Conwin Precision Air Inflator User Manual

Precision Air Inflator
recision Air Inflator Includes:
P
1 Precision Air Inflator 1 Power Cord 1 Foot Pedal 1 Carrying Case
View a demonstration of the
Precision Air on Conwin’s
Tools of the Trade DVD
Getting Started
To prevent the risk of electrical shock, do not use the Precision Air
nflator outdoors when weather conditions are wet. Never operate
I unit on a wet floor or work area.
Prior to plugging the Precision Air Inflator into an electrical outlet,
erify that the electrical rating (listed on the label on the back of
v the Precision Air Inflator) is suitable for outlet.
If the Precision Air Inflator malfunctions or is damaged in any way
discontinue use and unplug unit from electrical outlet. Contact an authorized Conwin Service Center for details on how to receive service.
Never attempt to repair the Precision Air Inflator yourself. Opening
the Precision Air Inflator case will automatically void manufacturer warranty. Contact an authorized Conwin Service Center for all repairs.
1 2
Digital
Timer
Readouts
5” Inch
Extension
Outlet
Foot Pedal
Accessory Item:
Plug the power cord into the side of the unit and into an electrical outlet. The digital display will appear when unit has power. (A power strip with a surge protector is recommended.)
Plug the foot pedal into the side of the unit.
Setting the Precision Air Inflator
1
Reference the time setting chart to set the Precision Air for the proper balloon size. Set the appropriate number of Seconds by pressing the arro on the left side of the control panel digital display window. (Note: For 5” and smaller balloons, the second setting should be set at 00.)
w buttons
2
Set the appropriate number of Tenths of a Second by pressing the arrow buttons on the right side of the control panel digital display window.
Baseplates
Conwin's 14-pound white base plates are posder-coated with an industrial paint finish. Uniquely designed base plates feature a rigging point for attaching archline, and a convenient carr that holds 2 base plates and 2 risers. Allows user to transport up to 4 plates at a time (using 2 sets) - ideal for on-the-job decorating. Riser is designed to fit standard
/2" elextric
1
al conduit.
ying handle
Balloon Size/Time Settings
TTING
E
E S
OON S
BALL
5” BALLOON
9” BALLOON
11” BALLOON
14” BALLOON
16” BALLOON
E
Z
I
RO
P
AP
0.7 S
1.8 SECONDS
3.3 SECONDS
6.3 S
9.8 SECONDS
X. TI
EC
EC
M
ON
ONDS
DS
Inflating Balloons with the Precision Air Inflator
1
Place the extension tip over the filling outlet when inflating 5” balloons or 260Qs. Place the neck of the balloon all the way down on the extension tip until the neck is touching the base of the tip.
4
2
Remove the extension tip from the filling outlet when inflating 9” and larger balloons. Slightly roll the neck of the balloon over the inflating tip. This will insure the air enters the center of the balloon and the round shape of the balloon is maintained during the inflation process.
Tap the foot pedal to begin the inflation cycle. When the system automatically shuts-off, remove the balloons from the outlets without allowing any of the air to escape.
3
When inflating 260Q balloons hold the balloon over the filling outlet and pull the end of the balloon upward to allow the air to enter into the balloon more easily.
Using and Resetting the Counter
SSeerrvviiccee &&WWaarrrraanntty
For assistance with service & repair issues, or for war
please visit
((881188))224466..99223333
or call
04052006
ranty infor
CCoonnwwiinnOOnnlliinnee..ccoomm
y
mation,
,
Every time the foot pedal is pressed the cycle count will be displayed on the digital display windows.
The time setting for the inflation cycle will disappear once the foot pedal has been pressed. To verify or change the time setting for the inflation cycle, press any of the arro panel once.
The balloon time setting will be displayed on the digital window. Press the Reset button in the center of the control panel to set the counter back to zero.
w buttons on the control
Online
Projects
Designs
Galleries
...and more!
Precautions:
1. The Precision Air features an automatic hot air vent that exhausts hot air out the bottom of the unit after each inflation cycle. To prevent the inflator from over-heating, use only one operator and allow the unit to fully exhaust the hot air between cycles.
or best results, operate the Precision Air in a
2. F ature controlled environment. When
temper working outdoors, keep the unit out of direct sunlight. If possible, avoid operating unit outdoors in extremely hot weather. If the unit reaches temperatures that exceed normal working conditions, the thermal shut-off control will automatic cools down to normal working conditions the system will reset and be ready for use.
Conwin’s
Update Your Portfolio!
A picture is worth a thousand words. Is your portfolio up to date on the latest? Conwin’s Portfolio Builder images are the perfect solution for making winning presentations to your clients. Thirty-two photo quality images are available in the full series.
ally shut the system do
PPoorrttffoolliioo BBuuiillddeerrss
wn. When the unit
Visit www.ConwinOnline.com today!