SPECIFICATIONS
Display: 2
Timing resolution: 1 second
Timing accuracy: 0.01%
Temperature range: 23 to 122 °F (–5 to 50 °C)
Temperature resolution: 0.5
Size/Weight: 9¼ x 9¾ x 1″, 19 oz
FEATURES
• 12-/24-hour selectable
• °F/°C selectable
• Giant, easy-to-read display
• No AC requirements (runs on two AA batteries)
• Timing traceable to NIST
QUICK REFERENCE
1. Month & Date display Constantly shows current month, date and day
of the week.
2. Giant Clock display Facilitates viewing time of day.
3. Temperature display Constantly
shows current room temperature.
4. Day-of-the-Week display Constantly
shows current day of the week.
5. Temperature sensor Samples room
temperature to provide updated
readings.
6. MONTH/HOUR button Permits setting
the current month while the clock is in
Calendar mode. While in Clock mode it
advances the Hour setting.
7. DATE/MIN button Permits setting the
current date while the clock is in
Calendar mode. While in Clock mode
it advances the Minutes setting.
8. YEAR/12/24 HR button Permits
setting the current year while the
clock is in Calendar mode. Toggles
between 12- and 24-hour time
formats while in clock mode.
9. °C/°F button Selects between
degrees Celsius (°C) and degrees
Fahrenheit (°F).
10. Battery compartment Accommo-
dates two AA batteries.
11. LOCK/CLOCK/CALENDAR
switch Permits setting the Clock and
Calendar functions. Also pro-vides
protection from accidental adjustment while in the Lock position.
OPERATION
SETTING CALENDAR
This unit constantly displays the current month, date and day of the week.
To set the calendar:
1. On back of the unit, slide the LOCK/CLOCK/CALENDAR switch to the
CALENDAR position.
2. Press MONTH, DATE, and YEAR buttons until the correct setting is
displayed.
3. Slide the LOCK/CLOCK/CALENDAR switch to the LOCK position.
NOTE: An incorrect calendar setting will automatically be adjusted (i.e.,
April 31 will be adjusted to April 1 and with the exception of a Leap Year –
February 29 will be adjusted to February 1).
NOTE: Year is not viewable in CLOCK or LOCK mode. To view year, switch
to CALENDAR position.
SETTING TIME
Calendar/Thermometer Clock displays the current time of day in either 12or 24-hour format. To set:
1. Slide the LOCK/CLOCK/CALENDAR switch to CLOCK position.
2. On back of the unit, press the 12/24 HR button to select between a 12-
hour (AM/PM) or a 24-hour (international) time format.
3. Press HOUR and MIN buttons until the current time is displayed.
4. Slide the LOCK/CLOCK/CALENDAR switch to the LOCK position.
3
″
/8
LCD
o
Figure 1 Calendar/Thermometer
Clock front view
Figure 2 Calendar/Thermometer
Clock back view
SETTING TEMPERATURE
This unit constantly displays the current room temperature in either degrees
Celsius (°C) or degrees Fahrenheit (°F). To choose a temperature scale:
• On back of the unit, press
°C/°F button until the desired
temperature scale (°C or °F) is
displayed on front of the unit.
• Each press of the °C/°F button
toggles between degrees Celsius
and degrees Fahrenheit.
ON A WALL
This clock is supplied with a screw for
hanging on a wall. For best viewing of the
LCD, hang the clock at a minimum height
of 6 foot 5 inches to obtain the viewing
angle of approximately 70° as indicated.
CARE AND MAINTENANCE
This product is engineered to provide years of satisfactory service if handled
carefully. Here are a few precautions:
1. Never use chemicals such as benzene or petroleum-based solvents for
cleaning, as they may damage the case.
2. Do NOT expose the clock to direct sunlight, spotlight, or extremely hot
or cold temperatures.
3. Clean the case by using a cloth slightly dampened with water and wipe
dry.
OPERATIONAL DIFFICULTIES
If this clock does not function properly for any reason, replace the batteries
with new, high-quality batteries (see “Battery Installation” section). Low
battery power can occasionally cause any number of “apparent” operational
difficulties, such as screen dimming or difficulty in reading the display.
Replacing the batteries with new, fresh batteries will solve most difficulties.
BATTERY REPLACEMENT
Erratic readings, a faint display, or no display are all indicators that the
batteries must be replaced. Lift the battery compartment door on back
of unit. Remove the exhausted batteries and replace with two new AA
alkaline batteries. Replace the battery compartment door. The clock will start
running from 12:00 A.M. January 1, 1996. Replacement battery Cat. No. 1111.
WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration contact:
CONTROL COMPANY
4455 Rex Road
Friendswood, Texas 77546 USA
Ph. 281-482-1714 Fax 281-482-9448
E-mail sales@control3.com
www.control3.com
Control Company is ISO 9001 Quality-Certified
by DNV and ISO 17025 accredited as a
Calibration Laboratory by A2LA.
Cat. No. 1072
Traceable® Calendar/Thermometer Clock Instructions
92-1072-00
Rev 2 120505
Traceable® is a registered trademark of Control Company
© 2005 Control Company