Function: Used as a spacer at a seismic brace location to
keep clevis hanger from collapsing during seismic event.
Approvals: Included in our Seismic Restraints Catalog
approved by the State of California Office of Statewide
Health Planning and Development (OSHPD). For additional
load, spacing and placement information relating to OSHPD
projects, please refer to our Seismic Restraint
Systems Guidelines.
Installation Note: Fig. 1CBS fits easily over the cross bolt
and attaches by pinching tabs down.
Finish: Pre-Galvanized. Contact B-Line for alternative finishes
and materials.
Attachments
Order By:
Pipe Size Approx. Wt./100
Part No. in. (mm) lbs. (kg)
Seismic System
Figure
number and finish.
1CBS-1 1”
1CBS-11/4 11/4” (32) 4.1 (1.8)
1CBS-11/2 11/2” (40) 4.8 (2.2)
1CBS-2 2” (50) 9.4 (4.2)
1CBS-21/2 21/2” (65) 11.4 (5.2)
1CBS-3 3” (75) 13.9 (6.8)
1CBS-31/2 31/2” (90) 16.0 (7.2)
1CBS-4 4” (100) 18.0 (8.1)
1CBS-5 5” (125) 27.3 (12.4)
1CBS-6 6” (150) 32.5 (14.7)
1CBS-8 8” (200) 42.5 (19.2)
1CBS-10 10” (250) 72.7 (32.9)
1CBS-12 12” (300) 86.3 (39.1)
1CBS-14 14” (350) 157.6 (71.5)
1CBS-16 16” (400) 183.7 (83.3)
1CBS-18 18” (450) 224.6 (101.9)
1CBS-20 20” (500) 254.0 (115.2)
(25) 3.2 (1.4)
Component of State of
California OSHPD Approved
Seismic Restraints System
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
51
Seismic Bracing Products
Fig. 120RWA - (Model B) Retrofit Wrap Around “U” Hanger Clamp
Size Range: 1" (25mm) thru 8" (200mm) pipe
Material: Steel
Function: Designed to restrain movement of the pipe within standard
U-hangers as required by NFPA 13. Where retrofit capability is crucial, the
Fig. 120RWA is a labor efficient alternative to the standard B-Line Fig. 120W
wrap around U-hanger.
Features Installs easily by tightening two hex nuts. Features a unique
bracing slot that locks onto a standard U-hanger to become a solid unit that
will stabilize the pipe during seismic activity or sprinkler head activation.
Designed to be used in retrofit or new construction applications. Will clamp
to existing U-Hangers without restriction to leg angle.
Approvals: Underwriters Laboratories listed in the USA (UL) and Canada
(cUL) as a restrainer. Included in our Seismic Restraints Catalog approved by
the State of California Office of Statewide Health Planning and Development
(OSHPD). For additional load, spacing and placement information relating to
OSHPD projects, please refer to our Seismic Restraint Systems Guidelines.
NFPA 13 (2010) 9.3.6.3.
Finish: Plain and Galvanized. Contact B-Line for alternative finishes and
materials.
Order By: Figure number, type numbers and pipe size
Ordering Note: Order by the following type and pipe size:
Type 1 — (1"
Type 2 — (1
(25mm) and 1
1
⁄2" (40mm) and 2" (50mm) pipe size)
1
⁄4" (32mm) pipe size)
Type 3 — (21⁄2" (65mm) and 3" (80mm) pipe size)
Type 4 — (4" (100mm) pipe size)
Type 6 — (5" (125mm) and 6" (150mm) pipe size)
Type 8 — (8"
(200mm) pipe size)
Component of State of
California OSHPD Approved
Seismic Restraints System
Important Note: The bracing slot feature is sized to fit the U-Hanger rod
schedule as required by NFPA 13 as follows:
5
⁄16" (7.9mm) rod for up to 2" (50mm) pipe
3
⁄8" (9.5mm) rod for 21/2" (65mm) - 6" (160mm) pipe
1
⁄2" (12.7mm) rod for 8" (200mm) pipe
For other rod size requirements consult factory.
Type Pipe Size
Part No.
in. (mm)
120RWA-TYPE1-1 1 1" (20)
120RWA-TYPE1-1
120RWA-TYPE2-11/2
1
/4
1 11/4
2 11/2
" (25)
" (40)
120RWA-TYPE2-2 2 2" (50)
120RWA-TYPE3-21/2
3 21/2
" (65)
120RWA-TYPE3-3 3 3" (80)
120RWA-TYPE4-31/2
4 31/2
" (90)
120RWA-TYPE4-4 4 4" (100)
120RWA-TYPE6-5 6 5" (125)
120RWA-TYPE6-6 6 6" (150)
120RWA-TYPE8-8 8 8" (200)
Attachments
Seismic System
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Seismic Bracing Products
52
Seismic System Attachments
Fig. 25 - Surge Restrainer
Size Range: — One size fits 3⁄4"
Material: — Pre-Galvanized Steel
Function: — Designed to be used in conjunction with Fig. 200 band hangers
to restrict the upward movement of piping as it occurs during sprinkler head
activation or earthquake type activity. The surge restrainer is easily and
efficiently installed by snapping into a locking position on the band hanger.
