Control Techniques Reconditioned Unidrive M300 AC Drives Catalog

Unidrive M300 AC Drives
S
I
L
3
Safety Integrity Level
Enhance throughput with machine safety, communications, and built-in PLC
Unidrive M300 provides flexible integration with safety and communications. Unidrive M300 is ideal for applications that require cost-effective integration into safety systems. With two Safe Torque Off (STO) inputs, onboard PLC and an SI interface for industry standard fieldbuses, Ethernet or extended I/O options, this feature set ensures Unidrive M300’s flexible integration with any system.
Enhance up-time and system flexibility
Flexible system integration and remote diagnostics through optional industrial
Ethernet and fieldbus communication
Enhanced functionality and onboard PLC programming provides a low-cost system
solution, minimizing the need for additional equipment such as PLCs
High performance open loop motor control
RFC-A (Rotor Flux Control) algorithm for exceptional induction motor control
of demanding applications
Closed loop current control without a position feedback device
Speed control for conveyors, fans, pumps, and mixers, where their function
are controlled remotely with fieldbus or Ethernet communications
Key data
Heavy Duty Ratings: 0.33 hp to 150 hp (0.25 kW to 110 kW)
Unidrive M300 Frame Size 1
Voltage ratings
100 / 120 VAC ± 10%
200 / 240 VAC ± 10%
380 / 480 VAC ± 10%
500 / 575 VAC ± 10%
500 / 690 VAC ± 10%
Control mode
Open loop vector or V/Hz induction motor control
Open loop Rotor Flux Control for induction motors (RFC-A)
ü
ü
ü
ü
ü
ü
ü
Normal Duty Ratings: 0.33 hp to 200 hp (0.25 kW to 132 kW) Supply phases: Frame size 1 and 2: 110 V drives 1Ø,
230 V drives 1Ø or 3Ø; Frame size 7 and larger 3Ø;
460, 575 and 690 V drives 3Ø Control connections: 3x Analog I/O, 5x Digital I/O, 2x STO, 1x Relay Drive rating: IP21 / UL open class as standard Keypad: Fixed LED Option slots: 1 (frame size 2 and above) Parameter cloning via: PC tools, SD card
How to select a drive (Consult online catalog for complete drive information)
1. Electrical Considerations
What is the supply voltage?
Single or 3Ø input power?
What is the motor rating?
Continuous current – FLA (Full Load Amps)
Select the drive based on motor Amps rather than horsepower
2. Load Type (choose one)
Normal Duty: Peak current is 110% of drive rating (fans, pumps, etc.)
Heavy Duty: Peak current is 180% (mixers, conveyors, etc.)
3. Drive Mechanical Mounting
Panel mounting – as standard
Wall mounting – UL conduit kits are available
Through panel mounting – frames 5 and up
0
9
0
1
O
S
I
L
A
A
V
P
O
P
R
UNIDRIVE M300 AC Drives for Industrial Applications
Order Information & Ratings
SOFTW
115 VAC, Single Phase 50/60 Hz Input, 230 VAC 3-Phase Output
Unidrive M300
Order Code*
M300-01100017A 0.33 1.7 0.33 1.7 M300-01100024A 0.5 2.4 0.5 2.4 M300-02100042A 1 4.2 1 4.2 M300-02100056A 1.5 5.6 1.5 5.6
Normal Duty Heavy Duty
hp Amps hp Amps
230 VAC, Single Phase Input, 3-Phase Output, 50/60 Hz Input
Unidrive M300
Order Code*
M300-01200017A 0.33 1.7 0.33 1.7 M300-01200024A 0.5 2.4 0.5 2.4 M300-01200033A 0.75 3.3 0.75 3.3 M300-01200042A 1 4.2 1 4.2 M300-02200024A 0.5 2.4 0.5 2.4 M300-02200033A 0.75 3.3 0.75 3.3 M300-02200042A 1 4.2 1 4.2 M300-02200056A 1.5 5.6 1.5 5.6 M300-02200075A 2 7.5 2 7.5 M300-03200100A 3 10 3 10 M300-04200133A 3 13.3 3 13.3
Normal Duty Heavy Duty
hp Amps hp Amps
230 VAC, Three Phase Input, 3-Phase Output, 50/60 Hz Input
Unidrive M300
Order Code*
M300-02200024A 0.5 2.4 0.5 2.4 M300-02200033A 0.75 3.3 0.75 3.3 M300-02200042A 1 4.2 1 4.2 M300-02200056A 1.5 5.6 1.5 5.6 M300-02200075A 2 7.5 2 7.5 M300-03200100A 3 10 3 10 M300-04200133A 3 M300-04200176A 5 17.6 5 17.6 M300-05200250A 10 30 7.5 25 M300-06200330A 15 50 10 33 M300-06200440A 20 58 15 44 M300-07200610A 25 75 20 61 M300-07200750A 30 94 25 75 M300-07200830A 40 117 30 83 M300-08201160A 50 149 40 116
M300-08201320A 60 180 50 132 M300-09201760x** 75 216 60 176 M300-09202190x** 100 266 75 219
*
Add 10101AB100 to the base order code when ordering standard US (60Hz) default products
**x= A or E (9E frame requires an external AC Line Reactor)
Dimensions & Weights
Frame Size
01 6.3 x 3.0 x5.1 1.7 02 8.1 x 3.1 x 5.9 2.2 03 8.9 x 3.5 x 6.3 3.3 04 10.9 x 4.5 x 6.9 6.9 05 15.4 x 5.6 x 7.9 16.3 06 15.4 x 8.3 x 9.0 30.9 07 21.9 x 10.6 x 11.0 61.7
08 31.7 x 12.2 x 11.4 114.6 09E 39.8 x 12.2 x 11.4 101.4 09A 43.6 x 12.2 x 11.4 146.6
Additional distance should be added to the height dimension (H) when the AI options are fitted.
