Cooper Power Tools reserves the right to modify, supplement or improve this document or the product without prior notice. This document may not be reproduced in whole or in part in any way, shape or form, or
copied to another natural or machine-readable language or to a data carrier, whether electronic, mechani
cal, optical or otherwise, without the express permission of Cooper Power Tools.
1Safety
1.1Warnings and notes
Warning notes are identified by a signal word and a pictogram:
•The signal word describes the severity and the probability of the impending danger.
•The pictogram describes the type of danger.
WARNING!
Indicates a potentially hazardous situation
which, if not avoided, could result in death or serious injury.
-
CAUTION!
NOTE
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or
property and environmental damage. If this warning is not observed, injuries, property or environmental
damage may occur.
General notes
include application tips and useful information but no hazard warnings.
93b_1_5 en.fm, 30.05.2007P1893E/EN 02/073
1.2Basic requirements for safe working practices
Before using the Battery Charger for the first time, ensure that you have carefully read and understood the
operating instructions. Failure to observe the instructions below may result in electric shock, fire and seri
ous injuries.
CAUTION!
Electrical safety
➔ The Battery Charger is intended exclusively for charging CLECO lithium ion batteries, order no.
935377.
➔ Do not open the Battery Charger.
➔ Do not open the Battery Charger or modify it structurally.
➔ Operate the Battery Charger in dry, enclosed rooms only.
➔ Protect Battery Charger from moisture and rain.
➔ Never operate the Battery Charger under unsuitable ambient conditions (e.g. where combustible
gases, solvents, dust, vapors or moisture is present).
➔ Do not operate the Battery Charger if the housing or power plug are damaged.
➔ Do not charge batteries without supervising them.
➔ Do not use damaged batteries.
Work area
➔ Ensure that there is enough space in the work area.
➔ Keep the work area clean and dry.
-
1.3Designated use
•The CLECO Battery Charger is intended exclusively for charging CLECO lithium ion batteries, order no.
935377.
•Do not use it in areas where there is a risk of explosion.
1.4Items supplied
Check shipment for transit damage and ensure that all items have been supplied:
1 Battery Charger
1 Power cable (EU)
1 Power cable (NA)
1 Operating instructions
1.5Transport
Transport and store the Battery Charger in the original packaging. The packaging can be recycled.
1.6Storage
Storage temperature-20 °C to +70 °C (-4°F to 158°F)
Relative humidity0 to 90 %
4P1893E/EN 02/0793 b_1_5 en.fm, 30.05.2007
2Product description
2.1General description
•Automatic identification of connected battery.
•Automatic identification of a charged battery guarantees optimum charging results.
•Automatic identification of a defective battery.
•Top-off charge phase guarantees the maximum operating time of the battery.
•Charging status display.
•Overcharge protection.
•Wide-range input (100 VAC – 240 VAC) allows the charger to be used worldwide.
•Voltage monitor prevents deep discharging and battery short-circuiting.
2.1.1Display
LEDOperating statusResult
PowerGreen continuous lightPower supply connected
ChargeRed continuous lightBattery being charged
ChargeRed continuous light offBattery is charged
ChargeRed flashing lightDefective or deep-discharged battery
3Initial operation
WARNING!
Risk of explosion if other batteries are used
➔ Use only CLECO lithium ion batteries, order no. 935377.
Never use other battery types.
NOTE
The red "Charge" LED must not be illuminated before the battery is plugged in.
If necessary, when changing batteries, wait a few seconds until the indicator goes off.
➔ Connect the Battery Charger to the power
supply:
The green "Power" LED signals that the
power supply is present.
➔ Plug the battery into the Battery Charger,
until the catch securely engage.
➔ Once the battery is plugged in, the red "Charge" LED is illuminated and indicates that
charging is in process.
When charging is finished, the Battery Charger automatically shuts off the charging process.
The red "Charge" LED goes out.
93b_1_5 en.fm, 30.05.2007P1893E/EN 02/075
4Troubleshooting
ErrorCauseMeasure
The green "Power" LED is not illuminated
when the power supply is connected.
The red "Charge" LED is not illuminated
when the battery is plugged in.
5Maintenance
CAUTION!
Clean the Battery Charger only with the power plug unplugged, and only using a dry cloth.
No power supply voltage.¾ Check and restore the
power supply voltage.
Power cable defective.¾ Replace power cable.
Battery Charger defective.¾ Replace the Battery
Charger.
The battery that is plugged
in has already been
charged (red LED stays off).
The battery contacts are not
connected correctly.
Contacts are dirty.¾ Clean the contacts of
Battery may be faulty.¾ Check battery and
¾ Check battery for proper
function.
¾ Plug the battery in
again.
the Battery Charger and
battery.
replace if necessary.
To ensure proper function, keep the contacts of the charger and batteries free of dirt.
6Service
NOTE
If repair is required, send the complete Battery Charger, to Cooper Power Tools. It may be repaired only by
authorized technicians. Opening the charger will void the warranty.
6P1893E/EN 02/0793 b_1_5 en.fm, 30.05.2007
7Technical data
FeaturesData
Supply voltage100 to 240 V ±10%
Power supply frequency50 to 60 Hz
Rated battery voltage26 VDC
End-of-charge voltage29.4 VDC ±1%
Idle voltageMax. 34 VDC
Charging currentMax. 1200mA ±10%
Degree of protectionIP30
Weight0.7 kg (1 lb 8.7 oz)
Ambient temperature+5°C to +40 °C (+41°C to +104 °C)
Relative humidity0 to 90 %
7.1Dimensions in mm
Height = 90
8Disposal
CAUTION!
Injuries and environmental damage from improper disposal.
Components and auxiliary materials of the charger pose risks to the health and the environment.
➔ Separate the components of the packing and dispose of them by segregating them clearly.
➔ Follow the locally applicable regulations.
➔ Return the Battery Charger and defective/used batteries to your company collection facility or to
Power To ol s .
Cooper
➔ Do not throw the batteries in household refuse, fire or liquids.
Drilling plan
ø4.2
93b_1_5 en.fm, 30.05.2007P1893E/EN 02/077
9CE Declaration of Conformity
8P1893E/EN 02/0793 b_1_5 en.fm, 30.05.2007