This appliance is not intended for use by persons (including children) with reduced physical,
or mental capabilities or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they are away from the appliance.
This marking indicates that this product should not be disposed with other household wastes
throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it respons bly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or
contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory ormental capabilities or lack of experience and
knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
Do not connect air conditioner to multi-purpose socket.
Otherwise, it may cause fire hazard.
Do disconnect power supply when cleaning air
conditioner. Otherwise, it may cause electric shock.
.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Do not wash the air conditioner with water to avoid
electric shock.
Do not spray water on indoor unit. It may cause electric
shock or malfunction.
After removing the filter, do not touch fins to avoid injury.
Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
1
Precautions
Warning
Maintenance must be performed by qualified
professionals. Otherwise, it may cause personal injury
or damage.
Do not repair air conditioner by yourself. It may cause
electric shock or damage. Please contact dealer when
you need to repair air conditioner.
Do not extend fingers or objects into air inlet or air
outlet. It may cause personal injury or damage.
Do not block air outlet or air inlet. It may cause
malfunction.
Do not spill water on the remote controller, otherwise the
remote controller may be broken.
When below phenomenon occurs, please turn off air
conditioner and disconnect power immediately,and then
contact the dealer or qualified professionals for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Circuit break trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
If the air conditioner operates under abnormal conditions,
it may cause malfunction,electric shock or fire hazard.
When turning on or turning off the unit by emergency
operation switch, please press this switch with an insulating
object other than metal.
Do not step on top panel of outdoor unit, or put heavy
objects. It may cause damage or personal injury.
2
Precautions
Warning
Attachment
Installation must be performed by qualified professionals.
Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing
the unit.
According to the local safety regulations, use qualified
power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation
of at least 3mm in all poles should be connected in fixed
wiring.
Including an circuit break with suitable capacity, please
note
magnet buckle
the circuit-short and
the following table.Air switch should be included
and heating buckle function, it can protect
overload.
Air Conditioner should be properly grounded. Incorrect
grounding may cause electric shock.
Don't use unqualified power cord.
Make sure the power supply matches with the
requirement of air conditioner.Unstable power supply or
incorrect wiring or malfunction. Please install proper power
supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and
grounding wire of power socket.
Be sure to cut off the power supply before proceeding
any work related to electricity and safety.
3
Precautions
Warning
Do not put through the power before finishing installation.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
The appliance shall be installed in accordance with
national wiring regulations.
Installation must be performed in accordance with the
requirement of NEC and CEC by authorized personnel
only.
The air conditioner is the first class electric appliance. It
must be properly grounding with specialized grounding
device by a professional. Please make sure it is always
grounded effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding
wire, which can't be used for other purposes.
The grounding resistance should comply with national
electric safety regulations.
The appliance must be positioned so that the plug is
accessible.
All wires of indoor unit and outdoor unit should be
connected by a professional.
If the length of power connection wire is insufficient,please
contact the supplier for a new one. Avoid extending the
wire by yourself.
4
Precautions
Warning
For the air conditioner with plug ,the plug should be
reachable after finishing installation.
For the air conditioner without plug, an circuit break
must be installed in the line.
If you need to relocate the air conditioner to another
place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and
far away from animals or plants.If it is unavoidable,
please add the fence for safety purpose.
The indoor unit should be installed close to the wall.
Working temperature range
Indoor side DB/WB(℃)Outdoor side DB/WB(℃)
Maximum cooling32/2343/26
Maximum heating27/-24/18
● The operating temperature range (outdoor temperature) for cooling only unit is
18℃~43℃; for heat pump unit is -7℃~ 43℃.
5
Parts Name
Indoor Unit
cooling
indicator
heating
indicator
(Display content or position may be different from above
graphics, please refer to actual products)
temp.
indicator
power
indicator
receiver
window
drying
indicator
Outdoor Unit
air inlet
panel
aux.button
horizontal louver
air outlet
display
remote controller
air inlet
Connection wire
air outlet
Notice:
Actual product may be different from above graphics, please refer to actual
products.
6
Buttons on remote controller
ON/OFF button
1
MODE button
2
+/- button
3
FAN button
4
button
5
1
3
4
6
8
10
12
11
2
CLOCK button
6
TIMER ON/TIMER OFF
7
button
5
X-F
8
AN button
(Note: X-FAN is the same with
BLOW.)
