Cooper B-Line B3019 User Manual

B3019 - Adjustable Metal Deck Ceiling Bolt
Size Range:3/8"-16 thru 3/4"-10 rod
Material: Steel
Function: For use in metal deck formed concrete to attach
hanger rods. Allows for pre-positioning of hanger rods in poured concrete decks.
Finish: Plate: Plain Steel. Rod: Electro-Galvanized. Contact Cooper B-Line for alternative finishes and materials.
Order By: Part number and finish. Contact customer service for custom rod lengths.
Thread Thread Approx.
Part No.
B3019-3/8
B3019-1/2
B3019-5/8
B3019-3/4
Size A B Length C D Steel Size Design Load Wt./100
in. (mm) in. (mm) in. (mm) in. (mm) Lbs (kN) Lbs. (kg)
3
/8"-16 21/2" (63.5) 63/8" (161.9) 11/4" (31.7) 7 Ga. x 11/4" x 10" (4.5 x 31.7 x 254.0) 730 (3.25) 80 (36.3)
1
/2"-13 21/2" (63.5) 61/2" (165.1) 11/4" (31.7) 7 Ga. x 11/4" x 10" (4.5 x 31.7 x 254.0) 1350 (6.00) 99 (44.9)
5
/8"-11 21/2" (63.5) 63/4" (171.4) 11/4" (31.7) 7 Ga. x 11/4" x 10" (4.5 x 31.7 x 254.0) 2160 (9.61) 129 (58.5)
3
/4"-10 21/2" (63.5) 63/16" (157.2) 21/4" (57.1)
Concrete Inserts
B
Steel Size
1
/4" x 3" x 10" (6.3 x 76.2 x 254.0) 3230 (14.37) 238 (107.9)
D
D
Underside of anchor bolt
to bottom of plate
Thread Size 'A' with
Thread Length 'C'
Concrete Inserts
B2499 - Concrete Insert
Size Range:5/8"-11 thru 11/2"-6 rod
Material: Steel
Function: Designed to be embedded in concrete to provide
a point of support for
Finish: Plain anchor bolt with Electro-Galvanized coupling. Contact B-Line for alternative finishes and materials.
Note: For rod sizes see page 198.
Order By: Part number and rod size.
1
/8"-7, 11/4"-6, and 11/2"-6 consult factory.
For 1
Part No.
B2499-5/8
B2499-3/4
B2499-7/8
B2499-1 1"-8 3" (76.2) 4" (101.6) 4960 (22.06) 276.0 (125.2)
Consult factory for specifications on rod sizes
5
/8"-11 thru 11/2"-6 rod or bolt sizes .
3
/8"-16 and 1/2"-13, refer to B2501
A
A
3
/16" Dia.
(4.8)
Min. Max. Recommended Loads
Rod Embedment (In 3000 lb.
(13.34kN) Approx.
Size ABHard Rock Concrete) Wt./100
in. (mm) in. (m) lbs. (kN) lbs. (kg)
5
/8"-11 3" (76.2) 31/2" (88.9) 1810 (8.05) 118.0 (53.5)
3
/4"-10 3" (76.2) 31/2" (88.9) 2710 (12.05) 154.0 (69.8)
7
/8"-9 3" (76.2) 4" (101.6) 3770 (16.77) 210.0 (95.3)
11/8"-7, 11/4"-6, and 11/2"-6
B
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
B-Line series Pipe Hangers & Supports
196
Eaton
B2501 - Light Duty Spot Insert - Hanger Application
Size Range:3/8"-16 & 1/2"-13 rod
Material: Steel
Standard Finish: Electro-Plated
3
Approvals: listed in the USA (UL) and Canada (cUL).
Service: Designed to be embedded in concrete for attachment of
3
/8"-16 & 1/2"-13 hanger rods.
Ordering: Specify part number and size.
How to Install: Locate and nail to form. Pour concrete and strip
forms when set. Remove color coded plug, install rod and lock with jam nut.
Note: Design load is based off of rod sizes. Before installation ensure that concrete is sufficient to carry the load.
