80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
10-6 Amps
50-60 Hz
700 Watts
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current Waveform (ITHD = 13.51%, 50% Load)
0.80 0.96 17.25% 10% 88.70 12.24/0.03 3.36/1.21 4.98/1.21 5.17/0.25 70.66 79.66%
1.49 0.97 18.07% 20% 165.50 12.34/0.05 3.36/2.42 4.97/2.41 5.16/0.5 141.51 85.50%
3.54 0.98 13.51% 50% 399.40 11.97/0.13 3.34/6.05 4.95/5.99 5.13/1.25 352.14 88.17%
7.24 0.99 6.65% 100% 827.70 12.57/0.25 3.31/12.09 4.9/11.96 5.07/2.51 699.29 84.49%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
Cooler Master Technology Inc.
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
800
900
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-80.0
-60.0
-40.0
-20.0
0.0
20.0
40.0
60.0
80.0
-200
-100
0
100
200
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current