7
9
TEMP button
9
TURBO button
10
LIGHT button
11
SLEEP button
12
Introduction for icons on display screen
operation mode
auto mode
cool mode
dry mode
fan mode
heat mode
clock
sleep mode
Temp. display type
:set temp.
:outdoor ambient temp.
:indoor ambient
temp.
set fan speed
send signal
X-fan mode
set temperature
turbo mode
set time
TIMER ON /TIMER
OFF
child lock
light
up&down swing
7
8
Introduction for buttons on remote controller
1 ON/OFF button
Caution: After putting through the power, the air conditioner will give out a
sound. Operation indictor " " is ON (red indicator). After that, you can operate
the air conditioner by using remote controller.
Pressing this button can turn on or turn off the air conditioner. After turning on the air
conditioner, operation indicator" " on indoor unit’s display is ON (green indicator. The
colour is different for different models), and indoor unit will give out a sound.
2
MODE button
Press this button to select your required operation mode.
AUTO COOL DRY FAN HEAT
● When selecting auto mode, air conditioner will operate automatically according to ex sserP .llew sa deyalpsid eb ton lliw dna detsujda eb t’nac erutarepmet teS .gnittes yrotcaf
"FAN" button can adjust fan speed. Press " " button can adjust fan blowing angle.
● After selecting cool mode, air conditioner will operate under cool mode. Cool indicator
" " on indoor unit is ON. Press "+" or "-" button to adjust set temperature. Press "FAN"
button to adjust fan speed. Press " " button to adjust fan blowing angle.
● When selecting dry mode, the air conditioner operates at low speed under dry mode. Dry
indicator " " on indoor unit is ON. Under dry mode, fan speed can’t be adjusted. Press
" " button to adjust fan blowing angle.
● When selecting fan mode, the air conditioner will only blow fan, no cooling and no
heating. all indicators are OFF. Press "FAN" button to adjust fan
speed. Press " "
● When selecting heating mode, the air conditioner operates under heat mode. Heat
indicator " " on indoor unit is ON. Press "+" or "-" button to adjust set temperature
Press "FAN" button to adjust fan speed. Press " " button to adjust fan blowing angle.
(Cooling only unit won’t receive heating mode signal. If setting heat mode with remote
controller, press ON/OFF button can’t start up the unit).
Note:
● For preventing cold air, after starting up heating mode, indoor unit will delay 1~5
minutes to blow air (actual delay time is depend on indoor ambient temperature).
● Set temperature range from remote controller: 16~30℃; Fan speed: auto, low speed,
medium speed, high speed.
button to adjust fan blowing angle.
Introduction for buttons on remote controller
3
+" or "-" button
"
● Pressing "+" or "-" button once increases or decreases set temperature 1℃Holding "+"
or "-" button, 2s later, set temperature on remote controller will change quickly. On
change accordingly. (Temperature can’t be adjusted under auto mode)
● When setting TIMER ON, TIMER OFF or CLOCK, press "+" or "-" button to adjust time.
(Refer to CLOCK, TIMER ON, TIMER OFF buttons) When setting TIMER ON, TIMER
OFF or CLOCK, press "+" or "-" button to adjust time. (Refer to CLOCK, TIMER ON,
TIMER OFF buttons)
FAN button
4
Pressing this button can set fan speed circularly as: auto (AUTO), low( ), medium( ),
high( ).
● Pressing this button can select up&down swing angle. Fan blow angle can be selected
circularly as below:
no display
(horizontal louvers
stops at current position)
● When selecting " ", air conditioner is blowing fan automatically. Horizontal louver
will automatically swing up & down at maximum angle.
"
"
● Hold " " button over 2s to set your required swing angle. When reaching your required
angle, release the button.
"
"
Note:
● " " may not be available. When air conditioner receives this signal, the air
conditioner will blow fan automatically.
9
Introduction for buttons on remote controller
6
CLOCK button
Press this button to set clock time. " " icon on remote controller will blink. Press "+" or
"-" button within 5s to set clock time. Each pressing of "+" or "-" button, clock time will
increase or decrease 1 minute. Hold "+" or "-" button, 2s later, time will change quickly.
the time. " " icon stops blinking.
Note:
● Clock time adopts 24-hour mode.
● The interval between two operations can’t exceeds 5s. Otherwise, remote controller will
quit setting status. Operation for TIMER ON/TIMER OFF is the same.
