Controlled Entry Distributors REATSHE Users Manual

W2 - Waterproof
Standalone Proximity Reader
1. Packing List
Name Standalone Proximity Reader Infrared remote control Manager card Short Pin User manual Self Tapping Screws
Specification
W2
One for add, one for delete
Used for factory default setting
W2
3.5*27mm
Quantity
1 1 2 1 1
4/2
2.Description
The W2 is fully waterproof Proximity stand alone access Reader, which uses advanced microprocessor, equipped with large capacity Flash memory, supports up to 10 000 cards. It is so easy to add or delete card users by using the master card, besides, with Infrared remote control programmer, the user can set the features by themselves, including Alarm, Self-protection, interlock and Anti­submarine back Function. In additional, with infrared remote control programmer, you can add or delete cards directly by inputting card number
The W2 not only has the features of low power consumption, automatic selection of lock ,anti vandal alarm and exit button, but also has the protective functions against input over voltage and outputs short-circuit. These features make the W2 safe , reliable and easy in operation. It is an idea choice for door access.
3.Features
Standalone Card Reader Use capacity: 10,000 Card interface: 125KHZ EM card Remote control for programming With Manager cards for fast add
and delete users
Wiegand26 input/output
Can be used as salve reader 2 pcsW2 can be interconnected/ interlocked Can be used as controller by connection
slave reader
Anti-submarine back Function Alarm signal output, Door open detection Full of 10000 users, recognizing speed <15ms.
.1. .2. .3.
4. Specifications
Supply Voltage Sleeping Current Card type Card Reading Distance Wiegand interface Temperature
DC12V 10% <15mA 125KHZ EM card 5 10cm Wiegand 26
-20 60
5. Installation
Drill holes on the wall or prepare the cassette. Wire through the hole, and blanket the unused
cable in case of short circuit.
Fix the back cover firmly on the cassette or the wall. Attach the reader to the back cover.
6. Wiring
Color
No
Green
1 2
White Grey
3
Yellow
4 5
Brown Red
6
Black
7
Blue
8
Purple
9
Orange
10
Function D0 D1 ALARM+ OPEN D_IN 12V GND
VSS
L-
L+/Alarm+
Description Wiegand output, input signal wire D0 Wiegand output, input signal wire D1 connecting to the negative pole of the alarm equipment To connect to one part of Exit Button Door Contact input (+) 12Vdc Positive Regulated Power Input (-) Negative Regulated Power Input the negative pole of the controller, connect to the other
part of Exit button and door contact
Connect to the negative pole of the Lock Connect to the positive pole of the lock and alarm equipment
Humidity Lock output load Alarm output load Manager card Dimensions
A
95.5mm
B
40mm
20% 98% Max20A Max20A Two 103*48*23mm
61mm
Connection Diagram
W2
J1
Green
D0
White
D1
Grey
ALARM-
OPEN
Yellow Brown
ALARM+
ALARM-
OPEN
D_IN
+12V
GND
VSS
L+
ALARM+
D_IN +12V
GND VSS
L+
D0 D1
L-
Red Black Blue Purple
L-
Orange
J1
Green White Grey
Yellow
door detecting switch
Brown Red Black Blue Purple Orange
C
Shielded cables
D
Common Power Supply
door detecting switch
Exit button
Alarm
Exit button
Alarm
DC12V/3A
-
+
+
­Lock
+
DC12V/3A
COM
-
NCNOPUSH
+
Fail-safe lock
Special Power Supply
-
Fail-securelock
7. Interface Circuits
Lock Interface Principle:
By programme setting, I/O switch between low level and high level.
4-low level 5-high level
I/O
R7
Note: The above diagrams show the output interface circuits. Do not power on until all wiring has been completed
+12V
R19
Alarm Interface Principle: when alarm, the I/O outputs high level.
L+
D6
I/O
L-
Q2
R8
Figure 1
ALARM-
Q6
R20
8.To Reset to Factory Default and Manager Card setting
Power off, use the supplied Contact Pin to short out the 2P socket on the mainboard, then power on, if successful, the beeper will beep twice, the LED shines in orange, remove the Short Pin, then read any two EM cards, after that the LED turns in red, means reset to factory default setting successfully. Of the two EM cards read, the first one is Manager add card, the second one is Manager delete card.
