Cooper Controls 2 Chilli Control Panel, 5 Chilli Control Panel, 7Chilli Control Panel, 10 Chilli Control Panel, Chilli Installation Manual

Chilli Control Panel
86.01 mm (3.39 in)
86.01 mm (3.39 in)
39.01 mm (1.54 in)
Installation guide
Introduction
Welcome
The 2, 5, 7, and 10 button Chilli Control Panels from Cooper Controls provide an elegant solution. These buttons are used to output a memory or sequence which has been previously programmed into the Chilli / Spice dimmers on the network or to turn the outputs off.
Where tted, raise, and lower buttons compliment the
usual selection buttons to allow immediate changes to the intensity of any memory.
Dimensions
Supplied parts
Main body
Front cover
Screws
Fixing to a wallbox
The Chilli Control Panel ts into standard single gang
47mm deep UK backbox. Backboxes available from Cooper Controls.
Series 3 Panels (Clip-on Cover)
Use the screws provided to attach the panel to the backbox before clipping the front cover onto the assembly.
Control Wiring
Chilli Network
The Chilli Control Panel uses Chilli Network connections to ensure reliable and responsive transfer of control signals between multiple devices.
Cable connections are made to a removable 5-way connector block located at the rear of the Classic Control
Panel main body:
OV
(green
Pair)
KEY1
KEY2OVSHIELD
CAN TERM
CAN-L
(blue)
KEY3
SHIELD
(brown
pair)
CAN-H
(blue/ white)
+12V
(orange
pair)
Termination
The Chilli Network is a ‘daisy chain’ protocol that requires termination on the device located at either end of the chain.
DeviceDeviceDevice Devic
The Chilli Control Panel is supplied with termination enabled as standard. If the Chilli Control Panel is not connected as an end device in the chain, you need to disable termination.
To disable termination, move the jumper from the upper two pins to the lower pins, as shown here:
e
The following cable strategies may be used for wiring the Chilli Network.
It is not recommended to mix cable types in a single installation.
Use Belden cable to maximise network runs up to 1000m without a bridge/repeater.
Cable type: Belden 1502R or 1502P Maximum cable length: 1000m (3275 ft.) Devices per segment: 100 (without bridge or repeater)
Use CAT5 FTP for economy and wide availability, but there are tighter limitations on the network run without a bridge/repeater.
Cable type: CAT 5 FTP
Maximum cable length: 305m (1000 ft.)
Devices per segment: 100
Termination on
Termination off
Care and Maintenance
The front cover plate should only be cleaned gently with a clean, damp cloth. Abrasive cleaners, polishes, solvent based cleaning agents, or alkali based cleaners should not be used.
Operation
Startup
When a Chilli Control Panel is powered up the LEDs in all the buttons will ash once and then go off.
The panel then goes into its default state with all the button LEDs off, except for the 10 button panel in which the
“1-6” button only is lit.
Assigning an Area
All Chilli Control Panels are initially assigned to Area 1.
To assign a control panel to a specic area number (1 - 10) carry out the following operation:
1-6
1. Press and hold down the Memory 1 and OFF buttons for a few seconds until all the LEDs in the buttons ash.
1
OFF
2. Send a play memory/area message on the network, from another control panel, master controller or dimmer.
3. The control panel is assigned to the area number in the message.
4. Press the Memory 1 or OFF button to exit setup mode.
1
OFF
Outputting Memories
To playback (output) one of the memories previously programmed in the Chilli Pro or Spice dimmers on the Chilli network.
Two Button Panel
Five Button Panel
Seven Button Panel
OFF
OFF
chilli
chilli
Memory 1: Press the ‘1’ button.
net
Memories 1 - 4: Press the corresponding memory button.
net
Memories 1 - 4: Press the corresponding memory button.
1
OFF
chilli
net
Ten Button Panel
5
6
SEQU
1-6
OFF
7-12
net
chilli
Memories 1 - 6: Press the 1-6 button (if not already selected), then
1-6
press the corresponding memory button.
Memories 7 - 12: Press the 7-12 button (if not already selected), then
7-12
press the corresponding memory button.
The LED light in the memory button is lit and the outputs fade to the memo­ry levels in the memory’s fade time.
Raise and Lower Buttons
The 7 button Chilli Control Panel has Raise and Lower buttons which are used to adjust memory output levels.
The Raise and Lower buttons only affect the relevant dimmer channels on the network if memory 1, 2, 3, or 4 for the corresponding area is currently being output.
If memories 5 - 12 or a sequence are being output for the corresponding area, the Raise and Lower buttons will have no effect.
The Raise button increases the output levels of all channels in the memory for the corresponding area by 5%. Note - channels programmed at zero, remain at zero.
