS:
• TEMPERATURE:
• MATERIAL:
• POWER REQUIRED:
1
14º to 140º F
Aluminum Housing-IP 65
±6 to ±18 Vdc or 12 to 36 Vdc
TRANSDUCER
• EXCITATION:
• INPUTS ACCEPTED:
• CALIBRATION METHOD:
• BRIDGE RESISTANCE:
1V rms 5kHz, 25 mA
±250 mV Max
Potentiometer
120 ohm min.
AMPLIFIER
• ACCURACY:
• ANALOG OUTPUT:
• BANDWIDTH:
±0.04%
±4 or ±10 Vdc depending on load or
4-20 (3 wire) into 550 Ohms Max
Flat to 500Hz
COOPER INSTRUMENTS & SYSTEMS
• ±5 VDC OR ±10 VDC OUTPUT
• CONDITIONS LVDT AND INDUCTIVE
SENSORS
• EASY TO ACCESS ZERO AND GAIN
• BANDWIDTH FLAT TO 500Hz
PHYSICAL
• DIMENSIONS:
www.cooperinstruments.com sales@cooperinstruments.com
6" L x 2.5" W x 1.34" D
1-800-344-3921
Revised 11/22/02