Declaration of performance according
to Regulation (EU) 305/2011
No. Ci61-CPR-190624
PRODUCT
Product type Insert lit with solid biofuels
Type designation Contura i61
Manufacturing number See rating plate on the insert
Intended area of use Heating of rooms in residential buildings
Fuel Wood
MANUFACTURER
Name NIBE AB / Contura
Address Box 134, Skulptörvägen 10
SE-285 23 Markaryd, Sweden
CHECKS
According to AVCP System 3
European standard EN 13240:2001/AC:2006, EN-13229:2001/A2:2004/AC:2007
Test institute Rein-Ruhr Feuerstätten Prüfstelle, NB 1625,
has checked declared performance and issued test report no. RRF-40 19 5302
Minimum distance to combustible materialRear: 0 mm
Side: 500 mm
Follow the given conditions in the installation
instructions.
Risk of falling embersPassEN 13229:2001/AC:2006,
Emissions from combustionCO 0,07%
Surface temperaturesPass
Cleaning optionsPass
Mechanical durabilityPass
Emissions of hazardous substancesPass
Nominal output6,0 kW
Efficiency81%
Flue gas temperature in connector at nominal
output
334°C
EN-13229:2001/A2:2004/AC:2007
The undersigned is responsible for the manufacture and conformity with the declared performance.
Niklas Gunnarsson,
Markaryd, August 21, 2015
Business area manager NIBE STOVES
Page 3
GB
A warm welcome to Contura.
Welcome to the Contura family. We hope you will get a great
deal of pleasure from your new insert. Congratulations on
your purchase of a Contura insert. You have acquired a
reliable quality product with a timeless design and long
service life. Contura produces environmentally-friendly wood
burning stoves that create heat in the most efficient way
possible.
Please read these instructions carefully and thoroughly
before installation. The Lighting instructions explain how you
CONTENTS
99
can obtain optimal performance from your stove.
Contents
Technical specifications 100
Chimney 101
Combustion air supply 102
Installation distances 103
Placement and adjustment of insert 105
Assembling the surround 107
Assembling the grate and top 115
NB!
You are required to apply to your local
authority for permission to install a
fireplace/stove
The owner of the house is personally responsible
for ensuring compliance with the mandatory safety
requirements and must have the installation approved by a
qualified inspector. Your local chimney sweep must also be
informed of the installation, as this will affect the routines
for regular chimney-sweeping services.
WARNING!
The insert becomes very hot
Parts of the inser t become very hot when it is in use and
can cause burns if touched. You should also be careful
of the heat that transfers through the door glass.
Combustible materials must be kept at the stated safe
distance to prevent the risk of fire. A smouldering fire
emits gases that can suddenly ignite and cause material
damage and personal injury.
This manual contains instructions about
how to assemble and install the Contura
i61. More information about the insert
is available in the separate installation
instructions.
We recommend the fireplace be installed
by a qualified tradesperson to ensure
it functions safely and properly. Our
Contura dealers can recommend suitable
installers. Dealer information is available
at www.contura.eu
An instruction manual on how to obtain
optimal performance from your insert is
also provided. Please read this carefully
and keep for future reference.
Application to local authority
You must apply for permission from your
local authority before installing a stove
or erecting a chimney. We recommend
you contact your local authority for
advice and information about obtaining
permission.
Structural support
If the fireplace is to stand on a wooden
joist, a structural engineer should be
consulted to make sure the floor is able
to hold its weight. It is usually necessary
to reinforce the wooden joist if the gross
weight is more than 400 kg.
Hearth plate
A hearth plate must be installed to
protect a combustible floor from the
risk of falling embers. It must extend
at least 300 mm all the way around.
The hearth plate can be natural stone,
concrete, metal or glass. A glass
hearth plate is available as an optional
accessory for these models.
Walls behind
If your Contura i61 is to be installed
against a combustible wall, the wall
must be protected by a firewall or
by the integrated protective screen,
which is available as an optional
accessory in some markets. Contact
your chimney sweep for advice on
requirements for materials for a
firewall. A non-combustible wall may
also require protection if it is a loadbearing wall or if there is combustible
material behind it.
Page 5
GB
Chimney
The insert is approved for connection to a chimney designed to
withstand flue gas temperatures of up to 350°C. The external
diameter of the connection sleeve is Ø
The insert requires a draft in the chimney of at least –12 Pa. The
draft is affected primarily by the length and area of the chimney
and also by how well sealed it is. The minimum recommended
chimney length is 3.5 m and a suitable cross-section area is
150-200 cm
sealed and that there is no leakage of smoke from the soot doors
or connections.
2
(Ø140-160 mm). Carefully check that the chimney is
150 mm.
CHIMNEY
Note that sharp bends and horizontal lengths in a flue pipe reduce
the draft in the chimney. The maximum horizontal length of flue
pipe allowed is 1 m, provided the flue pipe rises vertically for at
least 5 m. It must be possible to sweep the full length of the flue,
and the soot doors must be easily accessible.
If two fireplaces are connected to the same chimney flue, the
stove must be fitted with a self-closing door. See the instructions
for the insert.
101
Rear connection
If connecting at the rear, we recommend using a 45° +45° angle
with a soot hatch and with the centre 170 mm above the sleeve.