This product is intended to satisfy the requirements as indicated in the National
Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4
Can be used to restrain either steel pipe or CPVC plastic Pipe.
Approvals: — Underwriters Laboratories Listed only when used with band
hanger Fig. 200, in the USA (UL) and Canada (cUL).
Finish: Pre-Galvanized
Order By: Figure number and band hanger, size from
3
⁄4"
(20mm)
thru 2"
(40mm)
Patent #5,344,108
(20mm)
thru 2"
(40mm)
pipe.
.
Seismic System
Attachments
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
53
Seismic Bracing Products
Fig. 98 - Rod Stiffener
Fig. 98B - Rod Stiffener with Break-Off Bolt Head
Size Range: Secures 3⁄8"-16 thru 7⁄8"-9 hanger rod
Material: Steel
Function: Secures channel to hanger rod for vertical seismic bracing.
Approvals: Included in our Seismic Restraints Catalog approved
by the State of California Office of Statewide Health Planning and
Development (OSHPD). For additional load, spacing and placement
information relating to OSHPD projects, please refer to our Seismic Restraint
Systems Guidelines
Finish: Electro Galvanized. Contact B-Line for alternative finishes and materials.
Component of State of
California OSHPD Approved
Seismic Restraints System
Fig. 98
Weight: Approx. Wt./100: Fig. 98 - 11.8 Lbs.
(5.3kg)
Fig. 98B - 12.7 Lbs. (5.7kg)
Order By: Figure number
Fig. SC228 - Hanger Rod Stiffener
Size Range: Secures 3⁄8"-16 thru 5⁄8"-11 hanger rod
Material: Steel
Function: Secures channel to hanger rod for vertical seismic bracing.
Finish: Electro Galvanized. B-Line for alternative finishes
Weight: Approx. Wt./100: 21.0 Lbs.
Order By: Figure part number
Note: Order channel separately
Slight distortion of the channel (strut) may occur upon
installation of rod stiffeners.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Seismic Bracing Products
54
Notes:
1.) Rod stiffeners are required only on hanger and
trapeze assemblies that have seismic bracing
attached at or within 4” (101.6mm) of the rod.
A minimum of two rod stiffeners (Figure 98, 98B,
or SC228) must be installed.
2.) Recommended torque on Figure 98 and SC228
is 8 ft-lbs. (10.8Nm) or finger tight and one full
turn with a wrench.
Figure 98B has the break off bolt head.
Seismic System Attachments
Fig. 4A - Pipe Clamp for Sway Bracing
Size Range: 4"
4"
(100mm)
Material: Steel
Function: For bracing pipe against sway and seismic disturbance.
Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada
(cUL) 4"
approved by the State of California Office of Statewide Health Planning and
Development (OSHPD).
Installation Instructions: Fig. 4A is the "braced pipe" attachment component
of a longitudinal or riser brace assembly. It is intended to be combined with the
"bracing pipe" and our transitional and structural attachment component(s) to
form a complete bracing assembly.
NFPA 13 and/or OSHPD guidelines should be followed.
To Install: Place the Fig. 4A over the pipe to be braced. Attach our transitional
fitting, either Fig. 980, 910 or 909, to the clamp ears. Tighten bolts and nuts;
torque requirement is a minimum of 50 ft./lbs.
Transitional fitting attachment can pivot for adjustment to proper brace angle.
Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and
materials.
Order By: Figure number, pipe size and finish
use B3140.
(100mm)
(100mm)
thru 8"
thru 8"
(200mm)
(200mm)
pipe. For sizes smaller than
. Included in our Seismic Restraints Catalog
(68Nm)
per MSS-SP-58 (2009).
Component of State of
California OSHPD Approved
Seismic Restraints System
A
D
C
HHCS and Hex Nuts Included
Seismic System
Attachments
Fig. 4A - Longitudinal
Brace
Pipe Max. Horizontal Approx.
Part Size A C D Bolt Design Load (UL) Wt./100
No. in. (mm) in. (mm) in. (mm) in. (mm)Sizelbs. (kN) lbs. (kg)
Eaton’s B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components,
resulting in a listed seismic bracing assembly. B-Line’s warranty for seismic bracing components will be the warranty provided in
B-Line’s standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from
B-Line’s warranty, Eaton’s B-line Business makes no warranty relating to B-Line’s seismic bracing components that are combined
with products not provided by Eaton’s B-Line Business.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
55
Seismic Bracing Products
Figure 4B Pipe Clamp for Sway Bracing (Cooper B-Line B386)
Size Range:3⁄4” (20mm) to 8” (200mm) pipe
Material: Steel
Function: For bracing pipe against sway and seismic disturbance
Approvals: Included in the Seismic Restraints Catalog approved by the Stateof California Office of Statewide Health Planning and Development (OSHPD).
