SPECIFICATIONS
14 programs per day or per week.
Minimum switching time: 1 minute
Ratings: ISA — I 2OVAC
Maximum resistive load: 1,800 Watts
After the correct time is entered, press the SET key to
end the clock setting. The word SET will be turned off
and ashing will stop. The display now shows the current
time and day as in Figure 3.
• Press the SET key. Adjust the second to 30 when the
SECOND is ashing using the left/right arrow keys.
• Press the SET key to complete the setting of count-
down time.
Figure 4
SETTING THE CLOCK
In the clock mode, the timer displays as shown in Figure
1. Note that the colon is ashing and the word CLOCK
appears on the LCD. To set the current time and day,
press the SET key, the DAY is ashing and the LCD
appears as shown in Figure 2. Use the left/right arrow
keys ( < > ) to select the current day, then press the SET
key. The HOUR is ashing, use the left/right arrow keys
to select the current hour, then press the SET key. Now
the MINUTE is ashing, use the left/right arrow keys to
select the current minute, then press the SET key. The
SECOND will ash. Press the right arrow key ( > ) to
set the time to the start of next minute, while press the
(left arrow key ( < ) to set the time to the start of current
minute.
For example, when the time displayed is 3:16:22 and the
second is ashing. Press the right arrow key will set the
time to 3:17:00. Press the left arrow key to set the time
to 3:16:00
To change from 12 to 24-Hour Display or vice versa,
press the RND key in the Clock setting mode.
During the setting procedure, If the left or right arrow key
is depressed for longer than I second, the key will repeat
itself. Depressing the key for a further 2 seconds will
increase the rate of repeat.
Figure 1
Figure 2
Figure 3
REVIEW AND SETTING PROGRAMS
The unit can be set for daily or weekly event. You can
choose the program to activate on a particular day, Monday to Friday, Monday to Saturday, Saturday to Sunday,
or everyday. You can set a maximum of 14 programs.
To review the various programs, push either the left/right
program arrow key. When the right arrow key is pressed,
the LCD display will scroll through all the programs in the
following sequence.
CLOCK-> PGM 1 ON -> PGM 1 OFF -> PGM 2 ON ->
PGM 2 OFF ->... PGM 14 ON-> PGM 14 OFF -> CD
PGM-> CLOCK
Press the left arrow key will have the same effect except
the sequence is reversed. Push both keys at the same
time will return to clock display.
The PROG symbol will display to denote the program
is being displayed. CD PROG will display to denote
the Count Down Program is displayed. A sample of the
program is shown in Figure 4. Please note the display
will show --:-- when the program is not set.
All programs can be reviewed by simply holding down
the left or right arrow keys: the display will scroll through
all the programs in sequence. Press the key one at a
time to view programs one by one.
EXAMPLE OF SETTING PROGRAM 1:
MO 8:15 ON / MO 15:45 OFF
In the above example, the timer will turn on at Monday
8:15 and off at 15:45. To set the timer on at 8:15, press
the right arrow key or left arrow key until PROG 1 ON
appears on the display, then press the SET key and the
word SET will display.
With the Day ashing, use the left or right arrow key to
select a day for which the program 1 to be turned on and
off. The day display will sequence through each day and
then MO – FR, MO – SA, SA – SU, MO – SU and then
repeat again.
In this example, the day would be Monday. Press the
SET key. When the hour is ashing, adjust the HOUR
to 8 using the left or right arrow key, then press the SET
key. When the Minute is ashing, adjust the MINUTE to
15 using the left right arrow keys, then press the SET key
to end the setting program. In Figure 4 the display shows
the timer before it’s being set and in Figure 5 the display
shows the timer after it’s been set.
Figure 5
To set the timer off at 15:45, follow the same steps as
setting the ON program.
Note; the HOUR and MINUTE can be set for the program
time but not the SECOND.
RANDOM FUNCTION
This timer has a built-in random function to automatically
turn the time on and off at random intervals. The timer
will stay on for approximately 10 to 26 minutes and off
26 to 42 minutes. By pressing the RANDOM key, the
symbol RND will ash indicating that it is active. When
the random function is active, all the preset programs
including the Count Down Programs are disabled and
remain disabled until the random generator is turned off
by pressing the RANDOM key again. Manual Override is
also disabled.