Note that if connecting at the rear, a heat deflector or
protective screen must be installed before the chimney is
connected.
170
Page 6
GB
102
SUPPLY
Combustion air supply
A supply of air for combustion must be provided. Combustion air
can be drawn directly via a duct from outside, or indirectly via a
vent in the outer wall of the room where the stove is placed. The
amount of combustion air that is used for combustion is approx.
3
25 m
/h.
Some installation options are shown below. The connection
sleeve on the stove has an external diameter of Ø100 mm.
In warm spaces, the duct should be insulated to prevent
condensation using 30 mm mineral wool covered with a vapour
barrier (aluminium tape). The space between the pipe and the
wall (or floor) at the exit point must be properly sealed with flue
jointing compound.
A 1-metre combustion-air tube insulated to prevent
condensation is available as an optional extra.
HK
130
HK
HK
Supply air down
315
Supply air rear
HK
Page 7
!
GB
Installation distances
Important!
The dimension diagrams only show the minimum permitted
installation distances for the stove. When connecting to a
steel chimney, the requirements for safe distance to the
Combustible roof
INSTALLATION DISTANCES
Ci61 / Ci61A / Ci61AN / Ci61T
chimney must also be observed. A clearance of at least 1 m
must be allowed as a safe distance between the front of the
stove and combustible building elements or furnishings.
103
(Min 2120)
1570550
1390
1220
570410
234
500
590500
If the stove is to be positioned against a
combustible rear wall, the wall must be
protected by an external firewall or the
integrated protective screen (available as
an optional accessory in some markets).
The material requirements for the
firewall are specified in the section "Walls
behind" on page 100
Page 8
GB
104
INSERT PLACEMENT
8 mm
8
VANADIUM
No. 7
CHROME
10 mm
No. 7
CHROME
10
13 mm
No. 7
13
CHROME
PH2 / PZ2 / T20 / T25
VANADIUM
8
10
VANADI UM
13
Allen screw 4
Page 9
GB
Placement and adjustment of insert
1
INSERT PLACEMENT
Ci61 / Ci61A / Ci61AN / Ci61T
105
13 mm
2
13
13 mm
No. 7
CHROME
VANADI UM
13
Page 10
GB
106
INSERT PLACEMENT
Ci61 / Ci61A / Ci61AN / Ci61T
3a
x 2
M5 x 9
Tool T 25
3b
Page 11
GB
Assembling the surround
1
ASSEMBLING THE SURROUND
Ci61 / Ci61A / Ci61AN / Ci61T
107
x 4
M5 x 9
Tool T 25
2
x2
90°
Page 12
GB
108
ASSEMBLING THE SURROUND
3
Ci61 / Ci61A / Ci61AN / Ci61T
x 4
M5 x 9
Tool T 25
4
5
!
x 7
M6 x 25
Allen screw 4
Turn to page 112 to continue with assembly instructions for a stone or soapstone
surround...
Page 13
GB
ASSEMBLING THE SURROUND
6
109
Ci61
90°
x 16
Nut M5
Tool 8 mm
7
90°
x 12
Nut M5
Tool 8 mm
8
x 4
M6 x 10
Allen screw 4
Page 14
GB
110
ASSEMBLING THE SURROUND
9
Ci61
10
x 2
M5 x 9
Tool T 25
Page 15
GB
11
1
2
x 2
M6 x 20
Tool 10 mm
ASSEMBLING THE SURROUND
Ci61
111
x 4
M5 x 9
Tool T 25
≈2-3 mm
12
!
Turn to page 19 for installation
instructions for the grate and top.
Page 16
GB
112
ASSEMBLING THE SURROUND
6
...continued from page 12.
Ci61T
Ci61A / Ci61AN
x 4
M6 x 10
Allen screw 4
x 4
M6 x 10
Allen screw 4
78
Page 17
GB
ASSEMBLING THE SURROUND
113
Ci61A / Ci61AN / Ci61T
9
10
x 2
M5 x 9
Tool T 25
Page 18
GB
114
ASSEMBLING THE SURROUND
11
12
13
Page 19
GB
Assembling the grate and top
If connecting at the rear
1
ASSEMBLING THE GRATE AND TOP
x 2
M6 x 10
Allen screw
4
115
2
Page 20
!
GB
116
ASSEMBLING THE GRATE AND TOP
3
4
~ 25 mm
Page 21
GB
For top connection
1A
x 4
x 4
x 8
ASSEMBLING THE GRATE AND TOP
117
1B
x 2
M6 x 10
Allen screw
4
2
Page 22
!
GB
118
ASSEMBLING THE GRATE AND TOP
x 2
3
4
5
~ 25 mm
Page 23
~5 mm
GB
Disc base
1
ASSEMBLING THE GRATE AND TOP
119
2
Final inspection of the installation
When it has been installed, the stove must be inspected by an authorised inspection body before
it can be used. You should also read the “Lighting instructions” before lighting the stove for the
first time.
Page 24
811416 IAV SE-EX Ci61 Plåt/Sten-1
2019 -11-06
NIBE AB · Box 134 · 285 23 · Markaryd · Sweden
contura.eu
Contura reserves the righ t to change dimensions a nd
procedures specified in these instructions without
prior notice. Access the latest version at contura.eu
Loading...