7
TIMER ON/TIMER OFF button
● TIMER ON button
"TIMER ON" button can set the time for timer on. After pressing this button, " " icon
disappears and the word "ON" on remote controller blinks. Press "+" or "-" button
to adjust TIMER ON setting. After each pressing "+" or "-" button, TIMER ON setting will
increase or decrease 1min. Hold "+" or "-" button, 2s later, the time will change quickly
"
stop blinking. " " icon resumes displaying.Cancel TIMER ON: Under the condition
that TIMER ON is started up, press “TIMER ON” button to cancel it.
● TIMER OFF button
"TIMER OFF" button can set the time for timer off. After pressing this button, " " icon
disappears and the word "OFF" on remote controller blinks. Press "+" or "-" button to
adjust TIMER OFF setting. After each pressing "+" or "-" button, TIMER OFF setting
will increase or decrease 1min. Hold "+" or "-" button, 2s later, the time will change
"OFF" will stop blinking. " " icon resumes displaying. Cancel TIMER OFF. Under the
condition that TIMER OFF is started up, press "TIMER OFF" button to cancel it.
Note:
● Under on and off status, you can set TIMER OFF or TIMER ON simultaneously.
● Before setting TIMER ON or TIMER OFF, please adjust the clock time.
● After starting up TIMER ON or TIMER OFF, set the constant circulating valid. After that,
air conditioner will be turned on or turned off according to setting time. ON/OFF button
has no effect on setting. If you don’t need this function, please use remote controller to
cancel it.
"
"
"
"
"
8
X-FAN button
Press this button under cool and dry mode to start up x-fan function, and " " icon on
" " icon will disappear.
10
dna ,noitcnuf naf-x lecnac ot niaga nottub siht sserP .deyalpsid eb lliw rellortnoc etomer
Introduction for buttons on remote controller
Note:
● When x-fan function is on, if the air conditioner is turned off, indoor fan will still
operate at low speed for a while to blow the residual water inside the air duct.
● During x-fan operation, press X-FAN button to turn off x-fan function. Indoor fan will
stop operation immediately.
9
TEMP button
By pressing this button, you can see indoor set temperature, indoor ambient temperature
or outdoor ambient temperature on indoor unit’s display. The setting on remote
controlleris is selected circularly as below:
● When selecting " " or no display with remote controller, temperature indicator on
indoor unit displays set temperature.
● When selecting " " with remote controller, temperature indicator on indoor unit
displays indoor ambient temperature.
● When selecting " " with remote controller, temperature indicator on indoor unit
displays outdoor ambient temperature.
Note:
● Outdoor temperature display is not available for some models. At that time, indoor unit
receives " " signal, while it displays indoor set temperature.
● It’s defaulted to display set temperature when turning on the unit. There is no display in
the remote controller.
● Only for the models whose indoor unit has dual-8 display.
● When selecting displaying of indoor or outdoor ambient temperature, indoor
temperature indicator displays corresponding temperature and automatically turn to
no display
10
TURBO button
Under COOL or HEAT mode, press this button to turn to quickCOOL or quickHEAT
mode. " " icon is displayed on remote controller. Press this button again to exit turbo
function and " " icon will disappear.
11
SLEEP button
Under COOL, HEAT or DRY mode, press this button to start up sleep function. " " icon
is displayed on remote controller. Press this button again to cancel sleep function and
" " icon will disappear.
12
LIGHT button
Pressing this button to turn off display light on indoor unit. " icon on remote controller
disappears. Press this button again to turn on display light. " " icon is displayed.
"
11
Function introduction for combination buttons
Child lock function:
Press "+"and "-" simultaneously to turn on or turn off child lock function. When child
lock function is on," " icon is displayed on remote controller. If you operate the remote
controller, it won’t send signal.
Temperature display switchover function:
Under OFF status, press "-" and “MODE” buttons simultaneously to switch temperature
display between ℃ and ℉.
Operation guide
1. After putting through the power, press "ON/OFF" button on remote controller to turn on
the air conditioner.
2. Press "MODE" button to select your required mode:AUTO, COOL, DRY, FAN, HEAT.
3. Press "+" or "-" button to set your required temperature. (Temperature can’t be
adjusted under auto mode).
4. Press "FAN" button to set your required fan speed: auto, low, medium and high speed.
5. Press " " button to select fan blowing angle.
Replacement of batteries in remote controller
1. Press the back side of remote controller marked with
""
of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and make
sure the position of "+" polar and "-" polar are correct.
