Cooper B-Line B3100, B3100C, B3100F User Manual

Pipe Hangers
B3100 - Standard Clevis Hanger
SLIDE-RITE™ Clevis Hanger Features
Pipe will not ‘pinch’ when installing.
15° swing in either direction allows pipe to easily feed thru.
Engineered design aligns bolt holes for quicker overhead installation.
*SLIDE-RITE™ Clevis Hanger design, as shown below, for sizes 2, 2
Pat. No. 5,848,770
1
/2, 3, 4, 5 & 6.
5,924,655
Component of State of
California OSHPD Approved
Seismic Restraints System
A
E
D
(Rod Size)
Hanger Rod
Not Included
C
B
Center of pipe to top of hanger.
Center of pipe to bottom of
Minimum thread length of hanger rod
Top of cross bolt to bottom of hanger
rod nut inside the hanger.
B
C
D
Rod Take-Out
hanger rod.
E
F
Adjustment
Pipe Hangers
Nominal Pipe Size Rod Size A BCD
Part No. in. (mm) Std NFPA** in. (mm) in. (mm) in. (mm)
B3100-1/2
B3100-3/4
1
/2" (15)
3
/4" (20)
B3100-1 1" (25)
B3100-11/4 11/4" (32)
B3100-11/2 11/2" (40)
B3100-2 * 2" (50)
B3100-21/2 * 21/2" (65)
B3100-3 * 3" (80)
B3100-31/2 31/2" (90)
B3100-4 * 4" (100)
B3100-5 * 5" (125)
B3100-6 * 6" (150)
B3100-8 8" (200)
B3100-10 10" (250)
B3100-12 12" (300)
B3100-14 14" (350) 1"-8 -- 193/8"
B3100-16 16" (400) 1"-8 -- 213/8"
B3100-18 18" (450) 1"-8 -- 25"
B3100-20 20" (500) 11/4"-7 -- 283/4"
B3100-24 24" (600) 11/4"-7 -- 323/4"
B3100-30 30" (750) 11/4"-7 -- 3915/16"
B3100-36 36" (900) 11/4"-7 -- 46"
3
/8"-163/8"-16 21/8" (54.0) 13/4" (44.4)
3
/8"-163/8"-16 21/2" (63.5) 2" (50.8) 11/8" (28.6)
3
/8"-163/8"-16 27/8" (73.0) 21/4" (57.1) 13/8" (34.9)
3
/8"-163/8"-16 31/2" (88.9) 211/16" (68.2) 113/16" (46.0)
3
/8"-163/8"-16 4" (101.6)` 31/16" (77.8) 21/4" (57.1)
3
/8"-163/8"-16 41/2" (114.3) 35/16" (84.1) 21/2" (63.5)
1
/2"-133/8"-16 53/8" (136.5) 315/16" (100.0) 31/16" (77.8)
1
/2"-133/8"-16 61/2" (165.1) 43/4" (120.6) 315/16" (100.0)
1
/2"-133/8"-16 71/4" (184.1) 51/4" (133.3) 41/16" (103.2)
5
/8"-113/8"-16 73/4"
5
/8"-111/2"-13 83/4"
3
/4"-101/2"-13 105/16"
3
/4"-101/2"-13 123/4"
7
/8"-95/8"-11 151/8"
7
/8"-95/8"-11 171/2"
(196.8)
(222.2)
(261.9)
(323.8)
(384.2)
(444.5)
(492.1)
(542.9)
(635.0)
(730.2)
(831.8)
(1014.4)
(1168.4)
51/2" (139.7) 51/2" (139.7)
61/8" (155.6) 6" (152.4)
615/16" (176.2) 7" (177.8)
87/16" (214.3) 71/8" (181.0)
93/4" (247.6) 83/8" (212.7)
111/8" (282.6) 911/16" (246.1)
123/8" (314.3) 105/8" (269.9)
133/8" (339.7) 119/16" (293.7)
16" (406.4) 143/16" (360.3)
173/4" (450.8) 165/8" (422.3)
193/4" (501.6) 185/8" (473.1)
2415/16" (633.4) 223/4" (577.8)
28" (711.2) 25" (635.0)
15
/16" (23.8)
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
49
B-Line series Pipe Hangers & SupportsEaton
Pipe Hangers
B3100 - Standard Clevis Hanger
Size Range:1/2(15mm) to 36” (900mm)
Component of State of
California OSHPD Approved
Seismic Restraints System
Material: Steel
Function: Recommended for the suspension of non-insulated pipe or insulated pipe with a B3151 shield.