Remarks: Reset to factory default setting, the users' information enrolled is still retained. When reset to Factory setting, the two Manager cards must be re-enrolled.
.4. .5. .6.
9. Sound and Light indication
Operation status Reset to factory default setting Sleeping mode Operation successful Enter into programming mode Enter into setting Exist from programming mode Operation failed Open the door Alarm
LED Orange Red shines slow
Red shines Orange shines Red shines slow
Green shines Red shines fast
10. W2 Detailed Programming Guide
10.1User settings
There are 2 ways to add and delete users: A - By manager card; B - By remote control
A - By Manager card(The most convenient way)
To Add user by Manager Card
To Delete User by Manager Card
Enter into the programming mode firstly B- By Remote control
Manager add card Read user card Manager add card Cards can be added continuously.
Manager delete card Read user card Manager Delete card Cards can be deleted continuously.
Buzzer Two short ring
Short ring Short ring Short ring Short ring Three short ring Short ring Alarm
To Enter the programming mode
* Manager Password # 888888 is the default factory master code
Remarks: All the steps below must be done after enter into programming mode
To change the master code
To add a card user (Method 1) This is the faster way to enter cards using ID number auto generation. The card can be either be presented or input the 8 digit card number from the card can be manually entered
To add a card user(Method 2) This is the alternative way to enter cards using User ID Allocation. In this method a User ID is allocated to a card. Only one user ID can be allocated to a single card.
To delete a card user by card Number. Note users can be deleted continuously without exiting programming mode
To delete ALL users.
(Note: This option will delete all users but Manager Cards. Be careful with use)
0 New Password # Repeat New Password # The master code must be 6 8 digit number.
1 Read Card # or 1 Input Card number (8 digit) # Card can be added continuously without exiting programming mode. The card number is the last 8 digits of the number printing on the card.
1 ID number # Read Card # or 1 ID number # the Card number (8 digits) #
2 Read Card # or 2 Card number #
2 0000 #
10.2 Door setting
Lock Power Setting
Fail secure (Unlocked when power on)
Fail safe (unlocked when power is off) This is the factory default, 5 seconds:
4 0 99 # 0-99 is to set the door relay time 0-99 seconds.
5 0 99 # 0-99 is to set the door relay time 0-99 seconds.
Anti-submarine Settings Anti-submarine Disabled Anti-submarine Master Mode: Antisubmarine Auxiliary Mode
(Note: the detailed wiring diagram and illustrate,please refer to the Advanced application ) .
Door open detection
Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically. Door Forced Open warning. When used with an optional magnetic contact or built in magnetic contact of the lock, if the door is forced open, or if the door is opened after 120 seconds of the electro-mechanical lock not closed properly, the inside buzzer and alarm output will both operate.
To disable door open detection. (Factory default)
To enable door open detection
3 0 # 3 1 # 3 2 #
6 0 #
6 1 #
(Factory default)
Security Mode Setting
Read er Lockout & Alarm Output options. If there are 10 invalid cards in a 10
minute period, the Reader will lockout for 10 minutes or the alarm will operate for 10 minutes, depending on the option selected below.
Normal status (No lockout or alarm)
7 0 # (Factory default setting)
.6. .7. .8.
Reader Lockout Alarm Output
7 1 # 7 2 #
Door Interlock.
Door interlock disabled Door interlock enabled
8 0 # 8 1 #
Alarm output time
To set the alarm output t ime (0-3 minutes) Factory default is 1 minute
9 0~3 #
To remove the alarm
To remove the door forced open warning
To remove the door open too long warning
Read valid card or Master Code # Close the door or Read valid card
or Master Code #
To Unlock the door
To Unlock the door
Read user card (Note that Manager Card can't
be used to unlock the door.)