3. Reinstall the cover of battery box.
signal sender
battery
reinstall
remove
Cover of battery box
Note:
● During operation, point the remote control signal sender at the receiving window on indoor
unit.
● The distance between signal sender and receiving window should be no more than 8m, and
there should be no obstacles between them.
telephone; remote controller should be close to indoor unit during operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the batteries.
● If the display on remote controller is fuzzy or there’s no display, please replace batteries.
12
Emergency operation
If remote controller is lost or damaged, please use auxiliary button to turn
on or turn off the air conditioner. The operation in details are as below:
As shown in the g. Open panel, press aux. button to turn on or turn off the
air conditioner. When the air conditioner is turned on, it will operate under
auto mode.
panel
aux. button
Clean and Maintenance
Note:
■ Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
■ Do not wash the air conditioner with water to avoid electric shock.
■ Do not use volatile liquid to clean the air conditioner.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth
or wet cloth to wipe it.
Note:
● Do not remove the panel when cleaning it.
13
Clean and Maintenance
Clean lter
Open panel
1
Pull out the panel to a certain
angle as shown in the g.
Remove lter
2
Remove the lter as indicated in the g.
Note:
Clean lter
● Use dust catcher or water to
3
clean the lter.
● When the lter is very dirty, use
the water (below 45℃) to clean
it, and then put it in a shady
and cool place to dry.
Install lter
4
Install the lter and then close the
panel cover tightly.
■ The lter should be cleaned every three months. If there is much dust in the
operation environment, clean frequency can be increased.
■ After removing the lter, do not touch ns to avoid injury.
■ Do not use re or hair dryer to dry the lter to avoid deformation or re hazard.
14
Clean and Maintenance
Checking before use-season
1. Check whether air inlets and air outlets are blocked.
2. Check whether air switch, plug and socket are in good condition.
3. Check whether lter is clean.
4. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
5. Check whether drainage pipe is damaged.
Checking after use-season
1. Disconnect power supply.
2. Clean lter and indoor unit’s panel.
3. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
Notice for recovery
1. Many packing materials are recyclable materials.
Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or
consultant service center for the correct disposal method.
15
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
can’t be eliminated, please contact local dealer or qualied professionals.
PhenomenonCheck itemsSolution
Indoor unit
can’t receive
remote
controller’s
signal or
remote
controller
has no
action.
No air
emitted
from
indoor
unit
● Whether it's interfered severely
(such as static electricity, stable
voltage)?
● Whether remote controller is
within the signal receiving
range?
● Whether there are obstacles?
● Whether remote controller is
pointing at the receiving
window?
● Is sensitivity of remote contro ller low; fuzzy display and no
display?
● No display when operating
remote controller?
● Fluorescent lamp in room?
● Air inlet or air outlet of indoor
unit is blocked?
● Under heating mode, indoor
temperature is reached to set
temperature?
● Heating mode is turned on just
now?
● Pull out the plug. Reinsert
the plug after about 3min, and
then turn on the unit again.
● Signal receiving range is 8m.
● Remove obstacles.
●
Select proper angle and point
the remote controller at the re ceiving window on indoor unit.
● Check the batteries. If the
power of batteries is too low,
please replace them.
● Check whether remote cont-
roller appears to be damaged.
If yes, replace it.
● Take the remote controller
close to indoor unit.
● Turn off the uoresent lamp
and then try it again.
● Eliminate obstacles.
● After reaching to set temper-
ature, indoor unit will stop bl owing out air.
● In order to prevent blowing
out cold air, indoor unit will be
started after delaying for sev eral minutes, which is a nor mal phenomenon.
16
Malfunction analysis
Phenomenon
Air conditioner can’t
operate
Mist is emitted from
indoor unit’s
air outlet
Set temperature can’t
be adjusted
Check itemsSolution
● Power failure?
● Is plug loose?
● Air switch trips off or fuse is
burnt out?
● Wiring has malfunction?
● Unit has restarted immediately
after stopping operation?
● Whether the function setting
for remote controller is
correct?
● Indoor temperature and hum-
idity is high?
● Unit is operating under auto
mode?
● Your required temperature
exceeds the set temperature
range?
● Wait until power recovery.
● Reinsert the plug.
● Ask professional to replace
air switch or fuse.
● Ask professional to replace it.
