CookTek MCD1500, MC2500, MCD2500, MC3000, MCD3000 Owner's Manual Installation And Operation

...
0 (0)
OWNER’S MANUAL
INSTALLATION
AND OPERATION
Use and Care of CookTek MagnaWave Cooktop –
Models MC1500, MCD1500, MC1800, MCD1800,
MC2500, MCD2500, MC3000, MCD3000,
MC3500, MCD3500, MC2502F, MCD2502F,
MC2502S, MCD2502S, MC3002S, MCD3002S,
CookTek, Inc.
810 W. Washington • Chicago, IL 60607 U.S.A.
Tel: 1-312-563-9600 • Fax: 1-312-432-6220
102922
PREPARING YOUR COOKTEK MAGNAWAVE COOKTOP FOR USE
Before operating your Cooktop, do the following:
1. Remove all packing material.
2. Place the unit on a dry, level, hard, stable, and non-flammable surface.
3. Keep unit away from other heat sources and allow at least 2 inches clearance for air circulation at sides, front and rear of the unit. If either the air intake or exhaust outlet is blocked, the internal temperature will rise, causing an error code to occur.
Grounding Instructions:
The Cooktop must be properly grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing a safe path for the electric current. The Cooktop has a power cord with a 3-prong grounding plug, which must be used in a compatible and properly grounded outlet. It is the owner’s responsi­bility to replace any 2-prong wall outlet with a properly grounded 3-prong wall receptacle.
For your safety, never cut, remove, or disable the electrical (ground) connection from the plug. Never use an adapter plug or an extension cord with the Cooktop.
WARNING: Electric shock can result from an improperly grounded plug. Please consult a qualified electrician if you have any questions about these grounding instructions.
Before You Begin:
Some units may come equipped with a removable IEC Power Cord. Please make sure that this power cord is firmly attached to your CookTek unit BEFORE plugging the unit into the power receptacle and before attempting operation.
ELECTRICAL INSTALLATION REQUIREMENTS*
Every installation site has different electrical wiring. Because many different local codes exist, it is the Owner and Installer’s responsibility to comply with those codes. CookTek is not responsible for any consequential damages as a result of failure to comply with installation requirements.
• Read all installation instructions carefully before starting installation.
• Remove Cooktop carefully from carton.
• Remove all loose packaging and accessories.
• It is the responsibility of the installer to comply with all federal, state and local
codes.
• Any installation not matching the specifications discussed in this manual auto-
matically voids the product’s warranty.
• CookTek recommends that a dedicated electrical line be used for each Cooktop
installed. Electrical circuits should not be shared with any other electrical equipment.
1
INSTALLATION OF DROP IN COOKTOPS
• When installing the drop-in Cooktop, use the dimensions provided in this manual to trace the cutout dimensions onto the countertop.
• Be sure to allow for a minimum clearance of 2” between all sides of the housing and any surface or obstacle, and 9” between the bottom of the housing and any surface or obstacle.
• Cut out and drill holes as required in countertop.
• Drill holes for control box mounting.
• When installing the drop-in Cooktop , apply a bead of an NSF Standard 51 approved sealant (such as Dow Corning 732 Multi-Purpose Sealant or GE RTV
108) around all four edges of the countertop cutout. Carefully follow sealant manufacturer's instructions to insure proper adhesion.
• Multi-Purpose Sealant or GE RTV 108) around all four edges of the countertop cutout. Carefully follow sealant manufacturer’s instructions to insure proper adhesion.
• Locate Cooktop over countertop cutout. Pass control panel and cord through cutout, then pass the base of the Cooktop through the hole until flange rests on the countertop.
• Mount control panel using screws supplied. Mounting options are illustrated in attached drawing.
• Plug Cooktop into a grounded 120V or 200-240V (depending on the model purchased), single-phase receptacle. Check rating plate on the Cooktop to verify correct voltage. NOTE: For proper operation, a dedicated circuit
should be used for each unit installed. Each circuit should be protected with a 20 amp minimum circuit breaker. For best operation, the counter should have an opening near the unit for fresh air to circulate underneath.
APPROVED FOR COMMERCIAL USE
CookTek’s MagnaWave cooktops have been tested to be in conformance with UL 197 and CSA C22.2 standards and bear the commercially rated approvals. CookTek’s Magna Wave cooktops have been tested to be in conformance with the European Economic Area standards and bear the CE marking signifying European Conformity.
COOKING BY POWER COOK (WATTAGE)*
General Operation:
Plug cooktop into a grounded, single-phase receptacle. Models will run on 100­120V drawing up to 1800W depending on model. Or on 208-240V drawing a max­imum of 3500W depending on the model. Check rating plate on unit to verify correct voltage and wattage. Voltages below 120V or 240V can result in less than rated power and slower heating times.
2
Loading...