Standard Finish: Plain or Electro-Plated, Contact B-Line for alternative
finishes and materials.
Ordering: Specify part number and finish.
Installation Instructions: Fig. 4B is the “braced pipe” attachment
component of a longitudinal or lateral sway brace assembly. It is intended
to be combined with the “bracing pipe” and transitional and structural
attachment component(s) to form a complete bracing assembly.
NFPA 13 and/or OSHPD guidelines should be followed.
To Install: Place the Fig. 4B over the pipe to be braced. Attach other
transitional fitting, Fig. 909, 910, or 980. Tighten bolts and nuts. Transitional
fitting attachment can pivot for adjustment to proper brace angle.
Component of State of
California OSHPD Approved
Seismic Restraints System
C
A
B
D
Shown with two Cooper B-Line
Fig. 980’s and Schedule 40 brace
pipe.
Hanger/Longitudinal Brace
Pipe Size Rod Size B C D Bolt Size Design Load
Fig. 4B
Approx. Wt./100
Part No. in. (mm) A in. (mm) in. (mm) in. (mm) Lbs. (kN) Lbs. (kg)
Eaton’s B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components,
resulting in a listed seismic bracing assembly. B-Line’s warranty for seismic bracing components will be the warranty provided in
B-Line’s standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from
B-Line’s warranty, Eaton’s B-line Business makes no warranty relating to B-Line’s seismic bracing components that are combined
with products not provided by Eaton’s B-Line Business.
Attachments
Seismic System
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Seismic Bracing Products
56
Seismic System Attachments
Fig. 4LA - “In-Line” Sway Brace Attachment
Size Range: 1" (25mm) through 12" (300mm) IPS.
Material: Steel
Function: For bracing pipe against sway and seismic disturbance.
Approvals: Approved by Factory Mutual Engineering (FM), 1"
12" (300mm) pipe.
Installation Instructions: Fig. 4LA can be used as the system attachment
component of a longitudinal or lateral brace assembly. It is intended to be
combined with the "bracing member" and our transitional attachment and
structural attachment to form a complete bracing assembly.
NFPA 13, FM DS 2-8, and/or OSHPD guidelines should be followed.
To Install: Place the Fig. 4LA pipe clamp component over the pipe to be
braced and tighten down the break-off nuts until the hex head portion breaks
off to verify correct installation torque. Next engage brace member (pipe or
strut) with jaw component and tighten break-off head bolt
until the hex head breaks off to verify correct installation torque.
Pivot jaw for correct angle and attach to structure using
our brand transitional attachment and structural attachment.
Finish: Plain or Electro-Galvanized. Contact B-Line for
alternative finishes and materials.
Eaton’s B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components,
resulting in a listed seismic bracing assembly. B-Line’s warranty for seismic bracing components will be the warranty provided in
B-Line’s standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from
B-Line’s warranty, Eaton’s B-line Business makes no warranty relating to B-Line’s seismic bracing components that are combined
with products not provided by Eaton’s B-Line Business.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Eaton’s B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components,
resulting in a listed seismic bracing assembly. B-Line’s warranty for seismic bracing components will be the warranty provided in
B-Line’s standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from
B-Line’s warranty, Eaton’s B-line Business makes no warranty relating to B-Line’s seismic bracing components that are combined
with products not provided by Eaton’s B-Line Business.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Seismic Bracing Products
58
Attachments
Seismic System
Seismic System Attachments
Fig. 4L - “In-Line” Sway Brace Attachment
Size Range: 21/2" (65mm) through 8" (200mm) ips.
Material: Steel
Function: For bracing pipe against sway and seismic disturbance.
Approvals: Underwriters Laboratories Listed in the USA (UL) and
Canada (cUL) 2
Engineering (FM), 2
Installation Instructions: Fig. 4L is the "braced pipe" attachment
component of a longitudinal or 4-way sway brace assembly. It is intended to be
combined with the "bracing pipe" and our structural attachment component to
form a complete bracing assembly.
NFPA 13, FM DS 2-8, and/or OSHPD guidelines should be followed.
To Install: Place the Fig. 4L over the pipe to be braced and tighten
bolts. Then engage "bracing pipe" into jaw opening and tighten set screw
until head snaps off. Jaw attachment can pivot for adjustment to proper
brace angle.
Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and
materials.
Order By: Figure number, pipe size and finish.
1
/2" (65mm) through 8" (200mm) pipe. Approved by Factory Mutual
1
/2" (65mm) through 8" (200mm) pipe.
