Cooper & Hunter GEN12AA-D3DNA1C/I, GENAA-D3DNA1C/I, GEN18AA-D3DNA1C/I Installation Manual

MULTI
DUCTLESS INVERTER
HEAT PUMP
INSTALLATION
MANUAL
PANEL CONSOLE TYPE
INDOOR UNIT
Contents
The figures in this manual may be different with the material objects, please
refer to the material objects for reference.
This appliance is not intended for use by persons (including children) with reduced physical , sensory or mental capabilities or lack of experience and knowledge,unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Thank you for choosing a
C&H Multi Ductless Heat Pump!
You can feel confident in your selection because the same
pride incraftsmanship and engineering knowledge that goes
into millions of other C&H installed products worldwide has
gone into your unit. Please read this owners manual carefully before operationand retain it for future reference.
INSTALLATIONINSTRUCTIONS
1. Installation of indoor unit...........................................................................................1
2. Routine check after installation.................................................................................9
3. Configuration of connection pipe and additional volume of refrigerant......................10
INSTALLATION INSTRUCTIONS
The appliance shall not be installed in the laundry.
Installation of indoor unit
Such a place where cool air can be distributed
Such a place where condensation water is easily
Such a place that can handle the weight of indoor unit.
Such a place which has easy access for maintenance.
drained out.
throughout the room.
SELECTION OF INSTALLATION LOCATION.
Each type is similar to the other as follows;
THERE ARE 2 STYLES OF INSTALLATION.
CEILING TYPE FLOOR TYPE
Schematic drawing of hooks:
Where there is too much of oil area. Where it is acid base area.
Where there is irregular electrical supply.
TOOCCUR.
AIR CONDITIONER TROUBLEIS LIABLE
CAUTIONS FOR INSTALLATION WHERE
8in
(
200mm
)
Indoor unit
The indoor unit should be sited in a place where:
1) the restrictions on installation specified in the indoor unit installation drawings are met.
2) both air intake and exhaust have clear paths met.
3) the unit is not in the path of direct sunlight.
4) the unit is away from the source of heat or steam.
5) there is no source of machine oil vapour (this may shorten indoor unit life).
6) cool(warm) air is circulated throughout the room.
7) the unit is away from electronic ignition type fluorwscent lamps
(inverter or rapid stert type) as they may shorten the remote
controller range.
8) the unit is at least 39in(1m) away from any television or
radio set(unit may cause interference with the picture or
sound).
Indoor Unit Installation Drawings
The indoor unit may be mounted in any of the three styles shown here.
Exposed
Floor lnstallation Wall Installation
Molding
Mounting plate
Half conceated
Concealed
Grid(field supply)
Location for securing the installation panel.
27in(
700
mm)
5in(
120
mm)
9in(
220
mm)
7in
(
170
mm)
1in(
30
mm)
25in(
644
mm)
120
mm
220
mm
6in
(
160
mm)
1in(
30
mm)
22in(
570
mm)
23in(
600
mm)
8in(
200
mm)
59in(150cm)
or more
59in(150cm)
6in(15cm) or
below from
the floor
59in(150cm)
or more
59in(150cm)
or more
or more
1
INSTALLATION PAPER PLANK
3”
(75)
Refrigerant piping
1)Drill a hole ( 2 1/8”(55mm) in diameter ) in the spot indicated by the symbol in the illustration as below .
2)The location of the hole is different depending on which side of the pipe is taken out .
3)For piping ,see Connecting the refrigerant pipe ,under Indoor Unit Installation(1).
4)Allow space around the pipe for a easier indoor unit pipe connection.
Min.allowable length
The suggested shortest pipe length is 98in(2.5m),in order to avoid noise from the outdoor unit and vibration. (Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is used.)
See the installation manual for the outdoor unit for the maximum pipe length.
CAUTION
14in(350mm)
wall
Refrigerant pipe
1 3/4”
(45)
1 3/4”
(45)
1 3/4”
(45)
1 3/4”
(45)
1 3/4”
(45)
2 3/8”
(60)
3
(75)
3”
(75)
3”
(75)
3”
(75)
1 3/4”
(45)
Left back piping
gnipipmottobthgiRgnipipmottobtfeL
Wall
Unit : in(mm)
Right back piping
Left/right piping
2
INSTALLATION INSTRUCTIONS
Installation of indoor unit
Floor
Drain piping
1)Use commercial regid polyvinyl chloride pipe general VP 20 pipe, outer diameter 1”(26mm), inner diameter 3/4”(20mm) for the drain pipe.
2)The drain hose (outer diameter 3/4”(18mm) at connecting end, 9”(220mm) long)is supplied with the indoor unit. Prepare the drain pipe picture below position.
3)The drain pipe should be inclined downward so that water will flow smoothly without any accumulation.(Should not be trap.)
4)Insert the drain hose to this depth so it won’t be pulled out of the drain pipe.
5)Insulate the indoor drain pipe with 3/8”(10mm) or more of insulation material to prevent condensation.
6)Remove the air filters and pour some water into the drain pan to check the water flows smoothly.
4”(100mm)
Drain hose
4”(100mm)
6”(150mm)
Vinyl chloride drain pipe
2”(50mm) or more
Reducer
Must be no trap
Do not touch water
3
INSTALLATION INSTRUCTIONS
Installation of indoor unit
Boring a wall hole and installing wall embedded pipe
For walls containing metal frame or metal board ,be sure to use a wall embedded
pipe and wall cover in the feed-through hole to prevent water leakage.
Be sure to caulk the gaps around the pipes with caulking material to prevent
water leakage.
1)Bore a feed-through hole of 2 1/8”(55mm) in the wall so it has a down slope toward the outside.
2)Insert a wall pipe into the hole.
3)Insert a wall cover into wall pipe .
4)After completing refrigerant piping, wiring, and drain piping, caulk pipe hole gap with putty.
Inside Outside
Caulking
Wall embedded pipe (field supply)
Wall hole cover
Wall embedded pipe (field supply)
Φ
2 1/8”
(
55
mm)