80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current Waveform (ITHD = 10.203%, 50% Load)
0.60 0.94 5.88% 10% 65.33 11.66/0.02 3.37/1 5.09/1 5.09/0.21 55.75
85.33%
1.10 0.98 5.66% 20% 123.70 11.63/0.05 3.36/1.99 5.09/1.98 5.08/0.41 111.39
90.05%
2.67 0.99 10.20% 50% 303.66 11.67/0.12 3.33/4.98 5.08/4.94 5.04/1.03 277.84
91.50%
5.35 1.00 5.28% 100% 612.87 11.74/0.25 3.29/9.96 5.05/9.85 4.98/2.07 551.21
89.94%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
Cooler Master Technology Inc.
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient power
supplies (greater than 80% efficiency in the active mode) in technology applications.
http://www.80plus.org/
-6
-4
-2
0
2
4
6
-200
-150
-100
-50
0
50
100
150
200
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current