C 850W
www.contura.eu
Installation
instruction
Installation instruction 2
Installasjonsanvisning 17
Monteringsvejledning 33
Guide d’installation 49
GB
NO
DK
FR

GB
2
PRODUCT
Product type Stove lit with solid biofuels
Type designation Contura 850W
Manufacturing number See rating plate on the stove
Intended area of use Heating of rooms in residential buildings
Fuel Wood
MANUFACTURER
Name NIBE AB / Contura
Address Box 134, Skulptörvägen 10
SE-285 23 Markaryd, Sweden
CHECKS
According to AVCP System 3
European standard EN 13240:2001 / A2:2004
Test institute Rein-Ruhr Feuerstätten Prüfstelle, NB 1625,
has checked declared performance and issued test report no. RRF-40 11 2656
PERFORMANCE DECLARATION
No. C850W-CPR-130610-SE-1
DECLARED PERFORMANCE
Essential characteristics Performance Harmonised technical
specification
Reaction to fire A1 WT
Minimum distance to combustible material 500 mm to side
Other safety distances according to
the installation instructions
Risk of falling embers Approved
Emissions from combustion CO 0.07%
NOx 98 mg/m
3
OGC 51 mg/m3
PM 20 mg/m
3
Surface temperatures Approved
Cleaning options Approved
Mechanical durability Approved
Emissions of hazardous substances Approved
Nominal output 4 kW
Efficiency 82%
Flue gas temperature in connector at nominal
output
320°C
EN 13240:2001 / A2:2004
The undersigned is responsible for the manufacture and conformity with the declared performance.
Niklas Gunnarsson,
Business area manager NIBE STOVES
Markaryd, 1st July 2013
CERTIFICATE

GB
3
CONTENTS
NOTE!
Report the installation of a stove to
your local authority.
The owner of the house is personally responsible
for ensuring compliance with the mandatory safety
requirements and must have the installation approved by
a qualified inspector. Your local chimney sweep must also
be informed about the installation as this will affect the
routines for regular chimney-sweeping services.
WARNING!
The stove becomes very hot
During operation, certain surfaces of the stove become very
hot and can cause burn injuries if touched. Also, take heed
of the strong heat radiated through the door glass. Placing
flammable material closer than the safe distance indicated
may cause a fire. Smoulder combustion can cause quick gas
ignition with the risk of damage to property and personal
injury.
A warm welcome to Contura.
A warm welcome to the Contura family. We hope you
will get a great deal of pleasure from your new stove.
As a new owner of a Contura stove, you have secured
a product with timeless design and long service life.
Contura also has a combustion process that is both
environmentally friendly and efficient, for the best heat
production.
Read through these installation instructions carefully
before installation. Read how to best light your stove
in the lighting instructions.
List of Contents
Technical details 4
Prior to installation 4
Connection to chimney 5
Installation distances 6
Supply of combustion air 6
Installing C 850W 7
Removal 13

1
2
3
GB
4
Technical details Important to remember!
FACT S
Installation by authorised
technician
This manual contains instructions about
how the stove must be assembled and
installed. To ensure the function and safety
of the stove, we recommend that the
installation is carried out by an authorised
technician. Contact one of our dealers who
can recommend suitable fitters.
Building permission
Before installing a stove or erecting a
chimney, it is necessary for you to make an
application for building permission to your
local authority. Ask your local authority for
advice regarding building regulations and
the application.
Structural support
The wall must be strong enough to bear the
weight of the stove and chimney.
Floor plate
Due to the risk of falling embers, a
flammable floor must be protected by a
hearth plate. It must extend 300 mm in
front of the stove and 100 mm on each side
of the stove, or have a 200 mm extension
on each side of the opening. The hearth
plate can consist of natural stone, concrete,
metal plate or glass. A painted metal
or glass hearth plate is available as an
accessory for these models.
If the stove needs to be put down
to be moved or if the pillar foot is
to be installed, remove any loose
components. This is described at the
end of these installation instructions.
1 Fire bars
2 Grate disc
3 Firebricks
Prior to installation
Effect 3-6 kW
Nominal effect 4 kW
Efficiency up to 82%
Model 850W
Height (mm) 615
Width (mm) 460
Depth (mm) 360
Weight (kg) 75
Type approved in accordance with:
European standard EN-13240
Swedish approval
Norwegian standard NS 3059
German standard DIN Plus

