Function: Used as a spacer at a seismic brace location to
keep clevis hanger from collapsing during seismic event.
Approvals: Included in our Seismic Restraints Catalog
approved by the State of California Office of Statewide
Health Planning and Development (OSHPD). For additional
load, spacing and placement information relating to OSHPD
projects, please refer to our Seismic Restraint
Systems Guidelines.
Installation Note: Fig. 1CBS fits easily over the cross bolt
and attaches by pinching tabs down.
Finish: Pre-Galvanized. Contact B-Line for alternative finishes
and materials.
Attachments
Order By:
Pipe Size Approx. Wt./100
Part No. in. (mm) lbs. (kg)
Seismic System
Figure
number and finish.
1CBS-1 1”
1CBS-11/4 11/4” (32) 4.1 (1.8)
1CBS-11/2 11/2” (40) 4.8 (2.2)
1CBS-2 2” (50) 9.4 (4.2)
1CBS-21/2 21/2” (65) 11.4 (5.2)
1CBS-3 3” (75) 13.9 (6.8)
1CBS-31/2 31/2” (90) 16.0 (7.2)
1CBS-4 4” (100) 18.0 (8.1)
1CBS-5 5” (125) 27.3 (12.4)
1CBS-6 6” (150) 32.5 (14.7)
1CBS-8 8” (200) 42.5 (19.2)
1CBS-10 10” (250) 72.7 (32.9)
1CBS-12 12” (300) 86.3 (39.1)
1CBS-14 14” (350) 157.6 (71.5)
1CBS-16 16” (400) 183.7 (83.3)
1CBS-18 18” (450) 224.6 (101.9)
1CBS-20 20” (500) 254.0 (115.2)
(25) 3.2 (1.4)
Component of State of
California OSHPD Approved
Seismic Restraints System
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
51
Seismic Bracing Products
Fig. 120RWA - (Model B) Retrofit Wrap Around “U” Hanger Clamp
Size Range: 1" (25mm) thru 8" (200mm) pipe
Material: Steel
Function: Designed to restrain movement of the pipe within standard
U-hangers as required by NFPA 13. Where retrofit capability is crucial, the
Fig. 120RWA is a labor efficient alternative to the standard B-Line Fig. 120W
wrap around U-hanger.
Features Installs easily by tightening two hex nuts. Features a unique
bracing slot that locks onto a standard U-hanger to become a solid unit that
will stabilize the pipe during seismic activity or sprinkler head activation.
Designed to be used in retrofit or new construction applications. Will clamp
to existing U-Hangers without restriction to leg angle.
Approvals: Underwriters Laboratories listed in the USA (UL) and Canada
(cUL) as a restrainer. Included in our Seismic Restraints Catalog approved by
the State of California Office of Statewide Health Planning and Development
(OSHPD). For additional load, spacing and placement information relating to
OSHPD projects, please refer to our Seismic Restraint Systems Guidelines.
NFPA 13 (2010) 9.3.6.3.
Finish: Plain and Galvanized. Contact B-Line for alternative finishes and
materials.
Order By: Figure number, type numbers and pipe size
Ordering Note: Order by the following type and pipe size:
Type 1 — (1"
Type 2 — (1
(25mm) and 1
1
⁄2" (40mm) and 2" (50mm) pipe size)
1
⁄4" (32mm) pipe size)
Type 3 — (21⁄2" (65mm) and 3" (80mm) pipe size)
Type 4 — (4" (100mm) pipe size)
Type 6 — (5" (125mm) and 6" (150mm) pipe size)
Type 8 — (8"
(200mm) pipe size)
Component of State of
California OSHPD Approved
Seismic Restraints System
Important Note: The bracing slot feature is sized to fit the U-Hanger rod
schedule as required by NFPA 13 as follows:
5
⁄16" (7.9mm) rod for up to 2" (50mm) pipe
3
⁄8" (9.5mm) rod for 21/2" (65mm) - 6" (160mm) pipe
1
⁄2" (12.7mm) rod for 8" (200mm) pipe
For other rod size requirements consult factory.
Type Pipe Size
Part No.
in. (mm)
120RWA-TYPE1-1 1 1" (20)
120RWA-TYPE1-1
120RWA-TYPE2-11/2
1
/4
1 11/4
2 11/2
" (25)
" (40)
120RWA-TYPE2-2 2 2" (50)
120RWA-TYPE3-21/2
3 21/2
" (65)
120RWA-TYPE3-3 3 3" (80)
120RWA-TYPE4-31/2
4 31/2
" (90)
120RWA-TYPE4-4 4 4" (100)
120RWA-TYPE6-5 6 5" (125)
120RWA-TYPE6-6 6 6" (150)
120RWA-TYPE8-8 8 8" (200)
Attachments
Seismic System
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Seismic Bracing Products
52
Seismic System Attachments
Fig. 25 - Surge Restrainer
Size Range: — One size fits 3⁄4"
Material: — Pre-Galvanized Steel
Function: — Designed to be used in conjunction with Fig. 200 band hangers
to restrict the upward movement of piping as it occurs during sprinkler head
activation or earthquake type activity. The surge restrainer is easily and
efficiently installed by snapping into a locking position on the band hanger.
This product is intended to satisfy the requirements as indicated in the National
Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4
Can be used to restrain either steel pipe or CPVC plastic Pipe.
Approvals: — Underwriters Laboratories Listed only when used with band
hanger Fig. 200, in the USA (UL) and Canada (cUL).
Finish: Pre-Galvanized
Order By: Figure number and band hanger, size from
3
⁄4"
(20mm)
thru 2"
(40mm)
Patent #5,344,108
(20mm)
thru 2"
(40mm)
pipe.
.