Set Screw & Hardware
Included
D
C
Component of State of
California OSHPD Approved
Seismic Restraints System
A
Longitudinal
Brace
4-Way Riser Brace
(plan view)
Seismic System
Attachments
Pipe Max. Horizontal Approx.
Part Size A C D Bolt Size Design Load (cULuc) Wt./100
No.
4L-21/2
4L-3 3" (80) 7" (177.8) 23/4
4L-4 4" (100) 81/2
4L-5 5" (125) 93/4
4L-6 6" (150) 111/2
4L-8 8" (200) 131/4
Pipe
in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg)
Eaton’s B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components,
resulting in a listed seismic bracing assembly. B-Line’s warranty for seismic bracing components will be the warranty provided in
B-Line’s standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from
B-Line’s warranty, Eaton’s B-line Business makes no warranty relating to B-Line’s seismic bracing components that are combined
with products not provided by Eaton’s B-Line Business.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
59
Seismic Bracing Products
Fig. 907 - 4-Way Sway Brace Attachment
Size Range: 1"
1
1
/4"
(25.4mm)
Material: Steel, hardened cone (or cup) point set screw
Function: For bracing pipe against sway and seismic disturbances, Functions
as a longitudinal brace connection when attached to a lateral brace pipe. Bracing
connection must be positioned as close as physically possible to the braced pipe
(No more than 3"
components. When used in conjunction with Fig. 1000, this combination bracing
restricts piping movement in tension and compression both laterally and
longitudinally.
Approvals: Included in our Seismic Restraints Catalog approved by the State
of California Office of Statewide Health Planning and Development (OSHPD). For
additional load, spacing and placement information relating to OSHPD projects,
please refer to our Seismic Restraint Systems Guidelines.
Installation Instructions: Fig. 907 is a transitional component of a longitudinal
4-way sway brace assembly. It is intended to be installed with the longitudinal and
lateral "bracing pipes", our structural attachment fittings, Fig. 909, 910 and 980 and
the Fig. 1000 our "braced pipe" fitting, to form a complete bracing assembly.
NFPA 13 and/or OSHPD guidelines should be followed.
To Install: Attach the Fig. 907 over the lateral "bracing pipe" to within 3"
of its position relative to the "braced pipe" connection. Adjust brace angle and
tighten set screws until the heads bottom out on surface.
Finish: Plain. Contact B-Line for alternative finishes and materials.
Order By: Figure number, bracing pipe sizes and finish.
(25.4mm)
x 11/4"
(76.2mm)
x 1"
(25.4mm)
(25.4mm)
bracing pipe.
, 1"
(25.4mm)
x 11/4"
(31.7mm)
and
away). Must be used only with B-Line/TOLCO bracing
(76.2mm)
Component of State of
California OSHPD Approved
Seismic Restraints System
A
B
Set Screws
Included
Shown
With
Fig. 909
Fig. 1000
Fig. 907 Can Be Attached On Either
Side Of The Pipe Being Braced
4-Way Riser Brace
Part Number Brace Pipe Size A B Max. Design Load Approx. Wt./100
in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg)
3
907-1 X 1 1” x 1” (25 x 25) 43/4
907-1 X 11/4
907-11/4
* Load will accommodate up to 4”
Eaton’s B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components,
resulting in a listed seismic bracing assembly. B-Line’s warranty for seismic bracing components will be the warranty provided in
B-Line’s standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from
B-Line’s warranty, Eaton’s B-line Business makes no warranty relating to B-Line’s seismic bracing components that are combined
with products not provided by Eaton’s B-Line Business.
1” x 11/4
X 11/4
11/4
” (25 x 32) 53/16
” x 11/4
” (32 x 32) 53/8
(100mm) pipe at maximum spacing.
” (120.6)
” (128.6)
” (136.5)
4
/4
” (120.6) 655* (2.91) 103 (46.7)
13
4
/16
” (122.2) 655* (2.91) 107 (48.5)
1
5
/4
” (133.1) 655* (2.91) 109 (49.4)
Fig. 907
Shown
With
Fig. 980
Attachments
Seismic System
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Size Range: Fits bracing pipe 1" (25mm) thru 2" (50mm), 12 gauge (2.6mm)
channel and all structural steel up to 1/4" (6.3mm) thick.
Fig. 981-S fits rod sizes
Fig. 981-L fits rod sizes
Material: Steel
Function: Multi-functional attachment to hanger rod, trapeze rod, structure or braced
pipe fitting.
Features: Fits multiple sizes of bracing pipe, strut or structural steel. Swivel
allows adjustment to various surface angles. Breakaway bolt heads assure verification
of proper installation torque. Unique "fast attach" yoke design fits multiple rod sizes;
3
/8" thru 5/8" and 3/4" thru 7/8". “Stackable” design allows installation of both lateral and
longitudinal braces to be easily installed on a single hanger rod, with no disassembly.
