TRACEABLE® LAB-TOP TIMER INSTRUCTIONS
SPECIFICATIONS:
Display: ½″ 6-digit LCD
Timing
Capacity: 23 hr, 59 min, 59 sec
Resolution: 1 sec
Accuracy: 0.01%
Size/Weight: 3¼ × 3¼ × 1¾″ / 4 oz
FEATURES
• Remarkable memory
• Stopwatch and clock
• Extra large buttons
• Designed to be seen from any angle
QUICK REFERENCE
1. AM/PM indicator - On in Clock mode. Indicates morning or
afternoon in 12-hour Clock mode.
2. Count-up indicator - On in Count-up mode. Flashes when counting
up if in Clock or Timer mode.
3. Timer indicator - On in Timer mode. Flashes when counting up if in
Clock or Timer mode.
4. Clock/Count-up/Timer display - Shows hours, minutes and
seconds in Clock mode, Count-up mode and Timer mode.
5. Time’s Up indicator - In Timer mode, flashes with alarm to indicate
time is up.
6. Memory indicator - In Timer mode, indicates memory function has
been activated.
7. Hour, Minute and Second buttons - Permit separately entering
hours, minutes and seconds in Clock mode, Count-up mode and
Timer mode.
8. Memory button - Permits entry and recall of preset time in Timer
mode.
9. Clear button - In Count-up mode and Timer mode, clears entry.
When using Memory function in Timer mode, clears Memory.
10. Start/Stop button - Stops and starts counting in Count-up and
Timer modes.
11. Clock/Count-Up/Timer switch - Selects Clock, Count-up or Timer
mode.
OPERATION
Selecting 12- or 24-hour Format
To select between 12- and 24-hour clock formats, slide the CLOCK/
COUNT-UP/TIMER switch to Clock, and press and hold the CLEAR
button for 2 seconds for the required format to appear. The “AM” or
“PM” indicator appears when the 12-hour format is selected.
1 2 3 4
5 6
7
9 8
11
10
5. To completely or temporarily stop timing cycle, press STOP. To
restart, press START.
6. To clear entry, press CLEAR. If Timer is running, press STOP first.
7. When in Clock mode or Count-up mode, stop the alarm by pressing
STOP.
8. To stop the alarm and stop and clear the “TIME’S UP” count up,
select Timer mode and press STOP.
Memory
1. Select Timer mode. Press memory to see if an entry is already
stored in “MEMORY”, press CLEAR to return display to “0:00:00”.
2. If the timer is running, press START/STOP to stop. Depress each of
the HR, MIN or SEC buttons to set the desired time and press
MEMORY to enter the preset time. The MEMORY indicator will only
show on the display in Timer mode when memory button is
depressed.
4. Press START. Timer will start counting down. When the set time
limit is reached the Alarm will sound, the Time’s Up indicator will
flash and Timer will count up from “0:00:00” to indicate elapsed
time since the alarm sounded.
5. Press START/STOP to stop count-up.
6. Press MEMORY to recall preset time.
4. Press CLEAR to cancel preset time or press START/STOP to begin
countdown again.
ALL OPERATIONAL DIFFICULTIES
If this unit does not function properly for any reason, replace the battery
with a new high-quality battery (see Battery Replacement section). Low
battery power can occasionally cause any number of apparent
operational difficulties. Replacing the battery with a new fresh battery
will solve most difficulties.
BATTERY REPLACEMENT
Erratic readings, a faint display, no display, or a battery icon on the
display are all indicators that the battery must be replaced. To replace
battery, remove the battery cover from the back of the timer. Remove
battery and replace with new AA alkaline battery. Match + and − on the
battery with the same signs on the timer. Replace battery cover.
Replacement battery Cat. No. 1111.
WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration, contact:
Setting Clock
1. Slide the CLOCK/COUNT-UP/TIMER switch to CLOCK.
2. Press and hold each of the HR, MIN or SEC buttons to set the
desired time.
Count-Up
1. Slide CLOCK/COUNT-UP/TIMER switch to COUNT-UP position.
2. Press START to start counting up.
3. To temporarily stop timing, press STOP.
4. Press START to restart.
5. If Count-up is already counting, press START/STOP to stop
count-up.
6. Press CLEAR to reset the digits to 0:00:00.
Setting Timer
1. Slide the CLOCK/COUNT-UP/TIMER switch to TIMER
2. If Timer is already running, press START/STOP to stop and then
CLEAR to clear entry.
3. Press and hold each of the HR, MIN or SEC buttons to set the
desired time.
4. Press START. Timer will start counting down. When the set time
limit is reached the Alarm will sound, the Time’s Up indicator will
flash and Timer will count up from “0:00:00” to indicate elapsed
time since the alarm sounded. The “TIMER” indicator will flash while
in Clock or Count-up mode to indicate the Timer is running.
CONTROL COMPANY
4455 Rex Road
Friendswood, Texas 77546 USA
Ph. 281-482-1714
Fax 281-482-9448
E-mail sales@control3.com
www.control3.com
Control Company is
ISO 9001 Quality-Certified by DNV and ISO 17025
accredited as a Calibration Laboratory by A2LA.
Cat. No. 5007
Traceable® Lab-Top Timer Instructions
92-5007-00
Rev. 1 062504
Traceable® is a registered trademark of Control Company
© 2004 Control Company