TRACEABLE® TWO-CHANNEL THERMOMETER INSTRUCTIONS
S Range: –58 to 2000°F (–50 to 1300°C) Resolution: 1° Accuracy: Probe: (2) Type-K thermocouple nak ed bead probe w it h 4' lead Sampling Rate : 2.5 times per second Display: 3½ digit LCD, 5/8 inches high (1.5C M ) Failsafe: Low battery indicat or Power: 9 volt alkaline battery Accessories: 12 inch Velcro wrist strap, rubberiz ed c ov er and a flip-out stand
FRONT PANEL QUICK REFERENCE
ON - Turns power on
OFF - Turns power off
MAX - Records and updates maximum values
HOLD - "Freezes" the display
F/C - Selects the tem perat ure t o be dis play ed
T1 - Dis play s tem perat ure reading f rom probe 1 T2 - Dis play s tem perat ure reading f rom probe 2
T1/T2 - Display s the dif f erenc e in temperat ure
OPERATION
Insert the probe plugs int o the recept ac les loc ated on the f ront of the therm om et er. The plugs and receptacles are k ey ed w ith small and large pins. M ak e certain t hat the plugs are inserted correct ly , do not f orc e them.
NOTE: Only one probe is required f or norm al operat ion. Press the ON button t o turn the unit on. Press the F/C button to display the temperat ure in Fahrenheit (°F w ill appear on t he
display) or Celsius (°C will appear on the dis play ). Press the T1 button t o display t he temperat ure of probe 1
(T1 appears on the display). Press the T2 button t o display t he temperat ure of probe 2
(T2 appears on the display). Place the probe tip in contac t wit h the material to be m eas ured and read the
temperature on the display.
MAX MODE
In the MAX mode, the therm om et er will display the highest t em perat ure reading achieved. It does not dis play the current temperat ure if it falls below the MAX reading.
Example: In the MAX mode
in either Fahrenheit or Cels ius
between probe 1 and probe 2
ROBES
P
The probes supplied are ultra-fas t res pons e T y pe-K t herm oc ouple nak ed bead probes with 4' leads and teflon insulat i on. Operat ing t em perat ure range f or t hes e thermocouples is or 500°F (260°C ).
An accessory stainless steel tri ple purpos e probe wi t h handle is av ailable. An accessory surfac e probe is als o available (see ac c es s ori es ).
Longer leads and extensions m ay be us ed. T he lead effec t for 164 f eet (50 met ers ) is generally less than 0.2°C w it h a limit of error of 2.2°C. Type-K wire and Type-K connectors mus t be used.
OFFSET ADJUSTMENT (Fine tuning) The offset controls are set at the fact ory to allow for the variations f ound in standard thermocouples. By adjus t ing t he offs et cont rols, f ound below t he thermoc ouple p lugs, you can optimize measurem ent ac c urac y for a part ic ular thermoc ouple (or pair of thermocouples) at a part ic ular t em perat ure.
ADJ
USTING FOR T1 OR T2 MEASUREMENTS
1. Plug in the T 1/ T 2 thermoc ouple and t urn t he t herm om et er ON . Press the appropriate T1/T2 key t o display reading.
2. Place t he t herm oc ouple in a k now n stable t em perat ure env ironm ent at or near the temperature you w is h to meas ure. Allow t he reading t o stabiliz e.
3. Slowly adjus t t he T1/T 2 OFFSET c ont rol that c orres ponds t o the selected input until the thermom et er reading m at c hes the tem perat ure of the k now n environment. (Allow s uf f icient t ime betw een adjus t m ent s to allow for measurement lag).
4. The c alibrat ion of t he thermom et er-t herm oc ouple c om bi nat ion is now opt im iz ed (fine-tuned) for measurem ent near t he t em perat ure us ed in step 2.
ZERO ADJUSTMENT FOR T1-T2 MEAS URE ME NTS :
1. Plug in both t he T 1 and T2 thermocouples.
2. Turn t he t herm om et er on and pres s the T1-T 2 button.
3. Place t he t herm oc ouples in a k now n stable t em perat ure env ironm ent at or near the temperature you w is h to meas ure and allow the reading to s t abiliz e.
4. Slowly adjus t eit her T 1 or T2 (but not both) of the OFF SET controls unt il the thermometer reads " 0". (Allow s uffic ient time bet w een adjus t m ents to allow f or measurement lag).