Dimensions
H x W x D (in)
Normal Duty Heavy Duty
hp Amps hp Amps
13.3 3 13.3
W
Weight
(lbs)
D
Diagnostic Software
Our Drive Diagnostics APP allows users to quickly diagnose faults. In the unlikely event
460 VAC, Three Phase Input, 3-Phase Output, 50/60 Hz Input
M300-02400013A 0.5 1.3 0.5 1.3 M300-02400018A 0.75 1.8 0.75 1.8 M300-02400023A 1 2.3 1 2.3 M300-02400032A 1.5 3.2 1.5 3.2 M300-02400041A 2 4.1 2 4.1 M300-03400056A 3 5.6 3 5.6 M300-03400073A 3 7.3 3 7.3 M300-03400094A 5 9.4 5 9.4 M300-04400135A 7.5 13.5 7.5 13.5 M300-04400170A 10 17 10 17 M300-05400270A 20 30 20 27 M300-05400300A 20 30 20 30 M300-06400350A 25 38 25 35 M300-06400420A 30 48 30 42 M300-06400470A 50 63 30 47 M300-07400660A 60 79 50 66 M300-07400770A 75 94 60 77 M300-07401000A 75 112 75 100 M300-08401340A 125 155 100 134
M300-08401570A 150 184 125 157 M300-09402000x** 150 221 150 180 M300-09402240x** 200 255 150 211
**
x= A or E (9E frame requires an external AC Line Reactor)
Order String - Frame Size Key
Example: M300-XX_ _ _ _ _ _ _
XX = Frame Size (01-09 above)
OPTIONS AT-A-GLANCE
Option Description Order Code
Drive Configuration
& Programming
Operator Interfaces
Input / Output*** Extended I/O SI-I/O
Communications***
H
Application Programming
Software & Diagnostics
Power Accessories
Environmental Protection
& Cable Management
frame sizes 2 and up accept 1 SI option
*** ****Shielded RS485 patch cable, CAT5e, conductive metal RJ45 connectors, XXX=cable length in
5 foot increments (max 330 ft), standard lengths are (005, 010, 015, 025 and 050)
See the Unidrive M: General Purpose AC Drives brochure for our full product offering including 575 V and 690 V solutions.
that you get a drive error, download our complimentary Diagnostics Tool app. Just input the error code on your device and you’ll be given a solution.
INCLUDED
P/N SEL-M300 12/17
Unidrive M300
Order Code*
ARE
Normal Duty Heavy Duty
hp Amps hp Amps
Configuration software UNIDRIVE-M-CONNECT
Drive to PC USB cable (requires a 485 adaptor) Parameter cloning 4 GB
(includes 4 GB SD card)
Parameter cloning
(requires an SD card)
8 GB SD card CTSD8GB
Remote LCD display REMOTE-KEYPAD
Remote LCD display with
real-time clock
Remote display cable UM-LCD-485-XXX****
Modbus RTU AI-485-ADAPTOR
Modbus RTU with 24 V AI-485-24V-ADAPTOR
PROFIBUS DP SI-PROFIBUS
DeviceNet SI-DEVICENET CANopen SI-CANOPEN
PROFINET RT SI-PROFINET-V2
EtherCAT SI-ETHERCAT
EtherNet/IP, Modbus TCP SI-ETHERNET
PLC programming MACHINE-CONTROL-STUDIO Digital oscilloscope CTSCOPE External EMC filter
Line & load reactors
Dynamic braking resistors
UL Type 1 conduit kits
Retrofit for
Commander SK
Fan replacement kits
CT-USB-CABLE
AI-SMART-ADAPTOR
AI-BACKUP-ADAPTOR
REMOTE-KEYPAD-RTC
See the Unidrive M: General Purpose AC Drives brochure
See the Unidrive M: General Purpose AC Drives brochure