1.FunctionDescription
Thispowersupplyisdesignedforpersonalcomputer.TherearesixDCoutputs:
+5V,+12V1,+12V2,-12V,+3.3V+5V,anditprovidespowertoall
computersystemsandperipheralswithmaximumprotection.
&
SB
Herearesomeofthekeyfeatures:
Itisrathersimpletoinstallthispowersupplytoyourpreciouscomputer
tower.Followthestepsbelowtofinishthesetup.
Step1:Openthecomputertowercover;putthepowersupplyintothe
correspondinglocationofthetower,andthenuserightscrewstofixthe
powersupplytotower.
Step2:PlugfirmlytheMainPowerConnector,ATX12V4PConnectors,S-ATA
Connector,PeripheralConnectorsandFloppyConnectorstothe
correspondingmaleconnectorsofmain-board,peripheraldevices(i.e.
HDD,CDROMetc.)Andfloppydriversrespectively.Whenyouconnect
theconnectors,pleasepayattentiontotheorientationofthembecauseof
thedifferentholesizes.Findtheproperorientationandpushdownfirmly
andbesurethatthepinsarealigned.
2.HowtoSetup
1
Reflectedchassis
ActivePowerFactorCorrection
Externallyselectable3-bandTMS(ThermalManagement
System:Auto/Low/High)tomeetvastmajorityendusers'demands
24-20Pin/4-8Pinconnectorsavailabletosupportboth20Pinand
24Pinsocketmotherboards
Tube-tidedesigntotidythewires
Allkindsofprotectioncircuits(OVP/OCP/OPP/SCP)
Highefficiency:notlessthan75%atfullload

3.Specifications
3.1InputRequirements
3.2ActivePowerFactorCorrection
Thepowersupplyshalloperateasbelow
230V(200Vmin.-264Vmax.),60Hz
115V(100Vmin.-132Vmax.),50Hz
ThepowersupplyisdesignedwithActivePowerFactorCorrectionfunction.Its
THDislessthan5%,whilethepowerfactorreaches0.95min.
2
3.3DCOutput
Powerdistributionconfiguration:
Model
AP-450X(A/PFC)
CP-400T
AP-600X(A/PFC)
CP-500T
AP-500X(A/PFC)
CP-450T
AP-650X(A/PFC)
CP-650T
+3.3V +5V +12V1 +12V2 -12V +5VSB
30A
30A
30A
30A
15A
18A
16A
19A
28A
50A
45A
55A
14A
18A
17A
19A
1A
1A
1A
1A
2.5A
2.5A
2.5A
2.5A
3.4Protection
Thepowersupplyitselfisdesignedwithshortcircuit,overvoltage,noloadand
overpowerprotectionfunctionsdescribedasbelow:

3.4.1ShortCircuitProtection
3.4.2NoLoadOperation
AshortcircuitonanyDCoutputwillcausethepowertolatch.Thepower
supplywillwithstandacontinuousshortcircuittotheoutputwithoutdamage
oroverseerstotheunit.The+5Vcanbeshortedindefinitelyandwillrecover
automaticallywhentheshortisremoved.
NohazardousconditionsordamagetothesupplywilloccurwithalloftheDC
outputconnectorsdisconnectedfromtheload.
SB
3
3.4.3OverPowerProtection
3.4.4OverCurrentProtection
3.5PhysicalEnvironment
OperationConditions
Whenthetotalloadexceed130%~160%ofthemaximumoutputpower,the
powersupplyshallbelatchedintothestateofshutdown.
Overcurrentappliedto+12V1&+12V2shallcausetheoutputtotripbefore
reachingorexceeding240VA.
Thepowersupplyshallbecapableofcontinuousoperationandmeetallelectrical
specificationwithoutneedforadjustmentwhensubjectedtothefollowingenvironÂmentalconditions:
Nodegradationofthepowersupplyshalloccurduringshippingorstorageatthe
specifiedcondition.
3.63-BandThermalManagementSystem
H
ARecommended
L
A
(High):usebymaximumsystemutilization,coolingdowneffectively.
(Auto):PSUregulatesfanspeedautomatically.()
(Low):usebylowsystemutilization,likestand-bymode,etc.When
temperatureincreasesfast,PSUswitchesautomaticallytoLevel(Auto).
DeratingCondition Humidity
Operation
Storage
-20C~80C
10%~90%RH
5%~90%RH
0~30C@FullLoad
30C~40C@90%RatedLoad
40C~50C@80@RatedLoad

4.2Pleasekeepthepowersupplyfromhumidity.
Ifpowersupplycannotworkproperly,beforesendforrepair,checkthe
followingitems:
5.1Doespowercordindeedplugintopoweroutlet?
5.2Doesinputvoltagesetinpowersupplycorrespondtothemainsourceinyour
environment?
5.3Pleasechecktheoutputconnectorsplugginginproperdirectionandconnecting
firmly.
5.SimpleMaintenance
4
5.4Pleaseturnoffthepowerandturnitonforseveraltimes,andtheintervalmust
beatleast5seconds.
5.5Havingcheckedaboveitems,ifthepowersupplystilldoesnotfunction,please
senditbacktoyourretailerordistributorforrepair.
4.Precaution
Caution:Unauthorizedpersonnelshouldnotdothistoavoidelectricalshock!
4.1Donotopenthetopcoverofthepowersupplycase.
3.7RegulatoryCompliance
Ourpowersupplyhasbeencertifiedtocomplywithmulti-nationalSafetyandEMI.
--UL,CUL,CSA,TUV,CE,FCC

Pin13Pin1
SerialATA
Connector
+3.3VDC
COM
+5VDC
+12VDC
+3.3VDC
+3.3VDC
COM
COM
+5VDC
+5VDC
COM
COM
COM
+12VDC
+12VDC
+12V4P
PowerConnector
Nottoscale
6.MechanicalDiagram
PowerConnector/cableadaptorsDrawing
5
1
100718#BLACK
20
10
11
100716#ORANGE
100716#ORANGE
100718#BLACK
100718#RED
100718#BLACK
100718#RED
100718#BLACK
100720#GRAY
100718#PURPLE
100718#YELLOW
100716#ORANGE
100718#BLUE
100718#BLACK
100720#GREEN
100718#BLACK
100718#BLACK
100718#BLACK
100718#RED
100718#RED
100716#ORANGE
100716#ORANGE
100718#RED
100718#BLACK
100718#RED
100718#BLACK
100720#GRAY
100718#PURPLE
100718#YELLOW
PIN11N/A
PIN12N/A
PIN24N/A
100718#BLACK
100718#BLACK
PIN23N/A
100718#RED
100718#RED
100716#ORANGE
100718#BLUE
100720#GREEN
100718#BLACK
100718#BLACK
13
24
12
1
8
100718#BLACK
1
4
100718#YELLOW
5
100718#BLACK
100718#YELLOW
100718#BLACK
100718#YELLOW
100718#BLACK
100718#YELLOW
100718#BLACK
100718#YELLOW
100718#BLACK
100718#YELLOW
20Pinfemale 24Pinmale
8Pinfemale 4Pinmale