Cool Space BLIZZARD50, CS6-50-VD Operation And Maintenance Manual

Operation and Maintenance Manual
BLIZZARD
CS6-50-VD
120V/60HZ
50
1.0 Introduction
1
2.0 Unpacking your COOL- SPACE®
1
3.0 Set-up of COOL-SPACE® unit
1 3.1 Connecting the water supply
1 3.2 Connecting the electrical supply
2
4.0 Operating procedures
3
4.1 Filling the unit with water
3 4.2 Starting the fan
4 4.3 Starting the pump and adjusting the water flow
4
5.0 Maintenance and storage
4
5.1 Removing the cooling media & accessing the inside of the unit
4 5.2 Daily maintenance
5 5.3 Periodic maintenance
5 5.4 Storage
5 6.0 Troubleshooting/Repair
6 6.1 Troubleshooting
6 6.2 Repair procedures
9 6.3 Technical support
9 7.0 Warranty
10
7.1 Warranty form
10
7.2 Warranty parts
10
7.3 Optional accessories and replacement parts
10
Operation & Maintenance Manual
Table of Contents:
Due to continuous product innovations, we reserve the right to change product specification without due notice.
Signal Word Definitions
DANGER indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
WARNING indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.
IMPORTANT indicates a potentially hazardous situation which, if not avoided, MAY result in property damage.
shipping company immediately.
psi. This will cause permanent damage to the unit.
1.0 Introduction
®
COOL-SPACE manufactured in Indiana.
The COOL-SPACE cooler.
2.0 Unpacking your COOL-SPACE
Carefully examine the carton for damage before opening. If the carton is damaged notify the
is a patented and registered Trademark of Hale Industries, Inc. and
®
unit is a compact, self-contained, high-efficiency portable evaporative
®
unit
®
3.0 Set-up of the COOL-SPACE
The COOL-SPACE
®
unit is factory tested and ready to use. The unit should be placed on a
unit
level surface, and the casters locked to prevent inadvertent movement. Follow instructions below to connect water and electrical supply.
3.1 Connecting the water supply
Do not connect the COOL-SPACE® unit to any water source where water pressure exceeds 120
The COOL-SPACE® unit comes equipped with a female garden hose water source connection. Attach the unit to a standard garden hose outlet for a water source. It is not recommended that the unit be attached to any water source with operating pressures above 120 psi. If you have purchased the optional portable water tank, use a standard garden hose (not provided) to connect the tank to the cooler.
1
3.2 Connecting the electrical supply
volt, and 60 Hz circuit.
Do not exceed the amperage ratings of the extension cord. Undersized extension cords result in
THE WARRANTY.
CS Model Number
Volts ± 10%
Frequency (Hz)
Running Amps
CS6-50-VD
120
60
8.2
Length In
Feet
Cord Size
16 Ga
14 Ga
12 Ga
10 Ga
0-50
13 A
18 A
25 A
30 A
50-100
10 A
13 A
18 A
25 A
The COOL-SPACE® unit should be plugged into a fused or circuit breaker protected 20 amp, 120
All models utilize standard 120-volt power supply. The unit should be plugged into a fused or circuit breaker protected 20 amp, 120 volt, 60 Hz circuit.
Table 1 shows the amperage requirements for the specific models. If an extension cord is required, refer to Table 2 for the proper 3-conductor heavy-duty cord required.
excessive drops in voltage, which cause the electric motors to generate excessive heat. This condition results in inefficient motor operation and premature motor failure, WHICH WILL VOID
Table 1. Electrical Requirements
Table 2. Cord size requirement based on length and max amp draw
A: Amps at 120 volt (de-rate for lower voltage)
2