Installation: Fig. 981 is the “braced pipe” attachment component of a lateral
or longitudinal brace assembly. It is intended to be combined with the pipe hanger,
all-thread rod, “bracing pipe” and our transitional and structural attachment
component(s) to form a complete bracing assembly.
NFPA 13 and/or OSHPD guidelines should be followed.
To Install: Spin nut on top of hanger counterclockwise to loosen the nut and raise it
above the top of the hanger. Attach Fig. 981 by slipping the open side of the 981 yoke
onto the all thread rod above the top of the hanger. Tighten
on yoke until head breaks-off to ensure proper installation torque. Spin the hex nut
clockwise and tighten securely. Insert brace pipe into the jaw of the 981 and tighten
the cone point set screw until the head breaks off ensuring proper installation torque.
Pivot brace pipe to proper angle and attach to structure using our swivel structural
attachment.
Approvals: Included in our Seismic Restraint Systems Guidelines, approved by
the California Office of Statewide Health Planning and Development (OSHPD).
For additional load, spacing and placement information relating to OSHPD
projects, please refer to our Seismic Restraint Systems Guidelines.
Size Range: Fig. 985-S fits rod sizes 3/8” thru 5/8”
3
Fig. 985-L fits rod sizes
/4” thru 7/8” rod sizes
Material: Steel
Function: Used for attachment of seismic bracing to pipe hanger or trapeze
Features:
• Allows up to 12”
(304.8mm)
of adjustability in brace length, when used
with Fig. 986
• Break-off set screw heads visually verify required installation torque
• Unique “Fast Attach” yoke design allows Fig. 985 to be installed to hanger
rods
3
/8” thru 5/8” or 3/4” thru 7/8”
Finish: Electro-galvanized
Order By: Figure number, rod size & finish
Patent Pending
B
A
Rod Size
Set Screws
Included
Part Rod Max. Horizontal Approx.
Number Size A B Design Load Wt./100
in. (mm) in. (mm) lbs. (kN) lbs. (kg)
985-S 3/8” thru 5/8”
985-L 3/4” & 7/8”
Fig. 986
Structural Attachment
6”
2” (50.8) 11/2” (38.1) 2015 (8.96) 204 (92.5)
2” (50.8) 15/8” (41.3) 2015 (8.96) 198 (89.8)
Max.
(152.4mm)
15/8” (41.3mm) x 15/8” (41.3mm) 12
Ga. (2.6mm) Channel (Typ.)
Fig. 985
Hanger or Trapeze Attachment
Max.
6” (152.4mm)
Attachments
Seismic System
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Seismic Bracing Products
62
Seismic System Attachments
Fig. 991 - Fast Attach – Cable Sway Brace Attachment
Component of State of
California OSHPD Approved
Seismic Restraints System
Size Range:1/8”, 3/16” and 1/4” pre-stretched cable.
Fig. 991S fits rod sizes 3⁄8" thru 5⁄8".
3
Fig. 991L fits rod sizes
⁄4" thru 7⁄8".
Material: Steel
Function: Cable attachment for sway bracing. Attaches sway brace to hanger rod. To be
used with 7 x 19 strand core pre-stretched galvanized aircraft cable.
Features: Cable easily slides into oversized front arch opening. Swivel allows adjustment
to various surface angles. Break-away hex nuts assure verification of proper installation
torque. Unique “Fast-Attach” yoke design fits multiple rod sizes;
To verify proper installation to hanger rod, simply install yoke to hanger rod and tighten
3
/8” thru 5/8” or 3/4” thru 7/8”.
3
/8”
cone point set screw until head breaks off. “Stackable” design allows installation of both
lateral and longitudinal braces, as well as opposing braces, to be easily installed on a single
hanger rod, with no disassembly. The retrofit yoke has a visual verification of proper
installation torque. Tighten existing hex nut down until the slight gap in the yoke assembly
closes completely.
Approvals: Included in our Seismic Restraints Catalog approved by the State of California
Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing
and placement information relating to OSHPD projects, please refer to our Seismic Restraint
System Guidelines.
Part Rod Cable Max. Horizontal Approx.
Number Sizes Diameter A B Design Load* Wt./100
in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg)
991-S-1/8
Seismic System
Attachments
991-S-3/16 thru 3/16” (4.8)
991-S-1/4
3
/8”
5
/8”
/8” (3.2)
1
/4” (6.3)
1
5
4
/16” (14.3) 2” (50.8) 975 (4.33) 128.3 (58.2)
5”
(127.0) 2
5”
(127.0) 2
1
/4” (57.1) 2050 (9.12) 182.1 (82.6)
5
/8” (66.7) 3150 (14.01) 221.1 (100.3)
Part Rod Cable Max. Horizontal Approx.
