Precision Air Inflator
Instruction Sheet
recision Air Inflator Includes:
P
1 Precision Air Inflator
1 Power Cord
1 Foot Pedal
1 Carrying Case
View a demonstration of the
Precision Air on Conwin’s
Tools of the Trade DVD
Getting Started
• To prevent the risk of electrical shock, do not use the Precision Air
nflator outdoors when weather conditions are wet. Never operate
I
unit on a wet floor or work area.
• Prior to plugging the Precision Air Inflator into an electrical outlet,
erify that the electrical rating (listed on the label on the back of
v
the Precision Air Inflator) is suitable for outlet.
• If the Precision Air Inflator malfunctions or is damaged in any way
discontinue use and unplug unit from electrical outlet. Contact an
authorized Conwin Service Center for details on how to receive service.
• Never attempt to repair the Precision Air Inflator yourself. Opening
the Precision Air Inflator case will automatically void manufacturer
warranty. Contact an authorized Conwin Service Center for all
repairs.
1 2
Digital
Timer
Readouts
5” Inch
Extension
Outlet
Foot
Pedal
Accessory Item:
Plug the power cord into the side of the unit
and into an electrical outlet. The digital display
will appear when unit has power. (A power
strip with a surge protector is recommended.)
Plug the foot pedal into the side of the unit.
Setting the Precision Air Inflator
1
Reference the time setting chart to set the Precision
Air for the proper balloon size. Set the appropriate
number of Seconds by pressing the arro
on the left side of the control panel digital display
window. (Note: For 5” and smaller balloons, the
second setting should be set at 00.)
w buttons
2
Set the appropriate number of Tenths of a
Second by pressing the arrow buttons on the
right side of the control panel digital display
window.
Baseplates
Conwin's 14-pound white base plates are
posder-coated with an industrial paint
finish. Uniquely designed base plates
feature a rigging point for attaching
archline, and a convenient carr
that holds 2 base plates and 2 risers. Allows
user to transport up to 4 plates at a time
(using 2 sets) - ideal for on-the-job
decorating. Riser is designed to fit standard
/2" elextric
1
al conduit.
ying handle
Balloon Size/Time Settings
TTING
E
E S
OON S
BALL
5” BALLOON
9” BALLOON
11” BALLOON
14” BALLOON
16” BALLOON
E
Z
I
RO
P
AP
0.7 S
1.8 SECONDS
3.3 SECONDS
6.3 S
9.8 SECONDS
X. TI
EC
EC
M
ON
ONDS
DS

Inflating Balloons with the Precision Air Inflator
1
Place the extension tip over the filling outlet
when inflating 5” balloons or 260Qs. Place the
neck of the balloon all the way down on the
extension tip until the neck is touching the
base of the tip.
4
2
Remove the extension tip from the filling
outlet when inflating 9” and larger balloons.
Slightly roll the neck of the balloon over the
inflating tip. This will insure the air enters the
center of the balloon and the round shape of
the balloon is maintained during the inflation
process.
Tap the foot pedal to begin the inflation cycle.
When the system automatically shuts-off,
remove the balloons from the outlets without
allowing any of the air to escape.
3
When inflating 260Q balloons hold the balloon over
the filling outlet and pull the end of the balloon
upward to allow the air to enter into the balloon
more easily.
Using and Resetting the Counter
SSeerrvviiccee &&WWaarrrraanntty
For assistance with service & repair
issues, or for war
please visit
((881188))224466..99223333
or call
04052006
ranty infor
CCoonnwwiinnOOnnlliinnee..ccoomm
y
mation,
,
Every time the foot pedal is pressed the
cycle count will be displayed on the
digital display windows.
The time setting for the inflation cycle
will disappear once the foot pedal has
been pressed. To verify or change the
time setting for the inflation cycle, press
any of the arro
panel once.
The balloon time setting will be displayed
on the digital window. Press the Reset
button in the center of the control panel
to set the counter back to zero.
w buttons on the control
Online
Projects
Designs
Galleries
...and more!
Precautions:
1. The Precision Air features an automatic hot air
vent that exhausts hot air out the bottom of the unit
after each inflation cycle. To prevent the inflator
from over-heating, use only one operator and allow
the unit to fully exhaust the hot air between cycles.
or best results, operate the Precision Air in a
2. F
ature controlled environment. When
temper
working outdoors, keep the unit out of direct
sunlight. If possible, avoid operating unit outdoors
in extremely hot weather. If the unit reaches
temperatures that exceed normal working
conditions, the thermal shut-off control will
automatic
cools down to normal working conditions the
system will reset and be ready for use.
Conwin’s
Update Your Portfolio!
A picture is worth a thousand words.
Is your portfolio up to date on the latest?
Conwin’s Portfolio Builder images are
the perfect solution for making winning
presentations to your clients. Thirty-two
photo quality images are available in
the full series.
ally shut the system do
PPoorrttffoolliioo BBuuiillddeerrss
wn. When the unit
Visit www.ConwinOnline.com today!