12
845.778.5566 ● Fax: 845.778.7123 ●
www.nicholsonsteamtrap.com
Thermal actuator is filled at its free length with a
liquid having a lower boiling point than water. On
start-up, valve is normally open. When steam
enters trap, thermal actuator fill vaporizes to a
pressure higher than line pressure. This forces
valve into seat orifice to prevent any further flow.
As condensate collects, it takes heat from thermal
actuator, lowering internal pressure. Line pressure will
then compress thermal actuator to open valve and
discharge condensate. Valve opening automatically
adjusts to load conditions from minimum on very light
loads to full lift at maximum load. Restricted orifice in
N125L (small opening at bottom of valve seat) prevents
trap from discharging continuously on light loads.
N125 SERIES
THERMOSTATIC
STEAM TRAPS
Pressures to 125 PSIG (8.75 barg)
Temperatures to 400°F (204°C)
Superior Performance — Hardened valve and seats are
lapped in matched sets, providing tight shutoff and long
service life.
Improved Energy Savings — Maximum elimination of air
and non-condensibles–trap closes at saturated steam
temperature.
Temperature Sensitive Actuators — One moving part.
Stainless Steel, fail open or fail closed, welded actuator
for maximum corrosion, thermal and hydraulic shock
resistance.
Freeze Proof — Threaded male union horizontal inlet
and vertical outlet–self draining.
In-line Maintenance — Threaded cover for one step
removal, inspection and service without breaking pipe
connections.
Air Vent — Efficient steam service air vent when
equipped with ISO Bellows and installed in air vent
location.
Guaranteed — Guaranteed against defects in materials
or workmanship for 3 years.
M
ODELS*
● N125 – Standard capacity
● N125L – Low capacity
● N125HC – High capacity
● N125ST-FC – Standard capacity w/sterilizer seat
● N125STHC-FC–High capacity w/sterlizer seat
*Add (-FC) for fail closed or (-FO) for fail open to end of model number
APPLICA TIONS
●
Steam Tracing
●Drip Legs
●Automatic Air Vents
●Sterilizers
●Cooking Kettles
●Water Heaters
●Laundry Equipment
●Radiators
●Process Equipment
●Air Handlers
OPTIONS
●
ST - Sterilizer Trim (1/4 & 5/16 orifice sizes)
●SLR - SLR Orifice
●S - Internal Stainless Strainer
●ISO - ISO Filled Actuator
●HC - High Capacity
Canadian Registration # 0E0591.9
See page 9
O
PERATION