● Wait for 3min, and then turn
on the unit again.
● Reset the function.
● Because indoor air is cooled
rapidly. After a while, indoor
temperature and humidity will
be decrease and mist will
disappear.
● Temperature can’t be adju-
sted under auto mode.
Please switch the operation
mode if you need to adjust
temperature.
● Set temperature range:
16℃~30℃.
Cooling
(heating)
effect is
not good.
● Voltage is too low?
● Filter is dirty?● Clean the lter.
● Set temperature is in proper
range?
● Door and window are open?● Close door and window.
● Wait until the voltage
resumes normal.
● Adjust temperature to proper
range.
17
Malfunction analysis
PhenomenonCheck itemsSolution
Odours are
emitted
Air conditioner
operates normally suddenly
Outdoor
unit has
vapor
“Water
owing”
noise
Cracking
noise
● Whether there’s odour source,
such as furniture and cigarette,
etc.
● Whether there’s interference,
such as thunder, wireless
devices, etc.
● Heating mode is turned on?
● Air conditioner is turned on or
turned off just now?
● Air conditioner is turned on or
turned off just now?
● Eliminate the odour source.
● Clean the lter.
● Disconnect power, put back
power, and then turn on the
unit again.
● During defrosting under he-
ating mode, it may generate
vapor, which is a normal
phenomenon.
● The noise is the sound of
refrigerant owing inside
the unit, which is a normal
phenomenon.
● This is the sound of friction
caused by expansion and/or
contraction of panel or other
parts due to the change of
temperature.
18
Malfunction analysis
Error Code
● When air conditioner status is abnormal, temperature indicator on indoor unit will
ation of error code.
Indoor
display
Error code
Above indicator diagram is only
for reference. Please refer to
actual product for the actual
indicator and position.
Error code
H1Means defrosting status. It’s the normal phenomenon.
E5
U8
H6
C5
F1
F2
Note: If there're other error codes, please contact qualified professionals for
service.
It can be eliminated after restarting the unit. If not, please
It can be eliminated after restarting the unit. If not, please
It can be eliminated after restarting the unit. If not, please
Troubleshooting
Warning
■ When below phenomenon occurs, please turn off air conditioner and discon-
for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Air switch trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
■ If the air conditioner operates under abnormal conditions, it may cause
● Please contact the local agent for installation.
● Don't use unqualied power cord.
Selection of installation location
Basic requirement
Installing the unit in the following places maycause malfunction. If it is unavoidable, please consult the local
dealer:
1.The place with strong heat sources,
or volatile objects spread in the air.
2.The place with high-frequency
devices (such as welding machine,
medical equipment).
3.The place near coast area.
4.
The place with oil or fumes in the air.
5.The place with sulfureted gas.
6.Other places with special circums tances.
7.The appliance shall not be install ed in the laundry
Outdoor unit
Indoor unit
1. There should be no obstruction near air
inlet and air outlet.
2. Select a location where the condensat ion water can be dispersed easily and
won't affect other people.
3. Select a location which is convenient to
,
connect the outdoor unit and near the
power socket.
4. Select a location which is out of reach
for children.
5.
The location should be able to withstand
the weight of indoor unit and won't incr ease noise and vibration.
6.
The appliance must be installed 2.5m
7. Don't install the indoor unit right above
the electric appliance.
8. Please try your best to keep way from
fluorescent lamp.
will not affect neighborhood.
2. The location should be well ventilated and dry, in which the outdoor unit
won't be exposed directly to sunlight or strong wind.
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation
dimension diagram.
5. Select a location which is out of reach for children and far away from animals
or plants.If it is unavoidable, please add the fence for safety purpose.
21
Requirements for electric connection
Safety precaution
1. Must follow the electric safety regulations when installing the unit.
2. According to the local safety regulations, use qualied power supply circuit and
air switch.
3. Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
6. Do not put through the power before nishing installation.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualied persons in order to avoid a hazard.
8. The temperature of refrigerant circuit will be high, please keep the interconnec tion cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
Grounding requirement
1. The air conditioner is the rst class electric appliance. It must be properly
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
all poles should be connected in xed wiring.
6. Including an air switch with suitable capacity, please note the following table. Air
switch should be included magnet buckle and heating buckle function, it can
protect the circuit-short and overload. (Caution: please do not use the fuse only
for protect the circuit)
Air-conditioner
07K、09K、12K
Air switch capacity
10A
22
Installation of indoor unit
Step one: choosing installation location
Recommend the installation location to the client and then conrm it with the client.
