Controlled Entry Distributors SAM1000 Users Manual

SEBURY
SAM-1000
Digital Keypad
The SAM-1000 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming is done through the keypad. Codes and operating parameters are stored within the microprocessor and can not be lost due to power failure.
The SAM-1000 can store 1000 prox cards and user 4 digit codes. Each 4 digit code has 10,000 possible combinations. The unit has one relay with 5 Amp contacts.
CONTENTS Page
Introduction ……………………………………………………………. 2 Product Specifications …………………………………………………. 3
Intramural Interface Circuit…………………………………………….
Mounting & PCB Diagram ……………………………………………. 4 Wiring Diagram ………………………………………………………. 4-5 Engineer Programming Information and Notes …………………….. 5 Engineer Programming Factory Default Setting ………………………………………….. 6 Changing Master & User Codes………………………………….. 7 Setting Functions of Master & User ……………………………. 7 Set Door Relay Strike ……………………………………………… 7 Set Door Open Detection Time …………………………………. 8 Security Arrangement ……………………………………………. 9 Exit Engineer Programming Mode ……………………………… 9 Resetting Non Volatile Memory ………………………………………. 9 Installer Information & Notes …………………………………………… 9 Technical Specifications ….…………………………………………… 10
2
Specifications
1. Programmable Functions
Relay latching or momentary Relay activate independently or together Change Codes 1 master, 1000 users & prox cards Door open detection
2. Programmable Timers
Door relay time 00-99 seconds Door open detection 00-99 seconds Alarm time 00-99 minutes
3. Wiring Connections
Electric lock External bell External Push Switch Magnetic Contacts Alarm
4. Keypad:
12 keys
5. Programming memory:
Non volatile Eeprom memory
IMPORTANT INFORAMTION
There are no user serviceable parts contained within the SAM-100 0 access control keypad.
If holes are to be drilled before mounting onto a wall, check for hidden cables and/or pipes before drilling. Use safety goggles when drilling or hammering in ca ble clips.
Every effort has been made to provide accurate information, however slight variations can occur. We also reserve the right to make changes for product improvement at any time
NOTE
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL THE SAM-1000
Intramural Interface Circuit
1. Alarm output interface (See Figure 1)
2. Electric lock interface (See Figure 2)
3
Figure 1 Figure 2
Mounting
1. Attach the rear plate to a single or double gang electrical box or secure to the wall firmly with at least three flat head screws.
2. When wiring has been completed, attach the front cover to the rear plate.
Figure 3
4
Figure 4
The front cover can be permanently secured by using the short screw supplied
SAM-1000 Printed Circuit Board
Wiring
1. Unplug the cable harness and connect the necessary cables, (See Figure 5).
2. Tape any wires that are unused.
3. Plug the cable harness , (See Figure 5)
4. Attach the front cover, (See Figure 3).
Terminal Wire Connector 1 Function
10 Bell1 White Bell Push Button 9 Bell2 White Bell Push Button 8 12V Red (+) 12Vdc Positive Regulated Power Input 7 GND Black (-) Negative Regulated Power Input 6 COM Orange Door Strike Relay Com 5 NO Blue Door Strike Relay N/O 4 NC Green Door Strike Relay N/C 3 D_IN Brown To Door Contact Then To Door In 2 OPEN Yellow To Door Remo te Control Button Then Negative 1 ALARM Grey Alarm
Warning! Do not plug adaptor our transformer into mains until all wiring has been completed and the front cover secured.
5
Figure 5
Power Up
1. After all wiring is complete and the unit face plate is attached to the back plate, apply 12Vdc power to the unit. Accept LED(the yellow LED) flashing.
Engineer Programming Mode
To enter programming mode
Press: * 9999 # within 5 seconds, Ready(the green LE D) and Accept LED illuminated, Open LED flashing.
Note
Press: # to save changes and exit engineer programming, when all programming has been completed otherwise changes will not be saved.
Changing Master & User Codes
In engineer programming mode:
To change Master code Press: 0 new master code # re-enter new master code #
6
Upon acceptance Open LED illuminates and stops flashing. Press * after changing the master code, otherwise unit will disregard the new code and revert back to the factory default code. Note: the master code must be 4-8 digit number.