Number Sizes Diameter A B Design Load* Wt./100
in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg)
991-L-1/8
3
/4”
/8” (3.2)
1
991-L-3/16 & 3/16” (4.8)
7
991-L-1/4
* Maximum load rating controlled by cable breaking strength.
/8”
1
/4” (6.3)
5
4
/16” (14.3) 2” (50.8) 975 (4.33) 122.3 (55.5)
5”
(127.0) 2
5”
(127.0) 2
1
/4” (57.1) 2050 (9.12) 176.1 (79.9)
5
/8” (66.7) 3150 (14.01) 215.1 (97.5)
B
A
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
63
Seismic Bracing Products
Fig. 1000 - “Fast Clamp” Sway Brace Attachment
Size Range: Pipe size to be braced: 1"
(25mm)
thru 6"
(150mm)
Schedule 10
Component of State of
California OSHPD Approved
Seismic Restraints System
thru 40 IPS.
Pipe size used for bracing: 1"
(25mm)
and 11⁄4"
(32mm)
Schedule 40 IPS.
Material: Steel
Function: A restraint device intended for lateral bracing.
Features: Field adjustable, making critical pre-engineering of bracing pipe unnecessary.
Unique design requires no threading of bracing pipe. Can be used as a component of a
4-way riser brace. Can be used as longitudinal brace with Fig. 907. Steel leaf spring insert
provided to assure installer and inspector necessary minimum torque has been achieved.
Installation: Fig. 1000 is the "braced pipe" attachment component of a lateral sway
brace assembly. It is intended to be combined with the "bracing pipe" and our structural
attachment component, Fig. 980, 910 or 909 to form a complete bracing assembly.
NFPA 13, FM DS 2-8, and/or OSHPD guidelines should be followed.
To Install: Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through
opening leaving a minimum of 1" extension. Brace pipe can be installed on top or bottom of
pipe to be braced. Tighten hex nuts until leaf spring is flat. It is recommended that the
brace angle be adjusted before hex nuts are fully tightened.
Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved for
use with Allied Dyna Flow sprinkler pipe up to 2" as a restraint device. Maximum horizontal
design load is 655 lbs.
(2.91kN)
Torque requirement is 6-8 ft./lbs.
(8-10Nm).
Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog
approved by the State of California Office of Statewide Health Planning and Development
(OSHPD). For additional load, spacing and placement information relating to OSHPD projects,
please refer to our Seismic Restraint Systems Guidelines.
Application Note: Position Fast Clamp and tighten two hex nuts until leaf spring flattens.
A minimum of 1" pipe extension beyond the Fig. 1000 is recommended.
Finish: Plain. Contact B-Line for alternative finishes and materials.
Order By: Order first by pipe size to be braced, followed by pipe
Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as “Schedule 7”. These ratings may also be applied with EN 10220
and GB/T 8163 steel pipe.
2
Load rating for Schedule 10 above may be applied to GB/T 3092,EN 10255M and H, or JIS G3454, FM Approved Thinwall, or Schedule 40 steel pipes.
Note: See UL load ratings in UL Listed Design Load chart shown under drawing.
Eaton’s B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components,
resulting in a listed seismic bracing assembly. B-Line’s warranty for seismic bracing components will be the warranty provided in
B-Line’s standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from
B-Line’s warranty, Eaton’s B-line Business makes no warranty relating to B-Line’s seismic bracing components that are combined
with products not provided by Eaton’s B-Line Business.
1000-1 X 1
1000-1
1000-1
1000-2 X 1
1000-2
1000-3 X 1
1000-3
1000-4 X 1
1000-5 X 1
1000-6 X 1
71.6 (32.5) 1000-1 X 1
1
/4 X 1 74.8 (33.9) 1000-11/4 X 11/4 79.1 (35.9) 200 (0.89) 280 (1.24) 340 (1.51) 380 (1.69)
1
/2 X 1 77.8 (35.3) 1000-11/2 X 11/4 82.1 (37.2) 200 (0.89) 280 (1.24) 340 (1.51) 380 (1.69)
84.1 (38.1) 1000-2 X 1
1
/2 X 1 90.2 (40.9) 1000-21/2 X 11/4 94.6 (42.9) 200 (0.89) 280 (1.24) 340 (1.51) 380 (1.69)
97.3 (44.1) 1000-3 X 1
1
/2 X 1 104.0 (47.2) 1000-31/2 X 11/4 108.4 (49.2) 230 (1.02) 320 (1.42) 400 (1.78) 450 (2.00)
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Seismic Bracing Products
64
Seismic System Attachments
Fig. 1001 - Sway Brace Attachment
Size Range: Pipe size to be braced: 1"
* Pipe size used for bracing: 1"
(25mm)
Material: Steel
Function: For bracing pipe against sway and seismic disturbance.