Step two: install wall-mounting frame
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
level meter and then point out the screw xing holes on the wall.
2. Drill the screw xing holes on the wall with impact drill (the specication of drill
head should be the same as the plastic expansion particle) and then ll the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
then check if the frame is rmly installed by pulling the frame. If the plastic
expansion particle is loose, please drill another xing hole nearby.
Step three: open piping hole
1. Choose the position of piping hole according to the direction of outlet pipe. The
position of piping hole should be a little lower than the wall-mounted frame,
shown as below.
07、09K:12K:
Wall
Space
to the
wall
above
150mm
Left
Φ55mm
Rear piping hole
Mark in the middle of it
Level meter
Space
to the
wall
above
50mm
Right
Φ55mm
Rear piping hole
Wall
Wall
Space
to the
wall
above
50mm
Left
Φ55
Rear piping hole
Mark in the middle of it
Level meter
Space
to the
wall
above
150mm
Right
Φ55
Rear piping hole
Wall
2. Open a piping hole with the diameter of Φ55 on the selected outlet pipe
position. In order to drain smoothly, slant the piping hole on the wall slightly
downward to the outdoor side with the gradient of 5-10°.
23
leftright
Installation of indoor unit
Note:
● Pay attention to dust prevention and
take relevant safety measures when
opening the hole.
● The plastic expansion particles are
not provided and should be bought
locally.
Step four: outlet pipe
1. The pipe can be led out in the
direction of right, rear right, left or
rear left.
left
rear right
right
rear left
Indoor
5-10
2. When select leading out the pipe
from left or right, please cut off the
corresponding hole on the bottom
case.
outdoor
Φ55
cut off
the hole
Step ve: connect the pipe of indoor unit
1. Aim the pipe joint at the corresponding
bellmouth.
union nutpipe joint
2. Pretightening the union nut with hand.
3. Adjust the torque force by referring to the following sheet. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten
the union nut with torque wrench.
pipe
24
Installation of indoor unit
torque wrench
indoor pipe
open-end
wrench
union nut
pipe
Hex nut diameter Tightening torque (N.m)
Φ 9.52
4. Wrap the indoor pipe and joint of con-
nection pipe with insulating pipe, and
then wrap it with tape.
Step six: install drain hose
1. Connect the drain hose to the outlet pipe of
indoor unit.
drain hose
2. Bind the joint with tape.
Note:
● Add insulating pipe in the indoor
drain hose in order to prevent
condensation.
● The plastic expansion particles are
not provided.
outlet pipe
tape
Φ 6
Φ 12
Φ 16
Φ 19
15~20
30~40
40~55
60~65
70~75
insulating pipe
outlet
pipe
drain hose
insulating pipe
drain hose
Step seven: connect wire of indoor unit
1. Open the panel, remove the screw
on the wiring cover and then take
down the cover.
25
panel
screw
wiring cover
Installation of indoor unit
power connection
wire
cable-cross
hole
2. Make the power connection wire go
through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
3. Remove the wire clip; connect the power
connection wire to the wiring terminal
according to the color; tighten the screw
and then x the power connection wire
with wire clip.
07、09、12K Heat pump type:
violet
orangeblue
black
yellow-
green
outdoor unit connection
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Note:
● All wires of indoor unit and outdoor unit should be connected by a professional.
● If the length of power connection wire is insufcient, please contact the supplier
for a new one. Avoid extending the wire by yourself.
● For the air conditioner with plug, the plug should be reachable after nishing
installation.
● For the air conditioner without plug, an air switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.
26
Installation of indoor unit
drain hose
band
connection pipe
indoor power cord
upper hook
lower hook of
wall-mounting frame
Step eight: bind up pipe
1. Bind up the connection pipe, power
cord and drain hose with the band.
indoor and
indoor unit
outdoor power cord
gas
pipe
band
2. Reserve a certain length of drain
hose and power cord for installation
when binding them. When binding to
a certain degree, separate the indoor
power and then separate the drain
hose.
liquid pipe
drain hose
3. Bind them evenly.
4. The liquid pipe and gas pipe should
be bound separately at the end.
Note:
● The power cord and control wire
can't be crossed or winding.
● The drain hose should be bound
at the bottom.