5. The t herm om et er-thermocouple combination is now s et for different i al temperature measurem ent near t he t em perat ure us ed in s t ep 3.
WRIST STRAP AND STAND
The unit is supplied with a Velcro w rist strap t hat att ac hes through t he t w o slots in the back of the rubberized casing. R em ov e the rubberized c ov er and s lip t he end of the strap through the slots, Velc ro side out, fast en at the buckle.
A bench stand is also supplied wit h t his unit and is part of the rubberiz ed c as e. Loc ate the rectangular opening at the bac k of the unit. Place your fingernail under the opening and flip the stand out. To close t he stand, simply snap it shut.
Select the desired input (T 1, T2 or T 1-T 2) then press the MAX button (MAX w ill appear on the display). The thermom et er w ill dis play the m ax imum t em perat ure reading on the LCD display. Press t he MAX key again t o exit MAX rec ording m ode.
HOLD Press the HOLD key to "freeze" the display at the c urrent T1, T2 or T1-T 2 reading (D­H will appear in the display). Press the HOLD k ey again to ret urn t o the current reading.
TEMPERATURE DIF FE RE NTIAL T1-T2 Press the T1-T2 key to display the difference in temperature betw een probe 1 and probe 2. This feature takes the tem perat ure being m eas ured at probe 2 and subt rac ts it from the temperature being m eas ured at probe 1 and dis play s t he differenc e. NOTE: Two probes must be connected to the unit to use this feature.
Traceable® is a registered tradem ark of Cont rol Company ©2008 Control C ompany. 92-4135-00 Rev. 2 052008
ACCESSORIES Control Cat. No. 4014—
1
Stainless Steel Triple Purpos e Probe, probe diam et er (15.2cm), overall lengt h 9" (22.9cm), cable length 50" (127cm).
Control Cat. No. 4008—
Surface Probe, flat dis k on end has a diamet er of 0.39" (1cm), ov erall l engt h 9" (23cm), cable length 36" (91. 4c m ).
Control Cat. No. 4028—
Ultra-fast response, nak ed bead t herm oc ouple. (ident i c al t o probe s upplied w it h unit ) cable length 48" (122cm).
Control Cat. No. 8039— Low-Temperature Probe - Stainless-steel with handle; t riple purpos e (li quids , air/ gas, and semi-solids), D im ens ions : diamet er 0. 17 inc h; stem lengt h 12 inc hes ; overall length 17 inches.
Control Cat. No. 8613— High-Temperature Probe - Ten-foot-long 0.19-inch diameter braided metal wire cable with smooth tip meas ures -73 to 982°C continuous or 1093°C short-term use.
DISPLAY MESSAGES: OL indicates that no probe is pres ent.
indicates that the battery is low and needs replac em ent (s ee bat t ery
replacement).
ALL OPERATIONAL DIFFICULTIES If this thermomet er does not f unction properly f or any reas on, pleas e replac e the battery with a new high quality battery (s ee “Battery R eplac em ent ” s ec t ion). Low battery power can occas ionally c aus e any num ber of “apparent” operat ional dif f ic ult i es . Replacing the battery w ith a new fresh bat t ery will solve m ost diffic ulties.
BATTERY REPLACEME NT:
" symbol will appear on the LCD dis play when t he battery needs replac em ent .
A " Before replacing the battery t urn t he unit off and unplug the probes. Slide t he unit out of its rubberized protectiv e c as ing. Rem ov e the three s c rews from t he back of the meter and lift off the front of the case. Remov e the exhau s t ed bat t ery and replace it with a new 9 volt alkaline batt ery. Replace t he f ront of the met er, insert t he screw s and slide the unit back into its rubberized c as ing.
/8" (0.32cm), probe length 6"
WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration, contact:
CONTROL COMPANY
4455 Rex Road
Friendswood, Texas 77546 USA
Ph. 281-482-1714 Fax 281-482-9448
E-mail sales@control3.com
www.control3.com
Control Company is ISO 9001 Quality-
Certified by DNV and ISO 17025 accredited
as a Calibration Laboratory by A2LA.
Traceable® is a registered tradem ark of Cont rol Company ©2008 Control C ompany. 92-4135-00 Rev. 2 052008
Loading...