HOW TO ORDER Sample Order Number: SX9 1 403 05
Model Stem (Style & Material) Stem (Length) Specific Range
SX9
1 Industrial (Aluminum)
403 31/2" (standard) 05 -40˚ to 300˚ F/C
7" Adjustable 406 6" (standard)
5 Bimetal (304 SS)
604 4" Bimetal
606 6" Bimetal
9 Air-Duct (Aluminum)*
006 6" Air-Duct
012 12" Air-Duct
* Not for use with Thermowell
The Trerice SX9 “Solar Therm”
is ideally suited for replacement
of existing mercury-in-glass
thermometers in environmentally
conscious applications. It features
a rugged cast aluminum case,
easy to read LCD display and an
adjustable-angle stem that is fully
interchangeable with industrial
liquid-in-glass thermometers. Also
available is a bimetal type stem
for applications where a digital
thermometer is preferred over
existing analog bimetals. The
“Solar Therm” requires no
external power and needs only
10 lux of illumination to operate.
The unique Min/Max feature
provides instant recall of minimum
and maximum temperatures over
a given period and is easily reset.
Light Powered
No Batteries Required
7" Case Size
Large LCD ˚F/˚C
Switchable Display
Min/Max Feature
1% or 1˚F Accuracy
Cast Aluminum Case
Adjustable-Angle Stem
SX9 Solar Therm
Light-Powered Digital Thermometer
Model Scale Size
SX9 7" Adjustable Angle
Case
Cast Aluminum,
Blue epoxy finish
Stem
Industrial, Bimetal or Air-Duct
Connection
Industrial: 11/4 -18 UNEF-2A
coupling nut
Bimetal: 304 Stainless steel
1/4" diameter
Air-Duct: Reversible mounting
flange with 3 bolt holes
Sensor
Glass passivated thermistor
Range
-40 to 300˚ F (-40˚ to 150˚ C)
Display
9/16” LCD digits switchable
between F/C. Push button
min/max readings with reset
Accuracy
1% or 1˚ F, whichever is greater
Resolution
1/10˚
Update Interval
10 seconds
Lux Rating
10 Lux (one foot candle)
Ambient Operating Temperature
0 to 140˚ F (-20˚ to 60˚ C)
Ambient Temperature Error
None
Humidity
Maximum: 95 RH,
non condensing
Approximate Shipping Weight
1.5 lbs [0.68 kg]
Specifications
INDUSTRIAL THERMOMETERS
• Optional features available:
Please consult the Options
& Accessories Section for details.
Thermo
well
•
For applications where the
process media may be corrosive
or contained under pressure,
the use of a thermowell is
required to prevent damage to
the thermometer and facilitate
its removal from the process.
(Refer to page 152)
SX91403 shown
12950 W. Eight Mile Road • Oak Park, MI 48237-3288 • TEL:248/399-8000 • FAX: 248/399-7246 • www.TRERICE.com