Step nine: hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the wall
hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and closed to the wall.
indoor
wall pipe
outdoor
sealing gum
Note:
● Do not bend the drain hose too excessively in order to prevent blocking.
27
Installation of outdoor unit
Step one: x the support of outdoor unit
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.
Note:
● Take sufcient protective measures when
installing the outdoor unit.
●
Make sure the support can withstand at least
four times of the unit weight.
● The outdoor unit should be installed at least
3cm above the oor in order to install drain
joint.
● For the unit with cooling capacity of 2300W
~5000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6000W
~8000W, 8 expansion screws are needed;
for the unit with cooling capacity of 10000W
~16000W, 10 expansion screws are needed.
at least 3cm above the floor
Step two: install drain joint
(Only for cooling and heating
unit)
1. Connect the outdoor drain joint into
the hole on the chassis, as shown in
the picture below.
2. Connect the drain hose into the drain
vent.
drain vent
Drain hose
chassis
outdoor drain joint
Step three: x outdoor unit
1. Place the outdoor unit on the
support.
2. Fix the foot holes of outdoor unit
with bolts.
foot holes
foot holes
28
Installation of outdoor unit
Step four: connect indoor and outdoor pipes
1. Remove the screw on the right han dle of outdoor unit and then remove
the handle.
screw
handle
2. Remove the screw cap of valve and
aim the pipe joint at the bellmouth of
pipe.
liquid pipe
liquid
valve
gas pipe
gas valve
3. Pretightening the union nut with
hand.
pipe joint
union nut
4. Tighten the union nut with torque
wrench by referring to the sheet
below.
Hex nut diameter
Φ 6
Φ 9.52
Φ 12
Φ 16
Φ 19
Tightening torque
(N.m)
15~20
30~40
40~55
60~65
70~75
1. Remove the wire clip; connect the po-
wer connection wire and signal control
wire (only for cooling and heating unit) to the wiring terminal according to the
handle
07 09 12K Heat pump type:
2 4
N(1)
blue
black violet
ye lowgreen
Indoor unit connection
5
orange
29
Installation of outdoor unit
the drain hose
can't raise
upwards.
The water outlet
can't be placed
in water
2. Fix the power connection wire and signal control wire with wire clip (only for
cooling and heating unit).
Note:
● After tighten the screw, pull the power cord slightly to check if it is rm.
● Never cut the power connection wire to prolong or shorten the distance.
Step six: neaten the pipes
1. The pipes should be placed along the wall,
bent reasonably and hidden possibly. Min.
semidiameter of bending the pipe is 10cm.
2. If the outdoor unit is higher than the wall
hole, you must set a U-shaped curve in the
pipe before pipe goes into the room, in
order to prevent rain from getting into the
room.
Note:
● The through-wal height of drain hose
shouldn't be higher than the outlet
pipe hole of indoor unit.
● Slant the drain hose slightly dow nwards. The drain hose can't be
curved, raised and uctuant, etc.
U shaped curve
drain hose
wall
● The water outlet can't be placed
in water in order to drain smoothly.
30
The drain hose can't be fluctuant
The drain hose
can't be fluctuant
The water
outlet can't be
fluctuant
Vacuum pumping
Use vacuum pump
1. Remove the valve caps on
the liquid valve and gas
valve and the nut of refri gerant charging vent.
2. Connect the charging hose
of piezometer to the refri gerant charging vent of gas
valve and then connect the
other charging hose to the
vacuum pump.
3. Open the piezometer com pletely and operate for
10-15min to check if the
pressure of piezometer re mains in -0.1MPa.
4. Close the vacuum pump
and maintain this status for
1-2min to check if the pres sure of piezometer remains
in -0.1MPa. If the pressure decreases, there may be leakage.
5. Remove the piezometer, open the valve core of liquid valve and gas valve
completely with inner hexagon spanner.
6. Tighten the screw caps of valves and refrigerant charging vent.
liquid valve
gas valve
refrigerant charging
vent
nut of refrigerant
charging vent
piezometer
valve cap
vacuum pump
inner hexagon
spanner
close
open
Lo Hi
Leakage detection
1. With leakage detector:
Check if there is leakage with leakage detector.
2. With soap water:
If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more
than 3min. If there are air bubbles coming out of this position, there's a leakage.
31
Check after installation
● Check according to the following requirement after nishing installation.
