Operator Controls and Displays
On both control panel and remote keypad the LEDs
display the following functions:
a Glows steadily when mains power is present.
E Shows the state of the entry/exit zone.
1 - 6 Shows the state of detector zones 1 to 6.
T Glows steadily if the tamper loop is broken.
D Glows when the system is unset, flashes when part
set.
The keypad on the control panel and 9427 provide
the following keys:
O Used to set the panel with individual zones tempo-
rarily omitted.
R Used to enter programming and setting/unsetting
commands.
P Pressing the two PA keys (1 and 3) at the same
time starts a PA alarm (if this function is enabled in
programming).
p Used to set the system with a preprogrammed
number of detectors omitted.
B Used to start a test of the sounders and strobe.
W Used to start a test of the detectors.
c Used to change the user access code.
C Used to enable or disable the Chime facility.
l Used to read the 10-event log. When reading the
log, pressing << (1) displays earlier events, and >>
(3) displays later events.
9448+ and 9448ES Hard Wired Control Panel User Guide.
© Scantronic Ltd. 2001
Every effort has been made to ensure that the contents of this book are correct, errors and omissions excepted.
However, neither the authors nor Scantronic accept any liability for loss or damage caused or alleged to be
caused directly or indirectly by this book. The contents of this book are subject to change without notice.
Printed in China.
2 496572
? ???
2
? ???
Enter via
designated
route
Go to
control panel
? ???
Exit Tone
Zone (x)Interrupted
? ???
Investigate cause and
restart setting sequence
TO FULL SET
Key-in your four digit user code (shown as ???? at
left). The exit tone starts. Leave premises via the
designated exit door. Exit tone stops after a preset
time and the D light goes dark. Your alarm system is
SET.
TO PART SET
Your alarm system may have been installed to allow
you to have part of the premises set while other
area(s) are off. To part set the system key in 2 then
ENTER, followed by your user code. Note that the
part set exit tone is usually a buzzer sound, but your
system may be programmed to silent set. While the
system is part set the D light flashes.
Note: If you enter your user code incorrectly four
times in a row then the system will raise a tamper
alarm. See opposite.
TO SWITCH OFF
Full Set: Enter by the designated entry door. Entry
tone starts. Go to control panel. Key-in your user
code. System is OFF.
Part Set: Go to control panel. Entry tone starts.
Key-in your user code. System is OFF.
Note: The system has a preset entry time to allow you
to get to the panel. When the entry time has elapsed
your system may be programmed to give an internal
alarm for 30 seconds. At the end of this 30 seconds the
system gives a full alarm (external sounder). Key in
your user code to cancel the alarm.
IF A ZONE LIGHT GLOWS WHILE SETTING
If, during setting, the sounder gives an
interrupted tone and a zone light glows, then a
detector is being triggered (maybe a door or window
is open).
Key in your user code to stop the tone.
Check the indicated zone(s) and if possible correct
the cause of the alarm. Try setting the system again.
If the fault persists, call your alarm installer.
If the Entry/Exit light glows, the exit door may be
open. Leave the premises and close the door. The
interrupted tone should change to a steady tone
when the door is closed and the system then sets as
normal.
UK
496572 3
UK
Repeat for each zone
Zone
No.
? ???
7
? ???
1
Enter
Building
3
Go To Control
Panel
? ???
Zone
Tamper
Panic
Reset any panic buttons
activated, then
? ???
TO OMIT A DETECTOR
You may need to temporarily set the system with
one or more detectors omitted. Key in the zone
number followed by OMIT for all the zones you want
to omit and then key in your user code. The system
flashes the light(s) of the omitted zone(s) during the
exit time and then sets. Note that you cannot omit a
panic or fire zone, or the EE zone.
The system will not raise an alarm if any omitted
detector is triggered during this setting cycle. The
system will reinstate the detector(s) and set normally the next time you set the system.
TO SWITCH CHIME ON OR OFF
Key in 7 then ENTER, followed by your user code to
switch Chime on or off. When Chime is on, the
internal sounder chimes when the chime zones
operate. Note that the Installer must program your
chime zones.
KEYPAD PA
Your system may be programmed to allow you to
start a Panic Alarm from the keypad (ask you
Installer). If so, then press keys 1 and 3 together to
start a Panic Alarm.
AFTER AN ALARM
To switch the bells off: Key-in your user code.
The sounders will stop and the zone light(s) for the
detectors that triggered the alarm will glow.
Reset system: You must reset the system before it
can be used again. Key-in your access code again.
All the zone lights should go off. The system is now
ready for use.
Fire Alarm: The fire alarm is a two tone siren note
from the internal sounder. Leave the building
immediately and call the Fire Brigade. Do not go
back into the building until it is safe to do so. Switch
the alarm off and reset the system as described
above. If you have trouble resetting the system
make sure that the fire detector is not being triggered.
Tamper or Panic Alarm: If you hear the internal
sounder when the system is off then look at the
control panel:
If the Tamper light glows then key-in your user code
to stop the sounder. Call your alarm installer for
service.
4 496572