Introduction
The SAM-1000 uses the latest microprocessor technology to operate door strikes
and security systems that require a momentary (timed) or latching dry contact
closure.
All programming is done through the keypad. Codes and operating parameters are
stored within the microprocessor and can not be lost due to power failure.
The SAM-1000 can store 1000 prox cards and user 4 digit codes. Each 4 digit code
has 10,000 possible combinations. The unit has one relay with 5 Amp contacts.
CONTENTS Page
Introduction ……………………………………………………………. 2
Product Specifications …………………………………………………. 3
Intramural Interface Circuit…………………………………………….
Mounting & PCB Diagram ……………………………………………. 4
Wiring Diagram ………………………………………………………. 4-5
Engineer Programming Information and Notes …………………….. 5
Engineer Programming
Factory Default Setting ………………………………………….. 6
Changing Master & User Codes………………………………….. 7
Setting Functions of Master & User ……………………………. 7
Set Door Relay Strike ……………………………………………… 7
Set Door Open Detection Time …………………………………. 8
Security Arrangement ……………………………………………. 9
Exit Engineer Programming Mode ……………………………… 9
Resetting Non Volatile Memory ………………………………………. 9
Installer Information & Notes …………………………………………… 9
Technical Specifications ….…………………………………………… 10
2

Specifications
1. Programmable Functions
Relay latching or momentary
Relay activate independently or together
Change Codes 1 master, 1000 users & prox cards
Door open detection
2. Programmable Timers
Door relay time 00-99 seconds
Door open detection 00-99 seconds
Alarm time 00-99 minutes
3. Wiring Connections
Electric lock
External bell
External Push Switch
Magnetic Contacts
Alarm
4. Keypad:
12 keys
5. Programming memory:
Non volatile Eeprom memory
IMPORTANT INFORAMTION
There are no user serviceable parts contained within the SAM-100 0 access control
keypad.
If holes are to be drilled before mounting onto a wall, check for hidden cables and/or
pipes before drilling. Use safety goggles when drilling or hammering in ca ble clips.
Every effort has been made to provide accurate information, however slight variations
can occur. We also reserve the right to make changes for product improvement at
any time
NOTE
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO
INSTALL THE SAM-1000
Intramural Interface Circuit
1. Alarm output interface (See Figure 1)
2. Electric lock interface (See Figure 2)
3