Pipe Hangers
Fig. 200 - “Trimline” Adjustable Band Hanger (B-Line Fig. B3170NF)
Fig. 200F - “Trimline” Adjustable Band Hanger with Felt Lining (B-Line Fig. B3170NFF)
Fig. 200C - “Trimline” Adjustable Band Hanger with Plastic Coated (B-Line Fig. B3170NFC)
Fig. 200S - “Trimline” Adjustable Band Hanger with Non-Captured Nut
Size Range:
1
Fig. 200 -
/2” (15mm) thru 8” (200mm) pipe
Material: Steel, Pre-Galvanized to G90 specifications
Function: For fire sprinkler and other general piping purposes. Knurled
swivel nut design permits hanger adjustment after installation.
Features:
1
•(
/2” (15mm) thru 2” (50mm)) Flared edges ease installation for all pipe
types and protect CPVC plastic pipe from abrasion. Captured design
keeps adjusting nut from separating with hanger. Hanger is easily
installed around pipe.
For hanger with non-captured nut order Fig. 200S.
1
/2” (65mm) thru 8” (200mm)) Spring tension on nut holds it securely in
• (2
hanger before installation. Adjusting nut is easily removed.
Approvals: Underwriters Laboratories listed (
1
/2” (15mm) thru 8” (200mm))
in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and
3
Factory Mutual Engineering Approved (FM) (
/4” (20mm) thru 8” (200mm)).
Conforms to Federal Specifications WW-H-171E & A-A-1192A, Type 10
and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58,
Type 10.
Maximum Temperature: 650°F
(343°C)
Finish: Pre-Galvanized. Stainless Steel
materials will be supplied with (2) hex nuts
in place of a knurl nut.
Order By: Figure number and pipe size
Fig. 200-1 to 200-2
B
A
Fig. 200-1/2. 200-3/4
1
Fig. 200-2
/2 to 200-8
Designed to meet or exceed requirements of
FM DS 2-0.
Pipe Size Rod Size ABApprox. Wt./100
Part No.
200-1/2
200-3/4
200-1 1" (25)
200-11/4 11/4" (32)
200-11/2 11/2" (40)
200-2 2" (50)
200-21/2 21/2" (65)
200-3 3" (75)
200-31/2 31/2" (90)
200-4 4" (100)
200-5 5" (125)
200-6 6" (150)
200-8 8" (200)
in. (mm) in. (mm) in. (mm) lbs. (kg)
1
/2" (15)
3
/4" (20)
3
/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0)
3
/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0)
3
/8"-16 33/8" (85.7) 25/8" (66.7) 12 (5.5)
3
/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9)
3
/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4)
3
/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9)
3
/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3)
3
/8"-16 57/8" (149.1) 4" (101.6) 29 (13.3)
3
/8"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6)
3
/8"-16 73/8" (187.3) 5" (127.0) 35 (16.0)
1
/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2)
1
/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4)
1
/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3)
Fig. 200C
Fig. 200F
Fig. 200
Fig. 200S
Pipe Hangers
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Fire Protection Solutions
21
Pipe Hangers
Fig. 2 - Adjustable Band Hanger (B-Line B3170)
Fig. 2F - Adjustable Band Hanger Felt Lined for Copper Tubing (B-Line B3170F)
Size Range:
1
Fig. 2 - 2
Fig. 2F - 2
/2” (65mm) thru 6” (150mm) pipe
1
/2” (65mm) thru 6” (150mm) pipe
Material: Pre-Galvanized Steel
Function: Recommended for the suspension of non-
insulated pipe or insulated pipe with B3151 shield.
Fig. 2NFPA accomodates the reduced rod schedule of
the National Fire Pretection Association Pamphlet 13.
Approvals: Factory Mutual Engineering Approved.
Underwriters Laboratories Listed. Conforms to Federal
Specification WW-H-171E & A-A-1192A Type 10 and
Manufacturers Standardization Society ANSI/MSS
SP-69 & SP-58, Type 10.
Standard Finish: Pre-Galvanized
Note: Available in Stainless Steel material.
Order By: Part number and finish.
C
B
D
Fig. 2
C
B
D
Fig. 2F
Pipe Hangers
Fig. 2
Nominal Pipe Size Rod Size BCDMax. Rec. Load Approx Wt./100
Part No.
2-21/2 21/2" (65)
2-3 3" (75)
2-31/2 31/2" (90)
2-4 4" (100)
2-5 5" (125)
2-6 6" (150)
in. (mm) A in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg)
1
/2"-13 * 53/4" (146.0) 41/4" (107.9) 15/8" (41.3) 600 (2.67) 41 (18.6)
1
/2"-13 * 6" (152.4) 41/8" (104.8) 11/4" (31.7) 600 (2.67) 45 (20.4)
1
/2"-13 * 73/8" (187.3) 51/4" (133.3) 21/8" (54.0) 600 (2.67) 52 (23.6)
5
/8"-11 * 73/8" (187.3) 5" (127.0) 15/8" (41.3) 1000 (4.45) 59 (27.6)
5
/8"-11 ** 9" (228.6) 61/8" (155.6) 21/4" (57.1) 1250 (5.56) 97 (44.0)
3
/4"-10 ** 93/8" (238.1) 61/2" (165.1) 17/8" (47.6) 1250 (5.56) 139 (63.0)
Fig. 2F
Nominal Pipe Size Rod Size BCDMax. Rec. Load Approx Wt./100
Part No.
2F-21/2 21/2" (65)
2F-3 3" (75)
2F-31/2 31/2" (90)
2F-4 4" (100)
2F-5 5" (125)
2F-6 6" (150)
in. (mm) A in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg)
1
/2"-13 * 53/4" (146.0) 41/4" (107.9) 15/8" (41.3) 600 (2.67) 41 (18.6)
1
/2"-13 * 6" (152.4) 41/8" (104.8) 11/4" (31.7) 600 (2.67) 45 (20.4)
1
/2"-13 * 73/8" (187.3) 51/4" (133.3) 21/8" (54.0) 600 (2.67) 52 (23.6)
5
/8"-11 * 73/8" (187.3) 5" (127.0) 15/8" (41.3) 1000 (4.45) 59 (27.6)
5
/8"-11 ** 9" (228.6) 61/8" (155.6) 21/4" (57.1) 1250 (5.56) 97 (44.0)
3
/4"-10 ** 93/8" (238.1) 61/2" (165.1) 17/8" (47.6) 1250 (5.56) 139 (63.0)
* 3/8 nut is used when requested. ** 1/2 nut is used when requested.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
22
Fire Protection Solutions