CERTIFICATE
PRODUCT
Product type Stove lit with solid biofuels Type designation Contura 520T Manufacturing number See rating plate on the stove Intended area of use Heating of rooms in residential buildings Fuel Wood
MANUFACTURER
Name NIBE AB / Contura Address Box 134, Skulptörvägen 10 SE-285 23 Markaryd, Sweden
CHECKS
According to AVCP System 3 European standard EN 13240:2001 / A2:2004 Test institute Rein-Ruhr Feuerstätten Prüfstelle, NB 1625, has checked declared performance and issued test report no. RRF-40 09 2088
PERFORMANCE DECLARATION
No. C520T-CPR-130601-SE-1
DECLARED PERFORMANCE
Essential characteristics Performance Harmonised technical
specification
Reaction to fire A1 WT
Minimum distance to combustible material 100 mm to rear
470 mm to side Other safety distances according to the installation instructions
Risk of falling embers Approved
Emissions from combustion CO 0.06%
NOx 112 mg/m
3
OGC 58 mg/m3 PM 26 mg/m
3
Surface temperatures Approved
Cleaning options Approved
Mechanical durability Approved
Emissions of hazardous substances Approved
Nominal output 5 kW
Efficiency 79%
Flue gas temperature in connector at nominal output
310°C
EN 13240:2001 / A2:2004
The undersigned is responsible for the manufacture and conformity with the declared performance.
Niklas Gunnarsson,
Business area manager NIBE STOVES
Markaryd, 1st July 2013
Page 3
67
List of Contents
Technical details 68 Removing the loose parts 68 Connection to chimney 70 Supply of combustion air 71 Installation distances 72 Assembly 73 Installing base 76 Installing drawer 77
A warm welcome to Contura
A warm welcome to the Contura family. We hope you will get a great deal of pleasure from your new stove. As a new owner of a Contura stove, you have secured a product with timeless design and long service life. Contura also has a combustion process that is both environmentally friendly and efficient, for the best heat production. Read through these installation instructions carefully before installation. Read how to best light your stove in the lighting instructions.
The stove becomes very hot
During operation, certain surfaces of the stove become
very hot and can cause burn injury if touched. Also, take heed of the strong heat radiated through the door glass. Placing flammable material closer than the safe distance indicated may cause a fire. Smoulder combustion can cause quick gas ignition with the risk of damage to property and personal injury.
NOTE:
WARNING!
Report the installation of a stove to your local authority.
The owner of the house is personally responsible
for ensuring compliance with the mandatory safety requirements and must have the installation approved by a qualified inspector. Your local chimney sweep must also be informed about the installation as this will affect the routines for regular chimney-sweeping services.
CONTENTS
Page 4
68
FACT S
Effect 3-7kW Nominal effect 5 kW Efficiency up to 79%
Model 520T
Height (mm) 1032 Width (mm) 564 Depth (mm) 470 Weight (kg) 210
Type approved in accordance with:
European standard EN-13240 class 1 Swedish environmental and quality marking, P-marking cert. no. 220309 Norwegian standard NS 3059, SINTEF 043-140 German standard DIN, 18.891, RO-91 03 529 Danish standard DS/EN 13240 Plus, id no. 598
Removing the loose parts
If the insert needs to be put down to be moved, loose components should be removed. When the stove is installed reinstall the components in reverse order.
1 Fire bars 2 Grate disc 3 Heat deflector 4 Hearth cladding (Vermiculite).
1
2
3
4
Important to remember!Technical details
Structural support
Check that the wood joists are strong enough to bear the weight of the stove and chimney. The stove and chimney can usually be placed on a normal wooden joist in a single occupancy house, if the total weight does not exceed 400 kg.
Floor plate
Due to the risk of falling embers, a combustible floor must be protected by a hearth plate which covers at least 300 mm to the front and 100 mm along each side. The hearth plate can consist of natural stone, concrete, metal or glass. A painted metal or glass hearth plate is available as an accessory for these models.
Installation by authorised technician
This manual contains instructions about how the stoves must be assembled and installed. To ensure the function and safety of the stove, we recommend that the installation is carried out by an authorised technician. Contact one of our dealers who can recommend suitable fitters.
Building permission
These main insructions may give guidance which would contravene national building regulations. Please refer to supplementary instructions or ask your local authority for advice regarding building regulations. Before installing a stove or erecting a chimney it is necessary for you to make a building application permission to your local authority.
Page 5
69
REMOVAL
How to remove the hearth surround (Vermiculite)
How to remove the heat deflector
Handle the vermiculite with care. Lift the smoke baffle with one hand whilst removing the sides pieces. Reinstall in reverse order
4
4
2
1
Page 6
Ø
ca 180 mm
!
70
CHIMNEY
Connection to chimney
Rear connection to a masonry chimney
Top connection to the chimney
Make sure that the connector gasket does not work loose when the connection pipe is placed on the connector. If further sealing material is required, heat­resistant sealant may be used.