MANUAL ON/OFF
This timer can be turned on or off anytime (except when
Random/function is active) by using the ON/OFF key.
Press the ON/OFF key to turn the time on. Press the ON/
OFF key again to turn the timer off. The LED indicates
the timer is on or off. The ashing word ON or OFF
indicates that manual on/off mode is active.
The manual override mode will be cancelled when a
preset program or countdown program is activated. The
ON/OFF word on the clock display will then stop ashing.
COUNT DOWN TIMER (PROGRAM)
The countdown timer function can be used to turn the
timer on or off for a period from 1 minute up to 195 hours
59 minutes 59 seconds. To set the countdown time,
follow the example shown below. Example: Setting the
countdown time to stay on for 1 hour 10 minutes 30
seconds.
• Display the CD PROG using the left or right arrow
keys. (While clock is displayed, push the left arrow
key once will display CD PROG.)
• Press the SET key. The word SET will display and
either ON or OFF will ash.
• Select ON using the left/right arrow key.
• Press the SET key. Adjust the hour to 1 when the
HOUR is ashing using the left/right arrow keys.
• Press the SET key. Adjust the minute to 10 when the
MINUTE is ashing using the left/right arrow keys.
Figure 6
The Countdown Timer is now set to turn on or off for 1
hour 10 minutes 30 seconds as shown in Figure 6. Press
the CD key anytime to activate the count down. The
display will show the time counting down when the CD
PROG symbol is displayed, until it reaches zero. When
time is up, the time will turn itself off.
The count down will not start when the random function
is active. Regular program is disabled during the count
down period. Activating Random function or Manual On/
Off will cancel the count down operation.
DISABLE / MASTER DISABLE FUNCTION
This function allows you to disable and enable any or
all of the 14 preset ON/OFF programs and CD Program
using the ON/OFF key.
To disable a program, display the program or CD Program you wish to disable using the left/right arrow key,
then press the SET key. The display is ashing and the
word SET is displayed, press the ON/OFF key to disable
the program, the X symbol will appear to indicate that
that particular program is disabled as shown in Figure 7.
Figure 7
Note: The display is still ashing and if there’s no
changes to be made on the preset program, press the
SET key, until the display is not ashing. Use this function to disable as many available preset programs as you
choose.
To disable all programs, press the SET key while in clock
display. Then press the ON/OFF key to disable all the
preset programs when the display is ashing. The X
symbol will appear on the clock display indicating that all
preset programs are disabled.
Please note that CD Program will not be affected by the
master disable.
To cancel the disable function, just repeat the same
procedure to turn off the X symbol.
AUTO-RETURN TO CLOCK DISPLAY
If the unit is left idling more than 1 minute during
programming or displaying another mode, the display
will return to clock and the programming operation is
cancelled. However, if the display is showing count down
time in progress, auto-return will riot activate until count
down is nished.
LED INDICATOR
The LED indicator shows the status of the timer. If the
LED is lit, the timer is on and if the LED is not lit, the timer
is off. Note that the timer’s status can also be seen in the
CLOCK mode, by the word ON or OFF. The LED will only
light when the timer is plugged into an electrical outlet.
RESET
The RESET key is located on the top-right hand corner
of the function board. Use a round object such as a
ball-point pen to push the reset key while the SET key
is pressed. Then release the RESET key rst before the
SET key. After reset, all preset programs are erased from
timer’s memories.
ABNORMAL DISPLAY
When an abnormal display or a blank display appears on
the timer, use the above Reset procedure, otherwise the
timer may not work properly. Be sure that the rechargeable battery Is adequately charged.
WARRANTY, SERVICE, OR
RECALIBRATION
For warranty, service, or recalibration, contact:
CONTROL COMPANY
4455 Rex Road
Friendswood, Texas 77546 USA
Ph. 281 482-1714
Fax 281 482-9448
E-mail sales@control3.com
www.control3.com
Control Company is ISO 9001
Quality-Certified by DNV and
ISO 17025 accredited as a
Calibration Laboratory by A2LA.
TRACEABLE
COUNTDOWN
CONTROLLER
INSTRUCTIONS
®
©2014 Control Company. 92-5095-00 Rev. 3 060214
Traceable
is a registered trademark of Control Company.
®