The Lower button decreases the output levels of all channels in the memory for the corresponding area by 5%.
Removing A Memory
To remove a memory from the outputs, press the OFF button on the control panel. The LED in the button is lit. The memory being output in the corresponding area will be faded out over three seconds.
OFF
Sequences
The 10 button Chilli Control Panel can be used to playback (output) any of the three sequences programmed in the Chilli dimmers on the network for the corresponding area. Sequences can be stopped from any Chilli Control Panel on the network that is assigned to the same area in which the sequence is running.
Starting a Sequence
Press the SEQUENCE button once, twice or three times to start sequence 1, 2 or 3 respectively. The light in the SEQUENCE button will turn on to indicate that a sequence is running and the light in button 1-3 will turn on to indicate which sequence (1-3) is running. When a sequence is running, each press of the SEQUENCE button will stop the cur­rent sequence and start the next sequence running automatically.
Stopping a Sequence
To stop a sequence that is running in an area, output a memory in that area, or press the OFF button on a control panel assigned to that area. The light in the SEQUENCE button will turn off.
SEQ
Network Locking
All control panels can be remotely locked and unlocked from a Master Controller via the network.
Manual Locking
The 10 button Chilli Control Panel can be locked and unlocked manually. To Lock: press and hold the “1-6” and “7-12” buttons together for approximately 5 seconds, until all 10 lights in the buttons will turn on to indicate that the lock state has changed.
Manual Unlocking
Press and hold the “1-6” and “7-12” buttons together for approximately 5 seconds, until lights in buttons 1, 3 and 5 are lit to indicate that the lock state has changed.
Key 1 Lock
When Key 1 is connected to 0 volts, all button presses on control panel are ignored.
Last Man Out Control Panel
Last Man Out panels are tted with a keyswitch. When the keyswitch is operated, the
control panel sends out an ‘OFF’ message for all areas after a delay of 30 seconds.
Key 2
When Key 2 is connected to 0 volts, all button presses on control panel are ignored and a last man out message is sent out.
KEY1
KEY2OVSHIELD
CAN TERM
KEY3
Key 3
When Key 3 connected to 0 volts, button presses on control panel are not ignored and a last man out message is sent out.
Chilli Network Alarm State
Chilli dimmers on the network have an Alarm Input. When this alarm input is activated, or changes from active to inactive, the dimmer sends out Alarm On and Alarm Off messages respectively. The dimmers ignore all messages from the control panels when the alarm state is active.
Infra Red Handset
The Infra Red (IR) handset has the following functions:
1. Buttons 1-4 turn on memories 1-4.
2. Off button turns memories off.
3. Raise button – increases the output Levels of the memory that is playing.
4. Lower button – increases the Levels of the memory that is playing.
Note 1: channels programmed at zero, remain at zero when the Raise button is pressed.
Note 2: The IR handset is not area specic. Consequently, when a memory is initiated from the handset, that memory is played
in all areas.
Zero 88 Usk House, Llantarnam Park,
Cwmbran, NP44 3HD. UK
Tel: +44 (0)1633 838088 Fax: +44 (0)1633 867880
www.zero88.com
All products manufactured by Cooper Controls and identied with the Zero 88 brand are warranted to be free from defects in material and workmanship and shall conform to and perform in accordance with Seller’s written specications.
For detailed warranty information, visit our website at www.zero88.com
This warranty will be limited to the repair or replacement, at Seller’s discretion, of any such goods found to be defective, upon their authorized return to Seller. This limited warranty does not apply if the goods have been damaged by accident,
abuse, misuse, modication or misapplication, by damage during shipment or by improper service.
There are no warranties, which extend beyond the hereinabove-limited warranty, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS.
No employee, agent, dealer, or other person is authorized to give any warranties on behalf of the Seller or to assume for the Seller any other liability in connection with any of its goods except in writing and signed by the Seller. The Seller makes no representation that the goods comply with any present or future federal, state or local regulation or ordinance. Compliance is the Buyer’s responsibility.
The use of the Seller’s goods should be in accordance with the provision of UL and/or other industry or military standards that are pertinent to the particular end use. Installation or use not in accordance with these codes and standards could be hazardous.
North America Headquarters
203 Cooper Circle
Peachtree City, GA 30269
P: 800-553-3879
F: 800-954-7016
www.coopercontrol.com
ControlsSales@cooperindustries.com
International Headquarters
20 Greenhill Crescent
Watford Business Park
Watford, Herts, WD18 8XG. UK
P: +44 (0)1923 495495
F: +44 (0)1923 228796
www.coopercontrol.com
enquiries@coopercontrols.co.uk
Document 73-843-00 IM8991 Iss.01
Loading...