USER GUIDE
HARDWIRED CONTROL PANEL
GUIDE UTILISATEUR
CENTRALE DALARME FILAIRE
UK
496572 1
UK
English
Operator Controls and Displays
On both control panel and remote keypad the LEDs display the following functions:
a Glows steadily when mains power is present. E Shows the state of the entry/exit zone.
1 - 6 Shows the state of detector zones 1 to 6.
T Glows steadily if the tamper loop is broken. D Glows when the system is unset, flashes when part
set.
The keypad on the control panel and 9427 provide the following keys:
O Used to set the panel with individual zones tempo-
rarily omitted.
R Used to enter programming and setting/unsetting
commands.
P Pressing the two PA keys (1 and 3) at the same
time starts a PA alarm (if this function is enabled in programming).
p Used to set the system with a preprogrammed
number of detectors omitted.
B Used to start a test of the sounders and strobe. W Used to start a test of the detectors. c Used to change the user access code. C Used to enable or disable the Chime facility. l Used to read the 10-event log. When reading the
log, pressing << (1) displays earlier events, and >> (3) displays later events.
9448+ and 9448ES Hard Wired Control Panel User Guide. © Scantronic Ltd. 2001 Every effort has been made to ensure that the contents of this book are correct, errors and omissions excepted. However, neither the authors nor Scantronic accept any liability for loss or damage caused or alleged to be caused directly or indirectly by this book. The contents of this book are subject to change without notice. Printed in China.
2 496572
? ???
2
? ???
Enter via
designated
route
Go to
control panel
? ???
Exit Tone
Zone (x)Interrupted
? ???
Investigate cause and
restart setting sequence
TO FULL SET
Key-in your four digit user code (shown as ???? at left). The exit tone starts. Leave premises via the designated exit door. Exit tone stops after a preset time and the D light goes dark. Your alarm system is
SET.
TO PART SET
Your alarm system may have been installed to allow you to have part of the premises set while other area(s) are off. To part set the system key in 2 then ENTER, followed by your user code. Note that the part set exit tone is usually a buzzer sound, but your system may be programmed to silent set. While the system is part set the D light flashes. Note: If you enter your user code incorrectly four times in a row then the system will raise a tamper alarm. See opposite.
TO SWITCH OFF
Full Set: Enter by the designated entry door. Entry
tone starts. Go to control panel. Key-in your user code. System is OFF. Part Set: Go to control panel. Entry tone starts. Key-in your user code. System is OFF.
Note: The system has a preset entry time to allow you to get to the panel. When the entry time has elapsed your system may be programmed to give an internal alarm for 30 seconds. At the end of this 30 seconds the system gives a full alarm (external sounder). Key in your user code to cancel the alarm.
IF A ZONE LIGHT GLOWS WHILE SET­TING
If, during setting, the sounder gives an interrupted tone and a zone light glows, then a detector is being triggered (maybe a door or window is open). Key in your user code to stop the tone. Check the indicated zone(s) and if possible correct the cause of the alarm. Try setting the system again. If the fault persists, call your alarm installer. If the Entry/Exit light glows, the exit door may be open. Leave the premises and close the door. The interrupted tone should change to a steady tone when the door is closed and the system then sets as normal.
UK
496572 3
UK
Repeat for each zone
Zone
No.
? ???
7
? ???
1
Enter
Building
3
Go To Control
Panel
? ???
Zone
Tamper
Panic
Reset any panic buttons
activated, then
? ???
TO OMIT A DETECTOR
You may need to temporarily set the system with one or more detectors omitted. Key in the zone number followed by OMIT for all the zones you want to omit and then key in your user code. The system flashes the light(s) of the omitted zone(s) during the exit time and then sets. Note that you cannot omit a panic or fire zone, or the EE zone. The system will not raise an alarm if any omitted detector is triggered during this setting cycle. The system will reinstate the detector(s) and set nor­mally the next time you set the system.
TO SWITCH CHIME ON OR OFF
Key in 7 then ENTER, followed by your user code to switch Chime on or off. When Chime is on, the internal sounder chimes when the chime zones operate. Note that the Installer must program your chime zones.
KEYPAD PA
Your system may be programmed to allow you to start a Panic Alarm from the keypad (ask you Installer). If so, then press keys 1 and 3 together to start a Panic Alarm.
AFTER AN ALARM
To switch the bells off: Key-in your user code.
The sounders will stop and the zone light(s) for the detectors that triggered the alarm will glow. Reset system: You must reset the system before it can be used again. Key-in your access code again. All the zone lights should go off. The system is now ready for use. Fire Alarm: The fire alarm is a two tone siren note from the internal sounder. Leave the building immediately and call the Fire Brigade. Do not go back into the building until it is safe to do so. Switch the alarm off and reset the system as described above. If you have trouble resetting the system make sure that the fire detector is not being trig­gered. Tamper or Panic Alarm: If you hear the internal sounder when the system is off then look at the control panel: If the Tamper light glows then key-in your user code to stop the sounder. Call your alarm installer for service.
4 496572