Items to be checkedPossible malfunction
Has the unit been installed rmly?The unit may drop, shake or emit noise.
Have you done the refrigerant leakage
test?
Is heat insulation of pipeline sufcient?
Is water drained well?
It may cause insufcient cooling
(heating) capacity.
It may cause condensation and water
dripping.
It may cause condensation and water
dripping.
Is the voltage of power supply according to the voltage marked on the
nameplate?
Is electric wiring and pipeline installed
correctly?
Is the unit grounded securely?It may cause electric leakage.
Does the power cord follow the speci-
cation?
Is there any obstruction in the air inlet
and outlet?
The dust and sundries caused during
installation are removed?
The gas valve and liquid valve of
connection pipe are open completely?
It may cause malfunction or damaging
the parts.
It may cause malfunction or damaging
the parts.
It may cause malfunction or damaging
the parts.
It may cause insufcient cooling
(heating) capacity.
It may cause malfunction or damaging
the parts.
It may cause insufcient cooling
(heating) capacity.
Test operation
1. Preparation of test operation
● The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the power, press ON/OFF button on the remote controller to start
operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
● If the ambient temperature is lower than 16℃, the air conditioner can’t
start cooling.
32
Conguration of connection pipe
1. Standard length of connection pipe
● 5m, 7.5m, 8m.
2. Min. length of connection pipe is 3m.
3. Max. length of connection pipe and max. high difference.
Cooling
capacity
5000Btu/h
(1465W)
7000Btu/h
(2051W)
9000Btu/h
(2637W)
12000Btu/h
(3516W)
18000Btu/h
(5274W)
4. The additional refrigerant oil and refrigerant charging required after prolonging
connection pipe
● After the length of connection pipe is prolonged for 10m at the basis of
standard length, you should add 5ml of refrigerant oil for each additional 5m
of connection pipe.
● The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):
Additional refrigerant charging amount = prolonged length of liquid pipe ×
additional refrigerant charging amount per meter
● When the length of connection pipe is above 5m, add refrigerant according to
the prolonged length of liquid pipe. The additional refrigerant charging amount
per meter is different according to the diameter of liquid pipe. See the
following sheet.
Max length
of connection pipe
1525510
1530510
1530520
20301020
25301020
Max height
difference
Cooling
capacity
24000Btu/h
(7032W)
28000Btu/h
(8204W)
36000Btu/h
(10548W)
42000Btu/h
(12306W)
48000Btu/h
(14064W)
Max length
of connection pipe
Max height
difference
33
Conguration of connection pipe
Additional refrigerant charging amount for R22, R407C, R410A and R134a
Diameter of connection pipe
Liquid pipe(mm)Gas pipe(mm)
Φ6
Φ6 or Φ9.52
Φ12
Φ16
Φ19
Φ22.2
Φ9.52 or Φ12
Φ16 or Φ19
Φ19 or Φ22.2
Φ25.4 or Φ31.8
_
_
Outdoor unit throttle
Cooling only(g/m) Cooling and heating(g/m)
15
15
30
60
250250
350
20
50
120
120
350
34
Pipe expanding method
pipe
pipe
smooth surface
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:
A: Cut the pipe
● Conrm the pipe length according to
the distance of indoor unit and
outdoor unit.
● Cut the required pipe with pipe cutter.
pipe cutter
E: Expand the port
● Expand the port with expander.
hard
expander
mold
pipe
leaningunevenburr
B: Remove the burrs
● Remove the burrs with shaper and
prevent the burrs from getting into
the pipe.
shaper
downwards
C: Put on suitable insulating pipe
D: Put on the union nut
● Remove the union nut on the indoor
connection pipe and outdoor valve;
install the union nut on the pipe.
union pipe
Note:
● "A" is different according to the
diameter, please refer to the sheet
below:
Outer diameter
(mm)
Φ6 - 6.35(1/4")
Φ9.52(3/8")
Φ12-12.7(1/2")
Φ15.8-16(5/8")
A(mm)
MaxMin
1.30.7
1.61.0
1.81.0
2.42.2
F: Inspection
● Check the quality of expanding port.
If there is any blemish, expand the
port again according to the steps
above.
improper expanding
pipe
the length is equal
35
leaning
damaged
surface
crack uneven
thickness
Designed by Cooper&Hunter International Corporation, Oregon, USA
www.cooperandhunter.com
E-mail: info@cooperandhunter.com
66129915261
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.