Note: When an oversized clevis is used, a pipe spacer should be placed over the cross bolt to assure that the
lower U-strap will not move in on the bolt. When attaching seismic bracing to the clevis hangers, a Fig. 1CBS (cross bolt spacer) must be installed. See Seismic Restraints Approval Guidelines.
Order pipe sleeves Fig. 1CBS-(pipe size) separately.
Approvals:
Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide
Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the B-Line/TOLCO Seismic Restraint Systems Guidelines. in the USA (UL) and Canada (cUL) for sizes (FM) for
3
/4(20mm) thru 12” (300mm) pipe.
3
/4(20mm) thru 12" (300mm). Factory Mutual Engineering Approved
Conforms to Federal Specification WW-H-171E & A-A-1192A, Type 1
and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 1.
Underwriter's Laboratories Listed
Also available to accommodate rod
schedule per National Fire Protection Association (NFPA) Pamphlet 13.
Maximum Temperature: 650°F
Standard Finish: Plain, Electro-Galvanized, DURA GREEN
(343°C).
, or Hot-Dip Galvanized
also available in Stainless Steel
Part
Order By:
number and finish.
For AWWA - Ductile Iron Clevis Hangers, see B3102, page 52.
Special Note: Do not use the dimensions shown in the B3100 chart for NFPA hanger sizes.
Contact
customer service
for NFPA rod sizing on 1/2(15mm) thru 12” (300mm) pipe.
Part numbers will be 1NFPA-pipe size.
E Adjustment F Design Load Approx. Wt./100
Part No. in. (mm) in. (mm) Lbs. (kN) Lbs. (kg)
B3100-1/2 21/2" (63.5)
B3100-3/4 21/2" (63.5)
B3100-1 21/2" (63.5)
B3100-11/4 21/2" (63.5)
7
/16" (11.1) 730 (3.25) 25 (11.3)
1
/2" (12.7) 730 (3.25) 29 (13.1)
5
/8" (15.9) 730 (3.25) 35 (15.9)
7
/8" (22.2) 730 (3.25) 40 (18.1)
B3100-11/2 21/2" (63.5) 13/16" (30.2) 730 (3.25) 42 (19.0)
B3100-2 * 21/2" (63.5) 15/8" (41.3) 730 (3.25) 52 (23.6)
B3100-21/2 * 21/2" (63.5) 2" (50.8) 1350 (6.00) 90 (40.8)
B3100-3 * 21/2" (63.5) 2" (50.8) 1350 (6.00) 110 (49.9)
B3100-31/2 21/2" (63.5) 2" (50.8) 1350 (6.00) 142 (64.4)
B3100-4 * 21/2" (63.5) 2" (50.8) 1430
B3100-5 * 21/2" (63.5) 2" (50.8) 1430
B3100-6 * 3" (76.2) 2" (50.8) 1940
B3100-8 31/2" (88.9) 25/16" (58.7) 2000
B3100-10 31/2" (88.9) 25/16" (58.7) 3600
B3100-12 31/2" (88.9) 25/8" (66.7) 3800
B3100-14 4" (101.6) 27/8" (73.0) 4200
B3100-16 4" (101.6) 211/16" (68.3) 4600
B3100-18 41/2" (114.3) 315/16" (100.0) 4800
B3100-20 5" (127.0) 53/8" (136.5) 4800
B3100-24 5" (127.0) 53/8" (136.5) 4800
B3100-30 5" (127.0) 61/4" (158.7) 6000
B3100-36 5" (127.0 57/16" (138.1) 6000
(6.36) 132 (59.9)
(6.36) 215 (97.5)
(8.63) 320 (145.1)
(8.89) 485 (220.0)
(16.01) 846 (383.7)
(16.90) 1083 (491.2)
(18.68) 1432 (649.5)
(20.46) 2200 (997.9)
(21.35) 2500 (1134.0)
(21.35) 4400 (1995.8)
(21.35) 5000 (2268.0)
(26.69) 6600 (2993.7)
(26.69) 8474 (3843.8)
Pipe Hangers
*SLIDE-RITE™ Clevis Hanger design, as shown above, for sizes 2, 21/2, 3, 4, 5 & 6.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
B-Line series Pipe Hangers & Supports
50
Eaton
Pipe Hangers
B3100C - Standard Clevis Hanger - Plastic Coated B3100F - Standard Clevis Hanger - Felt Lined for Copper Tubing
Size Range:1/2(15mm) to 8” (200mm) pipe
Material: Steel
3
Insulation Material:
/16(4.8mm) Felt
Service: The B3100F is designed for the suspension of copper tube so as to prevent electrolysis between tubing and hanger. The B3100C is designed for steel or other pipe types of the same O.D. Both B3100F and B3100C act to reduce noise and vibration in pipe or tubing systems.