Adding User Codes & Cards
To Add User cards & codes
Press: 1 read card user identification # Note: the user identification must be 3 digit number, if adding more than 1 card, read the next card after inputting the 3 digit code for the previous card, when you have finished adding all cards press the # key. 1st card must be 000 up to 999. Then the SAM-1000 control station added a user card it was auto added a user code with 1234.
Delete User Card or Cards
There are 3 options to delete a user card or cards, in engineering mode. a.) Press: 2 0 0 0 0 # to delete all user cards
b.) Press: 2 read card # to delete individual user card c.) Press: 2 user identification number # to delete individual user card
User Operation Mode
There are 3 different options for user operation mode, card only, card and password, valid code. The optioned used is common to all users.
Press: 3 0 0 # valid card only Press: 3 0 1 # valid card and password Press: 3 0 2 # valid card or pass word
Setting Door Relay Strike Time
The door relay output can be operated as either normall y opened or normally closed, a maximum current of 10 ampere can pass through the relay if used as normally opened or 5 ampere if normally closed. The door relay time can be set from 0 seconds to a maximum of 99 seconds. The factory default setting is 6 seconds and can be changed through the keypad.
Press: 4 new time from 00-99 seconds #
Setting Alarm Signal Output Time
Press: 5 new time from 00-99 minutes #
Setting Door Open Detection
7
Press: 6 0 0 # to disable this function (factory setting) Press: 6 0 1 # to enable this function.
In order for this feature to work, door contacts must be connected. There are 2 programming functions that work together in this mode.
a.) If door not closed after opening, keypad buzzer sounds. b.) If door forced open, keypad buzzer sounds and sends alarm signal.
Setting Security Arrangement
There are two levels of keypad security available for the SAM-1000. Press: 7 0 1 # to read 10 invalid cards or valid cards, then enter 4 wrong
passwords in succession, the keypad is locked for 10 minutes. Press: 7 0 2 # to read 10 invalid cards or valid cards, then enter 4 wrong
passwords in succession, the keypad activates and alarm signal. To disable this feature:
Press: 7 0 0 # factory default setting.
Resetting To Factory Default Setting
To revert all settings to the factory default values then the Non Volatile Memory (Eeprom) must be reset.
Reset Non Volatile Memory by switching of the power and placing the jumper connector onto the pins 1 & 2 as per figure 2. After switching power on remove jumper, the SAM-1000 will give a beep and is now reset to factory default values.
Changing User Password Code
The factory default setting for each user password code 1234, this can be modified so that each user has a unique individual 4 digit code.
Press: * read user card user passoword # new password # re-enter
new p assword #
Using Password Code to release the door
Press: user passoword #
Technical Specification
DC Supply Voltage: Low voltage input 12 ±10% Vdc unregulated Current Consumption: 100mA @ quiescent maximum Door Relay: 5Amp 12Vdc
8
Alarm output load: 150mA pull current Tamper Protection: Negative loop, normally closed Codes : 1 Master, 1000 cards and 1000 codes . Keypad: 12 keys, 3 LED status indicators Card Types: EM or EM compatible Induction Distance: 5-8cm Wiring Connections: Electric lock Remote door control Door open detection External door bell External Alarm
Memory: Non volatile eeprom memory Operating Temperature: 0°C to 60°C (32°F to 140°F) Keypad Housing: Metal Dimensions: 128mm x 82mm x 28mm Weight: 500g
Package Listing
Name Model no. Quantity Remark
Digital Keypad SAM-1000 1
User Manual SAM-1000 1
Flat Head Screws
Pastern Stopper
Self Tapping Screws
Φ3mm×6mm Φ6mm×27 mm
Φ3.5mm×27 mm
1 Used for front case and back case 4 Used for fixing
4 Used for fixing
9
FCC WARNING
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
The antenna provided is a unique antenna. By installation of unauthorized antenna to this equipment. Such unauthorized installation could void the user's authority to opearte the equipment.
NOTE: The manufacturer is not responsible for and radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.