The pipe attachment component of a sway brace system:
Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together
with bracing pipe per NFPA 13, forming a complete sway brace assembly.
Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable,
making critical pre-engineering of bracing pipe length unnecessary. Unique design
requires no threading of bracing pipe. Can be used as a component of a four-way
riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in
visual verification of correct installation. See installation note below.
Installation Note: Position Fig. 1001 over the pipe to be braced and tighten
two hex head cone point set screws until heads bottom out. A minimum of
1"
(25mm)
pipe extension is recommended. Brace pipe can be installed on top or
bottom of pipe to be braced.
NFPA 13, FM DS 2-8, and/or OSHPD guidelines should be followed.
Approvals: Underwriters Laboratories Listed in the USA (UL)
and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our
Seismic Restraints Catalog approved by the State of California Office of Statewide
Health Planning and Development (OSHPD). For additional load, spacing and
placement information relating to OSHPD projects, please refer to the TOLCO
Seismic Restraint Systems Guidelines, OPA-0300-10.
Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and
materials.
Order By: Indicate pipe size to be braced followed by pipe size used for bracing,
figure number and finish.
Important Note: Fig. 1001 is precision manufactured to perform its function as
a critical component of a complete bracing assembly. To ensure performance, the
UL Listing requires that Fig. 1001 must be used only with other TOLCO bracing
FM Approved when used with 1 or 11/4 inch NPS Schedule 40 GB/T 3091,EN 10255H, or JIS G3451 steel pipe as the brace member.
2
Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as “Schedule 7”. These ratings may
also be applied with EN 10220 and GB/T 8163 steel pipe.
3
Load rating for Schedule 10 above may be applied to GB/T 3092,EN 10255M and H, or JIS G3454, FM Approved Thinwall,
or Schedule 40 steel pipes.
Eaton’s B-Line Business seismic bracing components are designed
to be compatible only with other B-Line bracing components,
resulting in a listed seismic bracing assembly. B-Line’s warranty for
seismic bracing components will be the warranty provided in
B-Line’s standard terms and conditions of sale made available by
B-Line, except that, in addition to the other exclusions from
B-Line’s warranty, Eaton’s B-line Business makes no warranty
relating to B-Line’s seismic bracing components that are combined
with products not provided by Eaton’s B-Line Business.
1001-1 X 1
1001-1
1001-1
1001-2 X 1
1001-2
1001-3 X 1
1001-4 X 1
1001-6 X 1
1001-8 X 1
100.0 (45.3) 1001-1 X 1
1
/4 X 1 100.0 (45.3) 1001-11/4 X 11/4 114.0 (51,7) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58)
1
/2 X 1 100.0 (45.3) 1001-11/2 X 11/4 115.0 (52.1) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58)
108.0 (49.0) 1001-2 X 1
1
/2 X 1 138.6 (62.8) 1001-21/2 X 11/4 160.4 (72.7) 800 (3.56) 1130 (5.02) 1380 (6.14) 1540 (6.85)
147.2 (66.7) 1001-3 X 1
160.9 (73.0) 1001-4 X 1
190.0 (86.2) 1001-6 X 1
217.4 (98.6) 1001-8 X 1
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Size Range: Pipe size to be braced: 21⁄2"
steel schedules, copper, plastic, FRP, cast iron and ductile iron.
Consult factory when bracing other than steel. The Fig. 2002
accepts brace pipes sizes 1
1
⁄2"
(40mm)
through schedule 40.
Material: Steel
Function: For bracing pipe against sway and seismic disturbance.
The pipe attachment component of a sway brace system:
Fig. 2002 is used in conjunction with a TOLCO 900 Series sway brace
attachments and joined together with bracing pipe. Install per NFPA 13 and/or
our State of California OSHPD Approved Seismic Restrain Manual.
Features: Unique design will not damage thin wall, plastic, copper or ductile
iron pipe. Easy verification of proper installation by tightening bolts until ears
touch.
Installation: Place Fig. 2002 over pipe to be braced. Slide bracing pipe
through attachment and tighten hex nuts until ears touch.
NFPA 13, FM DS 2-8, and/or OSHPD guidelines should be followed.
Approvals: Underwriters Laboratories Listed in the USA (UL) and
Canada (cUL). Included in our Seismic Restraints Catalog approved by the
State of California Office of Statewide Health Planning and Development
(OSHPD). For additional load, spacing and placement information relating
to OSHPD projects, please refer to our Seismic Restraint Systems
Guidelines.
Finish: Plain. Contact B-Line for alternative finishes and materials.
Order By: Figure number, pipe size to be braced, pipe size
used for bracing (1
1
⁄2"
(40mm)
or 2"
Important Note: Fig. 2002 is precision manufactured
to perform its function as a critical component of a complete
bracing assembly. To ensure performance, the UL Listing
requires that the Fig. 2002 must be used only with our other
bracing products.
and 2"
(50mm)
(65mm)
thru 8"
(50mm)
) and finish.
