Contura Ci61, Ci61A, Ci61AN, Ci61T Installation Instructions Manual

Page 1
Installation
instructions
contura.eu
Ci61
Ci61A
Ci61AN
Ci61T
Page 2
GB
CERTIFICATE
Declaration of performance according to Regulation (EU) 305/2011
No. Ci61-CPR-190624
PRODUCT
Product type Insert lit with solid biofuels Type designation Contura i61 Manufacturing number See rating plate on the insert Intended area of use Heating of rooms in residential buildings Fuel Wood
MANUFACTURER
Name NIBE AB / Contura Address Box 134, Skulptörvägen 10 SE-285 23 Markaryd, Sweden
CHECKS
According to AVCP System 3 European standard EN 13240:2001/AC:2006, EN-13229:2001/A2:2004/AC:2007 Test institute Rein-Ruhr Feuerstätten Prüfstelle, NB 1625, has checked declared performance and issued test report no. RRF-40 19 5302
DECLARED PERFORMANCE
Essential characteristics Performance Harmonised technical
specification
Reaction to fire NPD
Minimum distance to combustible material Rear: 0 mm
Side: 500 mm Follow the given conditions in the installation instructions.
Risk of falling embers Pass EN 13229:2001/AC:2006,
Emissions from combustion CO 0,07%
Surface temperatures Pass
Cleaning options Pass
Mechanical durability Pass
Emissions of hazardous substances Pass
Nominal output 6,0 kW
Efficiency 81%
Flue gas temperature in connector at nominal output
334°C
EN-13229:2001/A2:2004/AC:2007
The undersigned is responsible for the manufacture and conformity with the declared performance.
Niklas Gunnarsson, Markaryd, August 21, 2015
Business area manager NIBE STOVES
Page 3
GB
A warm welcome to Contura.
Welcome to the Contura family. We hope you will get a great
deal of pleasure from your new insert. Congratulations on
your purchase of a Contura insert. You have acquired a
reliable quality product with a timeless design and long
service life. Contura produces environmentally-friendly wood
burning stoves that create heat in the most efficient way
possible.
Please read these instructions carefully and thoroughly
before installation. The Lighting instructions explain how you
CONTENTS
99
can obtain optimal performance from your stove.
Contents
Technical specifications 100
Chimney 101
Combustion air supply 102
Installation distances 103
Placement and adjustment of insert 105
Assembling the surround 107
Assembling the grate and top 115
NB!
You are required to apply to your local authority for permission to install a fireplace/stove
The owner of the house is personally responsible for ensuring compliance with the mandatory safety requirements and must have the installation approved by a qualified inspector. Your local chimney sweep must also be informed of the installation, as this will affect the routines for regular chimney-sweeping services.
WARNING!
The insert becomes very hot
Parts of the inser t become very hot when it is in use and can cause burns if touched. You should also be careful of the heat that transfers through the door glass. Combustible materials must be kept at the stated safe distance to prevent the risk of fire. A smouldering fire emits gases that can suddenly ignite and cause material damage and personal injury.
Page 4
GB
100
FACT S
Technical specifications
Model i61/i61A/i61AN/i61T Log box (optional)
Output 5-9 kW Nominal output 6,0 kW Efficiency 81%
Weight Ci61/ A/AN / T (kg) 195 /275 / 320 28 Powerstone (option): + 55 kg Width (mm) 590 400 Depth (mm) 500 500 Height (mm) 1570 570
Connection sleeve diameter Ø150 mm ext.
General information
This manual contains instructions about how to assemble and install the Contura i61. More information about the insert is available in the separate installation instructions.
We recommend the fireplace be installed by a qualified tradesperson to ensure it functions safely and properly. Our Contura dealers can recommend suitable installers. Dealer information is available at www.contura.eu
An instruction manual on how to obtain optimal performance from your insert is also provided. Please read this carefully and keep for future reference.
Application to local authority
You must apply for permission from your local authority before installing a stove or erecting a chimney. We recommend you contact your local authority for advice and information about obtaining permission.
Structural support
If the fireplace is to stand on a wooden joist, a structural engineer should be consulted to make sure the floor is able to hold its weight. It is usually necessary to reinforce the wooden joist if the gross weight is more than 400 kg.
Hearth plate
A hearth plate must be installed to protect a combustible floor from the risk of falling embers. It must extend at least 300 mm all the way around. The hearth plate can be natural stone, concrete, metal or glass. A glass hearth plate is available as an optional accessory for these models.
Walls behind
If your Contura i61 is to be installed against a combustible wall, the wall must be protected by a firewall or by the integrated protective screen, which is available as an optional accessory in some markets. Contact your chimney sweep for advice on requirements for materials for a firewall. A non-combustible wall may also require protection if it is a load­bearing wall or if there is combustible material behind it.
Page 5
GB
Chimney
The insert is approved for connection to a chimney designed to withstand flue gas temperatures of up to 350°C. The external diameter of the connection sleeve is Ø The insert requires a draft in the chimney of at least –12 Pa. The draft is affected primarily by the length and area of the chimney and also by how well sealed it is. The minimum recommended chimney length is 3.5 m and a suitable cross-section area is 150-200 cm sealed and that there is no leakage of smoke from the soot doors or connections.
2
(Ø140-160 mm). Carefully check that the chimney is
150 mm.
CHIMNEY
Note that sharp bends and horizontal lengths in a flue pipe reduce the draft in the chimney. The maximum horizontal length of flue pipe allowed is 1 m, provided the flue pipe rises vertically for at least 5 m. It must be possible to sweep the full length of the flue, and the soot doors must be easily accessible.