The soapstone is installed after making the rearward connection.
The hot air grille must be installed before chimney top connection.
• The stove meets the requirements for connecting to chimneys
dimensioned for 350°C flue gas temperature.
• The external diameter of the connection sleeve is 150 mm.
• The stove requires a draft in the chimney of at least –12 Pa. The
draft is affected both by the length and area of the chimney, and by how well sealed it is. The minimum recommended chimney length is 3.5 m and suitable cross sectional area is 150-200 cm² (140-160 mm in diameter).
• A flue with sharp bends and horizontal routing reduces the draught in the chimney. The maximum horizontal flue is 1 m, on the
condition that the vertical flue length is at least 5 m.
• It must be possible to sweep the full length of the flue and the
soot doors must be easily accessible.
• Carefully check that the chimney is sealed and that there is no
leakage around soot doors and flue connections.
2 31
5 64
In the bag with these installation instructions are two wing screws for the cover.
Page 7
!
LEK
LEK
40 mm
LEK
40 mm
LEK
30 mm
40 mm
71
SUPPLY AIR/ACCESSORY
Supply of combustion air
When a stove is installed in a room, the demand for air supply to the room increases. Air can be provided indirectly via a vent in the outer wall or via a duct from the outside that is connected to the connector on the underneath of the stove. The amount of air needed for combustion is approx. 25m3/h.
The connector has an external diameter of 67 mm. When duct routing further than 1 m the pipe diameter must be increased to 100 mm and a correspondingly larger wall vent must be selected.
In hot areas the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor (plastic). It is important that the lead-in between the pipe and the wall (or floor) is sealed using jointing compound.
A 1 m length of condensation-insulated ducting for combustion air is available as an accessory.
Through the external wall.
Indirect air supply through the external wall.
Through floor and foundation slab.
Through floor and wall-and-cavity foundation.
In the back and floor plates there are knockouts that must be removed to insert pipes or for air supply if the stove is equipped with a lower hatch and/or fan (accessory).
Installation variants
Leave a 40 mm gap between the condensation insulation and the bottom of the stove.
Page 8
!
C 520T
72
C 520T
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate. Also applies to
separate glass hearth plates (accessory).
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
The minimum distance in front of the stove opening to combustible parts of the building or interior decoration must be at least 1 m.
When top connecting a steel flue, please refer to the particular manufacturer's installation instructions. Observe the safety distance to combustible material that the steel flue requires.
Installation distances
WHEN INSTALLING TURNTABLE (OPTION) the following installation distances do not apply. See the separate installation instructions for turntable.
A = height from floor to chimney
connection upwards
B = height from floor to c/c chimney
connection rear C = height from floor to air inlet D = height from floor to lower edge
of hatch
A separate glass hearth plate (accessory) increases the connection height to the chimney by 10 mm. The spacers supplied with the hearth plate are installed on the stove before connection.
INSTALLATION DISTANCES
564
2000
1032
Air inlet Ø67
Combustible roof
D 300
139
97
B 850
A 942
C 340
30
470
Air inlet Ø67
Ø150
310
65
629
773
Combustible wall
320*
38*
190
50
700
1100
Fire-retardant wall of brick or concrete
280
35
599
731
800
800
Fire-retardant wall of brick or concrete
750
468
240
100
100
200
300
400
60
160
260
360
Combustible wall
Permitted area for combustible parts of the building
Page 9
10
10
VANADIUM
No. 7
CHROME
x 3
!
10
10
VANADIUM
No. 7
CHROME
73
Installing C 520T
ASSEMBLY
3
4
Wait to tighten the back panel’s upper screws until the soapstone sides are in place.
2
1
Installing rating plate
Supplied rating plate positioned on underneath of heat deflector, or with fan option on the inside of the stove.
Page 10
5 mm
3 mm
74
ASSEMBLY
5 6
7
Start with the front stone. It is slightly smaller than the rear. The soapstone sides must protrude 3 mm outside the base plate at the lower edge. Check that the soapstone fits well at the front and back.
Page 11
75
It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used. Also read the ”Lighting instructions”, before lighting for the first time.
Final inspection of the installation
8 9
ASSEMBLY
Page 12
!
76
When installing the base, the knockout in the back panel must always be removed for the supply of convection air.
1
3
2
4
ASSEMBLY
Installing base
Page 13
!
x 3
77
When installing the drawer, the knockout in the back panel must always be removed for the supply of convection air.
1
3
2
ASSEMBLY
Installing drawer
Page 14
Page 15
Page 16
811104 IAV SE-EX C520T - 4 2014-01-28
Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice. The current edition can be downloaded from www.contura.eu
NIBE AB · Box 134 · 285 23 Markaryd · Sweden www.contura.eu