DualdCoolTM Panel Thermometer
The PM180 DualdCool
TM
is a panel meter that can simultaneously measure temperatures of two probes and/or locations.
An audible alarm sounds for up to one minute when the temperature registers below the minimum or above the maximum settings.
The default Min / Max temperatures are factory-set and stored in the memory. These defaults can be changed and reset by the user.
ACTUAL
SIZE
Choose from three combinations:
PM180-01
• PM180 Panel Thermometer
• 2013 Air Probe
• 2113 Solid Simulator Probe
PM180-02
• PM180 Panel Thermometer
• (2) 2013 Air Probes
PM180-03
• PM180 Panel Thermometer
• (2) 2113 Solid Simulator Probes
PM180-03-032*
• PM180 Panel Thermometer
• (2) 2113 Solid Simulator Probes
*NIST traceable calibration
Specifications
PM180 DualdCool
• Temperature Range: -25° to 180°F (-32° to 82°C)
• Accuracy: ±2°F (±1°C)
• Resolution: 0.1°
• Response Time: 5 second updates
• Display: 2.125” x 2.875” (54 mm x 73 mm)
• 70 decibel alarm (can be disabled)
• Mounting bracket (includes screws & adhesive tape)
• Battery Life: 200 days, (1) AAA (included)
• 1-year warranty
TM
Panel Thermometer
2.125”
(54 mm)
2013
Air Probe
5”
(127 mm)
2113/2113-032
Solid
Simulator Probe
3.5”
(89 mm)
0.125”
(3 mm)
0.85”
(21.5 mm)
Probe Specifications
2013 Air Probe
• Temperature Range: -25° to 180°F (-32° to 82°C)
• Accuracy: ±0.4°F (±0.2°C) 32° to 158°F (0° to 70°C)
• Response Time: 40 sec in 5 m / sec air stream
• Cord Length: 10’ (3 m)
• 1-year warranty
2113 Solid Simulator Probe
• Temperature Range: -25° to 180°F (-32° to 82°C)
• Accuracy: ±0.4°F (±0.2°C) 32° to 158°F (0° to 70°C)
• Response Time: 40 sec in 5 m / sec air stream
• Cord Length: 10’ (3 m)
• Patent pending
• 1-year warranty
Packaging
PM180 Dual Temperature Panel Meter
• Individual Package Weight (PM180-01): 11 oz (312 g)
• Individual Package Weight (PM180-02): 9 oz (255 g)
• Individual Package Weight (PM180-03): 14 oz (399 g)
2.875”
(73 mm)
Mounting
bracket
• Individual Pkg Weight (PM180-03-032): 14 oz (399 g)
• Package Dimensions (L x W x H): 5.125” x 3.75” x 3”
(130 mm x 95 mm x 76 mm)
Accuracy to the Highest Degree
Cooper-Atkins Corporation • 800-835-5011 • 860-347-2256 • www.cooper-atkins.com
TM
DualdCool
Measure the temperature in TWO different locations,
or compare the air and product temperatures in
ONE location...WITHOUT OPENING A DOOR!
The DualdCool
Perishables and other foods in walk-ins and reach-ins must be maintained within strict temperature zones to keep food safe.
Hot-holding cabinets need to preserve the natural moisture of the product in tandem with holding cooked food at safe temperatures.
HERE ARE JUST A FEW APPLICATIONS FOR THIS VERSATILE TOOL:
• Use two air probes to measure the separate ambient temperatures in two different units or two locations in
one unit.
• Combine a solid simulator probe and an air probe. The air probe will capture the changes in air temperature as
doors are opened and closed; the solid simulator probe will simulate the actual temperature of the food.
• Set Min / Max temperature for food storage. Critical limits can be set, and adjusted, by the user.
• Provide an alarm when food reaches unsafe temperatures thus reducing spoilage. A 70 decibel audible alarm,
with flashing display, sounds for up to one minute when critical limits have been exceeded.
• Recall Min / Max temperature feature for each probe. Cycle easily through the captured Min / Max temperatures.
Invaluable for determining if food has entered the temperature danger zone during a specific time period.
TM
can be used inside a variety of storage environments, such as freezers, reach-ins and hot-holding cabinets.
HOT-HOLDING CABINETS
WALK-IN FREEZERS /
REFRIGERATORS
REACH-INS
Min temperature
recalled for Probe 1
Recall separate Min / Max temperatures for each probe!
Max temperature
recalled for Probe 2
Accuracy to the Highest Degree
Cooper-Atkins Corporation • 800-835-5011 • 860-347-2256 • www.cooper-atkins.com
67-1180
V0316