If two fireplaces are connected to the same chimney flue, the stove must be fitted with a self-closing door. See the instructions for the insert.
101
Rear connection
If connecting at the rear, we recommend using a 45° +45° angle with a soot hatch and with the centre 170 mm above the sleeve.
Note that if connecting at the rear, a heat deflector or protective screen must be installed before the chimney is connected.
170
Page 6
GB
102
SUPPLY
Combustion air supply
A supply of air for combustion must be provided. Combustion air can be drawn directly via a duct from outside, or indirectly via a vent in the outer wall of the room where the stove is placed. The amount of combustion air that is used for combustion is approx.
3
25 m
/h.
Some installation options are shown below. The connection sleeve on the stove has an external diameter of Ø100 mm.
In warm spaces, the duct should be insulated to prevent condensation using 30 mm mineral wool covered with a vapour barrier (aluminium tape). The space between the pipe and the wall (or floor) at the exit point must be properly sealed with flue jointing compound.
A 1-metre combustion-air tube insulated to prevent condensation is available as an optional extra.
HK
130
HK
HK
Supply air down
315
Supply air rear
HK
Page 7
!
GB
Installation distances
Important!
The dimension diagrams only show the minimum permitted installation distances for the stove. When connecting to a steel chimney, the requirements for safe distance to the
Combustible roof
INSTALLATION DISTANCES
Ci61 / Ci61A / Ci61AN / Ci61T
chimney must also be observed. A clearance of at least 1 m must be allowed as a safe distance between the front of the stove and combustible building elements or furnishings.
103
(Min 2120)
1570 550
1390
1220
570 410
234
500
590500
If the stove is to be positioned against a combustible rear wall, the wall must be protected by an external firewall or the integrated protective screen (available as an optional accessory in some markets). The material requirements for the firewall are specified in the section "Walls behind" on page 100
Page 8
GB
104
INSERT PLACEMENT
8 mm
8
VANADIUM
No. 7
CHROME
10 mm
No. 7
CHROME
10
13 mm
No. 7
13
CHROME
PH2 / PZ2 / T20 / T25
VANADIUM
8
10
VANADI UM
13
Allen screw 4
Page 9
GB
Placement and adjustment of insert
1
INSERT PLACEMENT
Ci61 / Ci61A / Ci61AN / Ci61T
105
13 mm
2
13
13 mm
No. 7
CHROME
VANADI UM
13
Page 10
GB
106
INSERT PLACEMENT
Ci61 / Ci61A / Ci61AN / Ci61T
3a
x 2 M5 x 9 Tool T 25
3b
Page 11
GB
Assembling the surround
1
ASSEMBLING THE SURROUND
Ci61 / Ci61A / Ci61AN / Ci61T
107
x 4 M5 x 9 Tool T 25
2
x2
90°
Page 12
GB
108
ASSEMBLING THE SURROUND
3
Ci61 / Ci61A / Ci61AN / Ci61T
x 4 M5 x 9 Tool T 25
4
5
!
x 7 M6 x 25 Allen screw 4
Turn to page 112 to continue with assem­bly instructions for a stone or soapstone surround...
Page 13
GB
ASSEMBLING THE SURROUND
6
109
Ci61
90°
x 16 Nut M5 Tool 8 mm
7
90°
x 12 Nut M5 Tool 8 mm
8
x 4 M6 x 10 Allen screw 4
Page 14
GB
110
ASSEMBLING THE SURROUND
9
Ci61
10
x 2 M5 x 9 Tool T 25
Page 15
GB
11
1
2
x 2 M6 x 20 Tool 10 mm
ASSEMBLING THE SURROUND
Ci61
111
x 4 M5 x 9 Tool T 25
2-3 mm
12
!
Turn to page 19 for installation instructions for the grate and top.
Page 16
GB
112
ASSEMBLING THE SURROUND
6
...continued from page 12.
Ci61T
Ci61A / Ci61AN
x 4 M6 x 10 Allen screw 4
x 4 M6 x 10 Allen screw 4
7 8
Page 17
GB
ASSEMBLING THE SURROUND
113
Ci61A / Ci61AN / Ci61T
9
10
x 2 M5 x 9 Tool T 25
Page 18
GB
114
ASSEMBLING THE SURROUND
11
12
13
Page 19
GB
Assembling the grate and top
If connecting at the rear
1
ASSEMBLING THE GRATE AND TOP
x 2 M6 x 10 Allen screw 4
115
2
Page 20
!
GB
116
ASSEMBLING THE GRATE AND TOP
3
4
~ 25 mm
Page 21
GB
For top connection
1A
x 4
x 4
x 8
ASSEMBLING THE GRATE AND TOP
117
1B
x 2 M6 x 10 Allen screw 4
2
Page 22
!
GB
118
ASSEMBLING THE GRATE AND TOP
x 2
3
4
5
~ 25 mm
Page 23
~5 mm
GB
Disc base
1
ASSEMBLING THE GRATE AND TOP
119
2
Final inspection of the installation
When it has been installed, the stove must be inspected by an authorised inspection body before it can be used. You should also read the “Lighting instructions” before lighting the stove for the first time.
Page 24
811416 IAV SE-EX Ci61 Plåt/Sten-1 2019 -11-06
NIBE AB · Box 134 · 285 23 · Markaryd · Sweden contura.eu
Contura reserves the righ t to change dimensions a nd procedures specified in these instructions without prior notice. Access the latest version at contura.eu