Attach: Advanced Application
1. W2 operating as a Controller
In this mode the W2 supports a Wiegand 26 bit input so an external Wiegand device with a 26 bit output can be connected to the Wiegand input terminals on the W2. Either an ID card reader (125 KHZ) or an IC card reader (13.56MHZ) can be connected to the W2. Cards are required to be added at the external reader, except where an external EM reader is used, in this case cards can be added at either reader. See figure 1
W2 controller
D0 D1
ALARM-
OPEN D_IN
+12V
GND VSS
L-
L+
ALARM+
J1
Green White Grey Yellow Brown Red Black Blue Purple Orange
wiegand reader
GND
+12V
D1 D0
reader plug
door detecting switch
figure 1
Em card Ic card HID card
Exit button
Power
DC12V/3A
-
+
­+
Alarm
-
Lock
+
2. W2 operating as a Wiegand Output Reader
In this mode the W2 supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit input. See figure 2
J1
D0 D1
+12V
GND
Controller
Powerful supply
Controller with wiegand 26 input
+
-
figure 2
Green White Grey Yellow Brown Red Black Blue Purple
Orange
D0 D1 ALARM­OPEN D_IN +12V GND VSS L-
L+
ALARM+
W2
3. Two W2 units interconnected for a single door
In this mode two W2 units are used for a single door , one for entry and the other for exit. Either device acts as the controller and reader at the same time. Users can be enrolled oneither of the devices. In this mode the user capacity for one door can be up to 20000. The setting of the two W2 units must be the same including the master code. See figure 3
D0 D1
ALARM-
OPEN D_IN +12V
GND VSS
L-
L+
ALARM+
indoor
J1
Green White Grey Yellow Brown Red Black Blue Purple Orange
door detecting switch
Exit button
­+ Alarm
DC12V/3A
­+
Power
+
Lock
-
J1
Green White Grey Yellow Brown Red Black Blue Purple Orange
W2 controller 2W2 controller 1
outdoor
D0
D1 ALARM­OPEN
D_IN +12V GND VSS L-
L+
ALARM+
figure 3
.9. .10. .11.
4. Two W2 units interconnected & interlocked for 2 doors
In this mode two W2 units are used for a two doors which are then interconnected and interlocked. In this mode the doors can be interlocked so that when door 1 is open, door 2 cannot be opened, and vise versa. The interlocked function is mainly used in banks, prisons, and other places where a higher level of security is required. See figure 4
Door 2
door detecting switch 2
W2 controller 2
J1
Green White Grey
ALARM­OPEN
Yellow
D_IN
Brown
+12V
Red
GND
Black Blue
VSS
Purple
L-
Orange
ALARM+
D0 D1
L+
W2 controller 1
D0 D1
ALARM-
OPEN D_IN +12V
GND VSS
L-
L+
ALARM+
J1
Green White Grey Yellow Brown Red Black Blue Purple Orange
Door 1
door detecting switch 1
Exit button 1
­+
Alarm 1
­+
Power
DC12V/3A
+
Lock 1
-
-
+
Alarm 2
Exit button 2
-
Lock 2
+
figure 4
5. Anti-submarine function for single door (3 1 #)
The connection diagram is as figure 1. Install one Wiegand reader (or a W2 without user information as reader) outside the door, connecting to one W2­Controller inside the door, which acts as the Anti-submarine Master unit. Of the two devices, they build up an anti-submarine system for single door. The operation and function is as below:
5.1 Set the needed function and enroll the User Cards on the inside W2 - Anti­submarine Master unit.
5.2 With the valid user card, the user can only enter the door from the outside reader, and exit from the inside W2 Controller. On the other hand, without entering record from the reader, the user can't exit from the controller inside, also, the user can't enter in and exit twice continuously.
6. Anti-submarine function for 2 doors The connection diagram is as Figure 4. Door 1 with one W2, and Door 2 with
one W2, set one W2 on Door 1 as the Anti-submarine Auxiliary unit (3 2 #), and set the other W2 on Door 2 as the Anti-submarine Master unit(3 1 #). They build up a two doors anti-submarine system, which is normally used for parking
lot......etc
The operation and function is as below:
6.1 Set the needed function and enroll the User Cards from W2 - Anti-submarine Master unit on Door 2.
6.2 With the valid user card, the user can only enter in from Door 1, and exit from Door 2. On the other hand, without entering record from the Auxiliary unit, the user can't exit from the Master unit or Auxiliary unit , also, the user can't enter in and exit twice continuously.
FCC WARNING
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE 1: Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
NOTE 2: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.