Seismic System
Attachments
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
53
Seismic Bracing Products
Fig. 98 - Rod Stiffener
Fig. 98B - Rod Stiffener with Break-Off Bolt Head
Size Range: Secures 3⁄8"-16 thru 7⁄8"-9 hanger rod
Material: Steel
Function: Secures channel to hanger rod for vertical seismic bracing.
Approvals: Included in our Seismic Restraints Catalog approved
by the State of California Office of Statewide Health Planning and
Development (OSHPD). For additional load, spacing and placement
information relating to OSHPD projects, please refer to our Seismic Restraint
Systems Guidelines
Finish: Electro Galvanized. Contact B-Line for alternative finishes and materials.
Component of State of
California OSHPD Approved
Seismic Restraints System
Fig. 98
Weight: Approx. Wt./100: Fig. 98 - 11.8 Lbs.
(5.3kg)
Fig. 98B - 12.7 Lbs. (5.7kg)
Order By: Figure number
Fig. SC228 - Hanger Rod Stiffener
Size Range: Secures 3⁄8"-16 thru 5⁄8"-11 hanger rod
Material: Steel
Function: Secures channel to hanger rod for vertical seismic bracing.
Finish: Electro Galvanized. B-Line for alternative finishes
Weight: Approx. Wt./100: 21.0 Lbs.
Order By: Figure part number
Note: Order channel separately
Slight distortion of the channel (strut) may occur upon
installation of rod stiffeners.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Seismic Bracing Products
54
Notes:
1.) Rod stiffeners are required only on hanger and
trapeze assemblies that have seismic bracing
attached at or within 4” (101.6mm) of the rod.
A minimum of two rod stiffeners (Figure 98, 98B,
or SC228) must be installed.
2.) Recommended torque on Figure 98 and SC228
is 8 ft-lbs. (10.8Nm) or finger tight and one full
turn with a wrench.
Figure 98B has the break off bolt head.
Seismic System Attachments
Fig. 4A - Pipe Clamp for Sway Bracing
Size Range: 4"
4"
(100mm)
Material: Steel
Function: For bracing pipe against sway and seismic disturbance.
Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada
(cUL) 4"
approved by the State of California Office of Statewide Health Planning and
Development (OSHPD).
Installation Instructions: Fig. 4A is the "braced pipe" attachment component
of a longitudinal or riser brace assembly. It is intended to be combined with the
"bracing pipe" and our transitional and structural attachment component(s) to
form a complete bracing assembly.
NFPA 13 and/or OSHPD guidelines should be followed.
To Install: Place the Fig. 4A over the pipe to be braced. Attach our transitional
fitting, either Fig. 980, 910 or 909, to the clamp ears. Tighten bolts and nuts;
torque requirement is a minimum of 50 ft./lbs.
Transitional fitting attachment can pivot for adjustment to proper brace angle.
Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and
materials.
Order By: Figure number, pipe size and finish
use B3140.
(100mm)
(100mm)
thru 8"
thru 8"
(200mm)
(200mm)
pipe. For sizes smaller than
. Included in our Seismic Restraints Catalog
(68Nm)
per MSS-SP-58 (2009).
Component of State of
California OSHPD Approved
Seismic Restraints System
A
D
C
HHCS and Hex Nuts Included
Seismic System
Attachments
Fig. 4A - Longitudinal
Brace
Pipe Max. Horizontal Approx.
Part Size A C D Bolt Design Load (UL) Wt./100
No. in. (mm) in. (mm) in. (mm) in. (mm)Sizelbs. (kN) lbs. (kg)
Eaton’s B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components,
resulting in a listed seismic bracing assembly. B-Line’s warranty for seismic bracing components will be the warranty provided in
B-Line’s standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from
B-Line’s warranty, Eaton’s B-line Business makes no warranty relating to B-Line’s seismic bracing components that are combined
with products not provided by Eaton’s B-Line Business.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
55
Seismic Bracing Products
Figure 4B Pipe Clamp for Sway Bracing (Cooper B-Line B386)
Size Range:3⁄4” (20mm) to 8” (200mm) pipe
Material: Steel
Function: For bracing pipe against sway and seismic disturbance
Approvals: Included in the Seismic Restraints Catalog approved by the Stateof California Office of Statewide Health Planning and Development (OSHPD).
Standard Finish: Plain or Electro-Plated, Contact B-Line for alternative
finishes and materials.
Ordering: Specify part number and finish.
Installation Instructions: Fig. 4B is the “braced pipe” attachment
component of a longitudinal or lateral sway brace assembly. It is intended
to be combined with the “bracing pipe” and transitional and structural
attachment component(s) to form a complete bracing assembly.
NFPA 13 and/or OSHPD guidelines should be followed.
To Install: Place the Fig. 4B over the pipe to be braced. Attach other
transitional fitting, Fig. 909, 910, or 980. Tighten bolts and nuts. Transitional
fitting attachment can pivot for adjustment to proper brace angle.
Component of State of
California OSHPD Approved
Seismic Restraints System
C
A
B
D
Shown with two Cooper B-Line
Fig. 980’s and Schedule 40 brace
pipe.
Hanger/Longitudinal Brace
Pipe Size Rod Size B C D Bolt Size Design Load
Fig. 4B
Approx. Wt./100
Part No. in. (mm) A in. (mm) in. (mm) in. (mm) Lbs. (kN) Lbs. (kg)
Eaton’s B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components,
resulting in a listed seismic bracing assembly. B-Line’s warranty for seismic bracing components will be the warranty provided in
B-Line’s standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from
B-Line’s warranty, Eaton’s B-line Business makes no warranty relating to B-Line’s seismic bracing components that are combined
with products not provided by Eaton’s B-Line Business.
Attachments
Seismic System
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Seismic Bracing Products
56
Loading...
+ 12 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.