Control Products 4350 User Manual

HOW TO ORDER Sample Order Number: 4350 1 02 07
Model Stem (Material) Stem (Length) Specific Range
4350 Straight 1
Aluminum
* 02 2" (
Aluminum Stem only)
See Standard
Brass Stem only)
Ranges
9 Air-Duct ** 06 6"
12 12"
(
Air-Duct Stem)
*Use of thermowell required (must be ordered separately-refer to page 153).
**Model 4352 only
The Trerice Econo Thermometer provides accuracy and durability at an economical price. This liquid-in-glass thermometer has a durable cast aluminum case and a polycarbonate frame front and window. Rigid straight and rigid 90° angle cases are available.
51/2" Scale Size
± 1 Scale Division Accuracy
Cast Aluminum Case
Rigid Straight or Rigid 90˚Angle Case
Econo-Therm
Models Scale Size
4350 51/2" Rigid Straight 4352 5
1
/2" Rigid 90˚ Angle
Fill Type
Spirit: Blue colored, organic
Case
Cast aluminum, blue epoxy finish
Stem
Aluminum, brass or air-duct style
Connection
Use of thermowell required (must be ordered separately) Air-duct stem has mounting flange with 3 bolt holes
Window
Polycarbonate frame front
Tube
Lens front, magnifying type
Scale
Aluminum, white background with black graduations and markings
Accuracy
±1 scale division
Approximate Shipping Weight
0.5 lbs [0.23 kg]
Specifications
INDUSTRIAL THERMOMETERS
4352 shown
Optional features available: Please consult the Options & Accessories Section for details.
Trerice Econo Thermometers (air-duct stem excluded) have no external mounting hardware, and as such, require the use of a thermowell, which is attached to the stem via a set screw. The thermowell must be ordered separately – please refer to page 153 of the Thermowell Section.
12950 W. Eight Mile Road Oak Park, MI 48237-3288 TEL:248/399-8000 FAX: 248/399-7246 www.TRERICE.com
96
Standard Ranges
Fahrenheit Scale Celsius Scale Dual Scale Fahrenheit Celsius
Range Range Range Figure Minor Figure Minor Code Range Code Range Code Range Intervals Divisions Intervals Divisions
01 –40° to 110°F 17 –40° to 40°C 41 –40° to 110°F &–40° to 40°C 20° 10° 03 30° to 130°F 25 0° to 55°C 43 30° to 130°F & 0° to 55°C 10° 06 30° to 180°F 27 0° to 83°C 46 30° to 180°F & 0° to 83°C 20° 10° 07 30° to 240°F 19 0° to 115°C 47 30° to 240°F & 0° to 115°C 20° 10° 08 30° to 300°F 20 0° to 150°C 48 30° to 300°F & 0° to 150°C 30° 10° 09 50° to 400°F 28 10° to 205°C 49 50° to 400°F & 10° to 205°C 50° 20° 13 200° to 500°F 32 93° to 260°C 53 200° to 500°F & 93° to 260°C 25° 10°
Econo-Therm
INDUSTRIAL THERMOMETERS
U Length Dimension
2" (Aluminum) 1.31 [33.3] 4" (Brass) 3.25 [82.6] 6" (Air-Duct) 6.00 [152.4] 12" (Air-Duct) 12.00 [304.8]
Note: Shown with required thermowell (must be ordered separately. Refer to page 153.)
AIR-DUCT STEM
MOUNTING DIMENSIONS
AIR-DUCT STEM
Ø.25 - 3 HOLES
EQUALLY
SPACED
Ø2.50
[
Ø64]
Ø1.50
[
Ø38]
U
Ø.50
[13]
.88 [22]
HEX
1.42 [36]
U
U
.82
[21]
1.33 [34]
6.69
[170]
1.62 [41]
Ø.53
[14]
Dual scale figure intervals may differ.
All dimensions are nominal. Dimensions in [ ] are in millimeters.
97
12950 W. Eight Mile Road Oak Park, MI 48237-3288 TEL:248/399-8000 FAX: 248/399-7246 www.TRERICE.com