Approvals: Underwriter's Laboratories Listed in the USA (UL) and Canada (cUL).
Maximum Temperature: 650°F
(343°C).
Standard Finish: Plain, Electro-Galvanized, or Hot-Dip Galvanized. Contact customer service for alternative finishes and materials.
Order By: Part number and finish.
Pipe Size Rod Size BCD
Part No. in. (mm) A in. (mm) in. (mm) in. (mm)
B3100-1/2 B3100-3/4
1
/2" (15)
3
/4" (20)
B3100-1 1" (25) B3100-11/4 11/4" (32) B3100-11/2 11/2" (40)
Pipe Hangers
B3100-2 2" (50) B3100-21/2 21/2" (65) B3100-3 3" (80) B3100-31/2 31/2" (90) B3100-4 4" (100) B3100-5 5" (125) B3100-6 6" (150) B3100-8 8" (200)
A
E
D
3
/8"-16 21/8" (54.0) 111/16" (42.9)
3
/8"-16 27/16" (61.9) 17/8" (47.6) 11/8" (28.6)
3
/8"-16 213/16" (71.4) 21/8" (54.0) 13/8" (34.9)
3
/8"-16 37/16" (87.3) 29/16" (65.1) 113/16" (46.0)
3
/8"-16 4" (101.6)` 3" (76.2) 21/4" (57.1)
3
/8"-16 41/2" (114.3) 31/4" (82.5) 21/2" (63.5)
1
/2"-13 59/16" (141.3) 4" (101.6) 31/16" (77.8)
1
/2"-13 63/4" (171.4) 47/8" (123.8) 315/16" (100.0)
1
/2"-13 7" (177.8) 5" (127.0) 41/16" (103.2)
5
/8"-11 713/16"
5
/8"-11 91/16"
3
/4"-10 107/16"
3
/4"-10 123/4"
(198.4)
(230.2)
(265.1)
(323.8)
(Rod Size)
Hanger Rod
Not Included
C
51/2" (139.7) 43/8" (111.1) 61/8" (155.6) 5" (127.0)
615/16" (176.2) 511/16" (144.5)
83/8" (212.7) 71/8" (181.0)
Center of pipe to top of hanger.
Rod Take-Out
Center of pipe to bottom of
hanger rod.
Minimum thread length of
hanger rod
Top of cross bolt to bottom of hanger
B
Adjustment
rod nut inside the hanger.
15
/16" (23.8)
B
C
D
E
F
E Adjustment F Design Load Approx. Wt./100
Part No. in. (mm) in. (mm) Lbs. (kN) Lbs. (kg)
B3100-1/2 21/2" (63.5) B3100-3/4 21/2" (63.5) B3100-1 21/2" (63.5) B3100-11/4 21/2" (63.5)
7
/16" (11.1) 730 (3.25) 25 (11.3)
1
/2" (12.7) 730 (3.25) 29 (13.1)
5
/8" (15.9) 730 (3.25) 35 (15.9)
7
/8" (22.2) 730 (3.25) 40 (18.1)
B3100-11/2 21/2" (63.5) 13/16" (30.2) 730 (3.25) 42 (19.0) B3100-2 21/2" (63.5) 15/8" (41.3) 730 (3.25) 52 (23.6) B3100-21/2 21/2" (63.5) 2" (50.8) 1350 (6.00) 90 (40.8) B3100-3 21/2" (63.5) 2" (50.8) 1350 (6.00) 110 (49.9) B3100-31/2 21/2" (63.5) 2" (50.8) 1350 (6.00) 142 (64.4) B3100-4 21/2" (63.5) 2" (50.8) 1430 B3100-5 21/2" (63.5) 2" (50.8) 1430 B3100-6 3" (76.2) 2" (50.8) 1940 B3100-8 31/2" (88.9) 25/16" (58.7) 2000
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
51
(6.36) 132 (59.9) (6.36) 215 (97.5) (8.63) 320 (145.1) (8.89) 485 (220.0)
B-Line series Pipe Hangers & SupportsEaton
B3100C
B3100F
Loading...