4
2
3
1
GB
5
• The stove meets the requirements for connecting to chimneys
dimensioned for 350°C flue gas temperature.
• The external diameter of the connection sleeve is 150 mm.
• The stove requires a draft in the chimney of at least –12 Pa. The
draft is affected both by the length and area of the chimney, and
by how well sealed it is. Minimum recommended chimney length
is 3.5 m and suitable cross section area is 150-200 cm² (140160 mm in diameter).
• A flue with sharp bends and horizontal routing reduces the
draught in the chimney. The maximum horizontal flue is 1 m, on
the condition that the vertical flue length is at least 5 m.
• It must be possible to sweep the full length of the flue and the
soot doors must be easily accessible.
• Carefully check that the chimney is sealed and that there is no
leakage around soot doors and flue connections.
Rear connection to a masonry chimney
The back panel must be installed before the stove is rear
connected.
Connection to chimney
CHIMNEY
Ø approx. 180 mm
In the bag with these installation instructions
are two wing screws for the cover.

6
114
484
56
Utv. Ø150
Tilluftsstos Ø67
430**
800
1100
193
375
11
200**
Brandmur ***
464
Min 300 615 Min 1000
Brännbart tak
730
500
300
100
400
100
200
193
11
375
Brännbar vägg
Brandmur ***
Firewall***
Firewall***
Combustible wall
Air inlet Ø67
Min 1000Min 300
Ext. Ø150
Combustible roof
Installation distances
INSTALLATION DISTANCE / SUPPLY
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
*** Example of an approved firewall is 120 mm solid brick with the following values: (Thermal conductivity (λ) = 0.6-0.7 W/m *K, Density = 1500-1700 kg/m³, as well as Specific heat capacity (c) =
840 J/kg *K).
Indirect air supply through the external wall
Supply of combustion air
Combustion air can be supplied via a duct from outside, or
indirectly via a vent in the outer wall of the room where the stove is
placed. The amount of combustion air that is used for combustion
is approx. 25 m3/h.

7
ASSEMBLY
Installing of C 850W
Insert the connection pipe into the wall
connector towards the folded tabs.
Position the back plate opposite the connector. Check that the back plate is vertical and
mark the mounting holes that you intend to use. Choose a hole so that it ends up as far
away from any mortar joints as possible. Predrill the hole with an 8 mm masonry drill, the
hole must be at least 80 mm deep. Clean the hole thoroughly and secure the back plate to
the chimney breast with the 6 masonry screws supplied. Screws that do not engage must
be considered ineffective and moved to another hole.

10
10
VANADIUM
No. 7
CHROME
10
10
VANADIUM
No. 7
CHROME
4
65
3
GB
8
ASSEMBLY
Ensure that the pipe protrudes 50 mm from the back plate and
seal using the sealing yarn between the wall connector and the
connection pipe. If further sealing material is required, heatresistant sealant may be used.

11
10
GB
10
ASSEMBLY
Secure the brackets using 2
screws at the lower edge.

12
13
14
GB
11
ASSEMBLY
Place the rating plate with production number
and installation distance on the protective
plate with the plate turned downwards.

16
15
GB
12
It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is
used. Also read the "Lighting instructions" before lighting for the first time.
Final inspection of the installation
ASSEMBLY

3
1 2
GB
13
Removal
Handle the firebricks with care. Lift the smoke baffle with one hand whilst removing
the sides. The side posts need not be removed when sweeping. Reinstall in reverse
order.
How to remove the firebricks
REMOVAL

811222 IAV SE-EX C850W-2
2014-01-08
NIBE AB · Box 134 · SE-285 23 Markaryd · Sweden
www.contura.se
Contura reserves the right to change dimensions and
procedures described in these instructions at any time
without special notice. The current edition can be downloaded
from www.contura.eu