1
/8" &
2" rod sizes are Underwriters Laboratories
Anchor Bolt ASTM A307
Concrete Inserts
Rod Coupling
Mounting Hole for
Securing to Form
B2501 - Data
UL Listed Approx. Wt./C
Part No. Rod Size Lbs. (kg)
B2501-3/8
B2501-1/2
3
/8"-16 Up to 4” IPS 22 (10.0)
1
/2"-13 Up to 8” IPS 26 (11.8)
Concrete Inserts
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
B-Line series Pipe Hangers & Supports
198
Eaton
Concrete Inserts
B2500 - Light Duty Spot Insert
Material: Steel
Function: Designed to be embedded in concrete to attach
7
/8"-9 hanger rods.
How to Install: Attach concrete insert to forms and install reinforcing rods as required. After forms are dismantled, the knockout can be removed from the insert. The N2500 insert nut can be installed and the rod fastened to the nut. The rod should touch the inside top of the insert but should not be forced further to avoid damaging the insert.
Approvals: Underwriters Laboratories Listed for maximum pipe size 6"
(150). Conforms to Federal Specification WW-H-171E &
A-A-1192A, Type 19 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 18.
Weight: Approx. Wt./100 - 46 Lbs.
(20.8kg)
Finish: Electro-Galvanized.
Order By: Part number and finish.
Concrete Inserts
(Order N2500 nuts separately).
Design Load: Loading based on a straight pull of 600 Lbs.
Note: Before installation ensure that concrete is sufficient to
carry the load.
1
/4"-20 to
(2.67kN).
2"
(50.8)
11/2"
(38.1)
Material Thickness
12 Gauge
1
/4"
3
(82.5)
Hanger Rod and
Nut Not Included
(2.6)
19/16"
(39.7)
N2500 - Steel Insert Nut
Size Range:1/4"-20 through 7/8"-9.
Material: Steel
Function: Designed for use with B2500 spot insert.
Finish: Plain or Electro-Galvanized.
Order By: Part number and size.
Part No. A
N2500-1/4
N2500-3/8
N2500-1/2
N2500-5/8
N2500-3/4
N2500-7/8
Tap Size Approx. Wt./100
Lbs. (kg)
1
/4"-20 14 (6.3)
3
/8"-16 13 (5.9)
1
/2"-13 12 (5.4)
5
/8"-11 11 (5.0)
3
/4"-10 11 (5.0)
7
/8"-9 10 (4.5)
11/4"
(31.7)
11/4"
(31.7)
5
/16"
(7.9)
A
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Eaton B-Line series Pipe Hangers & Supports
199
Concrete Inserts
B3014 - Malleable Iron Insert
Material: Malleable Iron
Function: Designed to be embedded in concrete to attach
7
/8"-9 hanger rods.
How to Install: Attach concrete insert to forms and install reinforcing rods as required. After forms are dismantled, the B3014N nut can be installed and the rod fastened to the nut. The rod should touch the inside top of the insert.
Approvals: Underwriters Laboratories Listed when used with B3014N Insert Nut. Conforms to Federal Specification WW-H-171E & A-A-1192A, Type 18 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 18.
Weight: Approx. Wt./100 - 166 Lbs.
(75.3kg)
Finish: Plain or Electro-Galvanized.
Order By: Part number and finish.
(Order B3014N nuts separately).
Design Load: Design Loads based on B3014N malleable iron insert nut below.
Note: Before installation ensure that concrete is sufficient to carry the load.
3
/8"-16 to
2"
(50.8)
13
/16"
(20.6)
21/4"
(57.1)
Horizontal Adjustment:
3
For
/8"-16, 1/2"-13, 5/8"-11 rods - Adjustment is 13/4" (44.4)
For3/4"-10, 7/8"-9 rods - Adjustment is 13/16" (30.2)
33/8"
(85.7)
31/4"
(82.5)
Concrete Inserts
B3014N - Malleable Iron Insert Nut
Size Range:3/8"-20 through 7/8"-9.
