Control Products ES-300 User Manual

Page 1
112
845.778.5566 Fax: 845.778.7123
www.nicholsonsteamtrap.com
STEAM SEPARATOR
Steam, compressed
air, and gas systems
Steam mains
turbines
Hot air batteries
Heat exchangers
Duplicators
Boilers
Kilns
Radiators
ELIMINATOR SERIES
STEAM & AIR SEPARATOR
Pressures to 990 PSIG (68.2 barg)
Temperatures to 650ºF (344ºC)
Removal of Entrained Contaminants - Extracts
nearly all moisture and solids above 10 microns
Long Service Life - No moving parts mean less
wear and corrosion
High Capacities - Up to 35,000 lbs./hr steam Steel bodies and internals - Withstand
unfavorable conditions and water hammer
Drain Outlet Below Condensate Level - Prevents
steam leakage
Optimal Gravity Discharge - Drain located directly
below the line
Maintenance Free - Regular maintenance is not
required
Steam or Air Service
O
PTIONS
Optional Insulation Jacket
M
AXIMUM OPERATING CONDITIONS
1
2
" - 2" NPT & SW Class 400 - 990 psig (68.2 barg) @ 100ºF (34ºC)
21⁄2" - 6" ANSI 150 Flanged
Class 150 - 285 psig (19.6 barg) @ 100ºF (34ºC)
21⁄2
" - 6" ANSI 300 Flanged
Class 300 - 740 psig (51.0 barg) @ 100ºF (34ºC)
21⁄2
" - 6" ANSI 600 Flanged
Class 400 - 990 psig (68.2 barg) @ 100ºF (34ºC)
MODELS
ES-150 - 150 psig ANSI Flanged
ES-300 - 300 psig ANSI Flanged
ES-600 - 600 psig NPT, Socketweld, ANSI
Flanged
NOTE: This is a fabricated product. Custom
designs are available. Please call factory for details.
When the vapor enters the steam separator, a series of baffles change its flow direction several times. During this process, the baffles in the housing collect impinged water droplets that are carried in the system. Gravity allows the accumulated water droplets and
other foreign particles to fall to the drain and exit the system through a steam trap. The remaining steam in the system is clean and dry, allowing improved and maintained performance.
OPERA TION
ORDERING CODE
MODEL # CONNECTIONS RATING SIZE
(Must be 2 Digits) (Must be 4 Digits)
example: E S T 0 1 5 0 —C
ES - Eliminator T - NPT 0150 - 150# C - 1⁄
2
W - Socketweld 0300 - 300# D - 3⁄
4
F - Flanged 0600 - 600# E - 1
F - 1
1
4
G - 11⁄2
H - 2
J - 2
1
2 K - 3 M - 4 P - 6
Sterilizers
Drip stations before
temperature control or pressure reducing valves
Steam inlets to process
equipment which require dry saturated steam
Before filters and on the
compressed air supply to sensitive instruments
Laundry Processes
APPLICA TION
DATA
Installation Tip: Always install a Steam Trap (i.e.: NFT, FTN,
Max-Flo, Dura-Flo) after the Steam Separator
SEE PAGE 32
Installation Tip: Always install a Y Strainer between the Steam
Separator and Trap.
Loading...