Coolerator Ar1800xt0 Installation Guide

IMPORTANT: Read and save
the& instructions.
Part No, 1155965 Rev. E
IMPORTANT Installer: Leave Installation Instructions
with the homeowner.
Homeowner: Keep Installation Instructions
for future reference.
electrical inspector’s use.
Air Conditioner
Before you start...
Proper installation is your responsibility. Make sure you have everything necessary for correct installation.
It is the customer’s responsibility to comply with the Installation specifications provided.
Grounded electrical outlet within reach of the power supply cord is required. See
Electrical requirements.
Electrical Shock Hazard It is the customer’s responsibility:
l To contact a qualified
electrical installer.
l To assure that electrical
installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 704atest edition and local codes and ordinances.
Check location where air conditioner will be installed. The location should provide:
l A window large enough, l Adequate wall support for
weight of air conditioner,
l An electrical outlet within
reach of sewice cord,
0 Free movement of air to
rooms to be cooled.
Electrlcal outlet must be avallable wlthln reach ot service cord. Do not use extenslon cord.
Important: Observe all governing codes and ordinances.
1
Personal Injury/Product
Damage Hazard
l Because of the weight
and size of the air conditioner, more than one person is needed to move, lift and safely install it.
l Handle air conditioner
with care. Metal fins on front and rear coils are sharp.
. Do Not use the water that
collects inside the air conditioner for drinking purposes. It is not
sanitary.
l Maintain a firm hold on
the air conditioner to prevent it from falling out the window during installation.
l Do Not locate air
conditioner where cabinet front is exposed to a heat source that raises the surface
temperature above
120°F.
Failure to follow these instructions could result in
\
personal injury or damage
to air conditioner.
Tools and materials needed for installation:
-i ‘-2: . .
c
flat-blade .--a screwdriver
Through-the-wall
installations:
wood preservative
F . /-*
y.&
10, #10x1’
screws
or smaller bit
Parts supplied for installation:
‘zrlndow lock 2.slde-
brockeh mbuntlna
window foci strip gasket
round-head, hex-head.round-head,’ i&ierS
metal metal
.S_CES
-A \
screws
Installation parts are supplied for double-hung windows up to 40 inches wide. Installation up to 54
inches can be made with a special, wide window kit available from your dealer or service center.
top-mountingA or-$-
wood
screws
Specific electrical requirements are
Electrical
listed in the chart. Follow the requirements for the type of plug on
requirements
the power supply cord.
Wiring
.
requirements
E!xtrical Shock Hazard
l Electrical ground is required on
this appliance.
l Improper connection of the
Plug Type P
equipment-grounding conductor line can result in electrical shock.
l Check with a qualified
J-prong grounding DIUO
electrician if you are in doubt as to whether the appliance is properly grounded. Do Not modify the plug on the power supply cord. If it will not fit the outlet, have a proper outlet installed by a qualified
grounding. type wall receptacle
electrician.
l Do Not use an extension cord
with this appliance. Such use may result in a fire, electrical
pvwer SUPPlY
CO!d
shock or other personal injury.
m Do Not have a fuse in the neutral
or grounding circuit. A fuse in the neutral or grounding circuit
115volt- 230/208 volt - 2
103.5~ min.,
126.5~ max. 253~ max. 2
could result in electrical shock.
l Grounding wire must be
connected to grounding screw located in lower left corner of air conditioner when air conditioner is in cabinet.
Failure to follow these instructions :ould result in electrical shock.
A three-wire, single-phase, 60-Hz, AC only, electrical supply is required on a separate circuit. A 20-amp time­delay fuse or circuit breaker is reql .ired. Copper wire (#14-gauge)
7Samp 12-amp rating 1 ,atings or less
- double ,ingle outlet Iutlet is acceptable. a-te circuit.
‘.6 through
2-amp atings - use )nly a single )utlet and eparate :ircuit,
is required. The model and serial label is located
behind the front panel above the coil area.
Exomended grounding
Do Not, under any circumstances, remove the power supply cord grounding prong.
‘C
For your personal safety, this appliance must be grounded. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be
Plug Type B Plug Type C
receptacle
receptacle
small tandem 17 blades
grounding prong
grounding
prong
#30/208 volt -
197.6~ min.,
Ir less - use a 2nd a sepa-
1 97.6~ min.
53~ max.
& rating
C
lr less - use a
si
ngle outlet
C
Ind a sepa-
r(
tie circuit.
Panel A