Material: Malleable Iron
Standard Finish: Plain or Electro-Galvanized
Service: Designed for use with the B3014 malleable
iron insert shown above.
Ordering: Part number and finish.
Tap Size UL Max. Design Load* Approx. Wt./100
Part No. 'A' Pipe Size
B3014N-3/8
B3014N-1/2
B3014N-5/8
B3014N-3/4
B3014N-7/8
3
/8"-16 4” 730 (3.25) 22 (10.0)
1
/2"-13 8” 1350 (6.00) 22 (10.0)
5
/8"-11 10” 1400 (6.23) 20 (9.1)
3
/4"-10 10” 1400 (6.23) 29 (13.1)
7
/8"-9 10” 1400 (6.23) 29 (13.1)
11/4"
(31.7)
17/8"
(47.6)
Lbs. (kN) Lbs. (kg)
1
/2"
(12.7)
For 3/8"-16 thru
5
/8"-11 Tap Sizes 'A'
15/8"
(41.3)
17/8"
(47.6)
1
/2"
(12.7)
For 3/4"-10 &
7
/8"-9 Tap Size 'A'
* When used with B3014 Malleable Iron Insert.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
B-Line series Pipe Hangers & Supports
200
Eaton
Concrete Inserts
B2505 thru B2508 - Spot Insert
Material: Steel (Stainless steel available on B2505 only)
Standard Finish: Plain or Pre-Galvanized
Function: Designed to be embedded in concrete to attach
7
/8"-9 hanger rods.
How to Install: Attach concrete insert to forms and install reinforcing rods as required. After forms are dismantled, the channel nut can be installed and the rod fastened to the nut. The rod should touch the inside top of the insert.
Approvals: Underwriters Laboratories Listed. Conforms to Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 18.
Order By: Part number and finish. When supporting 10"
(254mm) pipe, order B2505 Insert with
Note:
For appropriate channel nut selection, see page 17.
installation ensure that concrete is sufficient to carry the load.
Concrete Inserts
5
/8"-11 channel nuts.
1
/4"-20 to
Before
5
2
/8"
(66.7)
End Caps
Channel
Size
51/16"
(128.6)
Styrofoam Filled
B2506 shown
Channel End Cap Design Load Max. Pipe Size Approx. Wt./100
Part No. Size Part No. Lbs. (kN) in. (mm) Lbs. (kg)
B2505 B22 B3322 1200 (5.34) 10" (250) 96 (43.5)
B2506 B32 B3332 1000 (4.45) 8" (200) 88 (39.9)
B2507 B42 B3342 1000 (4.45) 8" (200) 77 (34.9)
B2508 B52 B3352 1000 (4.45) 8" (200) 69 (31.3)
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Eaton B-Line series Pipe Hangers & Supports
201
B2503 - Heavy Duty Spot Insert
Material: Steel
Standard Finish: Electro-Galvanized
Function: Designed to be embedded in concrete where heavy loads
are required in curtain wall applications. Styrofoam end caps prevent concrete seepage into the channel.
How to Install: Attach concrete insert to forms and install reinforcing rods as required. After forms are dismantled, the channel nut can be installed and the rod fastened to the nut. The rod should touch the inside top of the insert.
Approvals: Conforms to Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 18.
Design Load: 5000 Lbs. Loading based on two N225 channel nuts spaced 3” (76.2mm) on center and a minimum of 2”
Weight: Approx. Wt./100 - 42 Lbs.
Order By: Part number and finish. Channel nuts are sold
separately, see page 17 for appropriate selection.
(22.2kN).
(50.8mm) from the end of the insert.
(19.0kg)
Concrete Inserts
5
/32" (4.0)
Dia. Nail Holes
2"
(50.8)
12"
(304.8)
8"
(203.2)
Styrofoam
End Caps
Concrete Inserts
51/2"
(139.7)
15/8"
(41.3)
15/8"
(41.3)
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
B-Line series Pipe Hangers & Supports
202
Eaton
Loading...