(200mm)
all
steel schedule 100
Component of State of
California OSHPD Approved
Seismic Restraints System
1”
(25.4mm)
Min.
Hardware
Included
Shown with
Fig. 980
Pipe Part Number & Approx. Wt./100 Max. Horizontal
Eaton’s B-Line Business seismic bracing components are designed
to be compatible only with other B-Line bracing components,
resulting in a listed seismic bracing assembly. B-Line’s warranty for
seismic bracing components will be the warranty provided in
B-Line’s standard terms and conditions of sale made available by
B-Line, except that, in addition to the other exclusions from
B-Line’s warranty, Eaton’s B-line Business makes no warranty
relating to B-Line’s seismic bracing components that are combined
with products not provided by Eaton’s B-Line Business.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Seismic Bracing Products
2002-2
/2 X 11/2 224.9 (102.0) 2002-21/2 X 2 283.3 (128.6) 2015 (8.96)
2002-3 X 1
2002-4 X 1
2002-6 X 1
2002-8 X 1
1
/2 241.0 (109.3) 2002-3 X 2 299.4 (135.8) 2015 (8.96)
1
/2 268.4 (121.7) 2002-4 X 2 326.8 (148.2) 2015 (8.96)
1
/2 326.6 (148.1) 2002-6 X 2 385.0 (174.6) 2015 (8.96)
1
/2 381.3 (172.9) 2002-8 X 2 439.7 (199.4) 2015 (8.96)
Size Range: Available in cable diameters of 1/8”, 3/16”, and 1/4”
Cables spooled in 300 foot
Material: Steel
Function: Used for attachment of seismic bracing to structure or hanger.
Features: Meets requirements of IBC 2009 and ASCE 7-05 for seismic bracing.
Finish: Galvanized
Order By: Figure number and size
Note: Only pre-stretched aircraft cable should be used in seismic bracing
installations where cable is used as the bracing component. Use of other types
of cable will, over time, begin to sag and deform, thus rendering the bracing
system to not perform properly.
Part Cable Max. Rec. Approx.
Number Diameter Load* Wt./100 Ft.
in. (mm) lbs. (kN) lbs. (kg)
(91.4m) lengths.
Component of State of
California OSHPD Approved
Seismic Restraints System
BRC CABLE-1/8 1/8” (3.2)
BRC CABLE-3/16 3/16” (4.8)
BRC CABLE-1/4 1/4” (6.3)
* Cable breaking strength
Seismic System
Attachments
Pre-Stretched
Cable
975
(4.33) 2.9 (1.31)
2050
(9.12) 6.5 (2.95)
3150
(14.01) 11.0 (4.99)
7 x 19
Fig. 991 Cable
Sway Brace
Attachment
(Page 63)
Fig. 990 Cable
Sway Brace
Attachment
(Page 50)
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
67
Pre-Stretched
Cable
Seismic Bracing Products
B22, B22A & B24 - Solid Strut Bracing Materials
Size Range: Available in 10 ft (3.05m) and 20 ft. (6.1m) lengths
Material: Steel, Stainless 304 & 316, and Aluminum
Function: Designed to be used as the bracing member for a rigid
bracing system.
Finish: Plain, Dura-Green™, Pre-Galvanized, and Hot-Dipped
Galvanized Steel.
Order By:
Figure
number and finish.
Component of State of
California OSHPD Approved
Seismic Restraints System
Typical Transverse
Brace For Single
Pipe Hanger or
Trapeze Support
Strut Brace Member
Pipe To Be Braced
5°
Typical Longitudinal
Brace For Single
Strut Brace Member
Pipe To Be Braced
Strut Type Maximum Allowable Horizontal
Part No. Length Seismic Load
w/Brace at 45°
5°
B22 9’-6”
B22A 10’-10”
in. (m) lbs. (kN)
(2.89) 2043 (9.08)
(3.30) 3000 (13.3)
B24 8’-0” (2.44) 1078 (4.79)
5°
5°
Typical Longitudinal
Brace For Trapeze
Support
(Typ. Both Sides)
Strut Brace Member
Pipe To Be Braced
Notes:
1.) Maximum allowable lengths and concenrric loads when
L/R = 200
2.) When using strut as a brace material, it must be solid strut.
Slotted or punched are not acceptable.
3.) For more details on B-Line strut, please refer to the
B-Line Strut Systems catalog.
5°
5°
Attachments
Seismic System
B22: 12 Gauge
B24: 14 Gauge
15/8”
(41.3mm)
15/8”
(41.3mm)
15/8”
(41.3mm)
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Seismic Bracing Products
68
B22A: 12 Gauge
31/4”
(82.5mm)
5
1
/8”
(41.3mm)
Loading...