Control Products FGA-120-2 User Manual

Page 1
FIBERGLASS AUTOMATIC WATER SOFTENER
45,000 - 750,000 Grains Softening Capacity
301-11 Water Softener
The Parker Automatic Water Softener gives you the best in quality equip­ment to soften water most efficiently at reduced Operating Cost. You can place complete confidence in Parker. For over 50 years, Parker has manu­factured Softeners widely used in laun­dries, hospitals, institutions, schools, hotels, apartments, restaurants, dairies and industrial plants. Each model Softener has been properly engineered and designed to assure the best in quality and to furnish soft water by the most efficient and economical method known. Constant research, develop­ment and proven satisfaction makes the Parker name synonymous with quality.
ADVANTAGES
1. Reliable Control Valve
These softeners include a top mounted solid brass valve with a fully adjust­able 5-cycle control for controlled upflow back wash, downflow brining, slow rinse, rapid rinse, timed brine refill and downflow service. The valve features time proven hydraulically balanced pistons to pilot service flow and regeneration. Models standardly include a built-in 12-day Time Clock. This valve brings great performance and versatility to commercial and industrial water softening applications.
Fiberglass Automatic Water Softener
301-11 Water Softener
2. Safe Low Voltage Controls
All models require a 115 Volt, 1Ph, 60 Hz electrical duplex outlet and include a 115/24 Volt plug-in trans­former and 10 Ft. Extension Cord. The low voltage electrical supply at the softener near the water connec­tions provides greater safety to operating personnel.
3. Softener Tank
The Heavy Duty NSF (National Sanitation Foundation) approved
fiberglass reinforced pressure vessel is totally non-corrosive and assures dependable, rust free service. Softener is suitable for pressures to 100 PSI and temperatures to 110° F.
4. Resin
The FDA approved high capacity lon Exchange Resin has uniform and stable beads to assure long life, high salt efficiency and maximum hardness removal.
PARKER
B O I L E R C O.
NEVER A COMPROMISE FOR QUALITY OR SAFETY
5. Distributor
A bottom stack or hub and lateral distributor system provides maximum service flow and minimal pressure loss.
6. Brine Tank
The high density polyethylene Brine Tank will not crack or rust out and comes complete with a high level shut­off and overflow connection. Dust-tight covers keep out unwanted impurities.
Be sure of getting only the best Water Softener at low initial cost. The Parker is a rugged, heavy duty Industrial soft­ener, built to provide many years of trouble-free service. The purchase of a Parker Softener assures not only the ultimate in quality but the guar­antee of an experienced manufacturer to assure the ultimate in economy of operation and maintenance.
5930 Bandini Boulevard
Los Angeles CA 90040
Fax (323) 722-2848
Phone (323) 727-9800
BROCHURE 301-11 0H1
Page 2
FIBERGLASS AUTOMATIC WATER SOFTENER
BRINE TANK SOFTENER
dia. dia.
tank height
max. height
tank height
45,000 - 750,000 Grains Softening Capacity
301-11 Water Softener
PARKER FIBERGLASS AUTOMATIC WATER SOFTENER
MODEL NO CAPACITY FLOW RATE(G.P.M) PIPE SIZE TANK SIZE (DIA/HEIGHT) INCHES MAX HEIGHT SHIPPING (GRAINS) @15PSIP* @25PSIP** (INCHES) SOFTENER BRINE (INCHES) WEIGHT (LBS)
FGA-45-1 45,000 16 22 1 10/54 18/40 62 140
FGA-90-1 90,000 19 26 1 14/65 24/41 73 240
FGA-120-2 120,000 47 64 2 16/65 24/41 80 450
FGA-180-2 180,000 63 81 2 22/54 24/50 73 575
FGA-240-2 240,000 74 97 2 24/60 30/50 80 825
FGA-300-2 300,000 68 91 2 24/71 30/50 91 975
FGA-450-2 450,000 84 105 2 30/72 39/48 95 1,400
FGA-600-2 600,000 85 100 2 36/72 39/60 95 1,850
FGA-750-2 750,000 90 105 2 36/72 42/60 95 2,100
* Recommended maximum continuous flow rate ** Maximum instantaneous flow rate
NOTE
301-11 Water Softener
1. Electrical: A 115 Volt, 60 Hz, 1 Ph
duplex outlet that is always energized is required. All Models include a 10' Extension Cord and 115/24 Volt Trans­former so that the Softener operates on 24 VAC.
5930 Bandini Boulevard Los Angeles CA 90040
Fax (323) 722-2848
Phone (323) 727-9800
BROCHURE 301-11 0H1
2. Water Requirements: MINIMUM PRESSURE/TEMPERATURE: 25 PSI/34° F MAXIMUM PRESSURE/TEMPERATURE: 100 PSI/110° F The softener tank must not be subject­ed to freezing conditions. If piping has any sediment or iron, install separate filter ahead of softener.
3. The Models FGA-45 through FGA-120 are shipped loaded with Resin. The larger models are shipped with separate Resin and require loading at time of installation.
4. Always locate the softener close to a drain and provide for the installation of a bypass valve.
PARKER
B O I L E R C O.
5. Softener capacities are based on 30,000 Grains per Cu. Ft. of Resin.
6. For dual models, add a “D” in front of the part number.