SPECIFICATIONS
WWVB Signal Reception—
Frequency: 60 kHz
Rate: Every 3 hours
Temperature Range—
Ambient: 32.0 to 122.0° F / 0.0 to 50.0° C
Remote: -4.0 to 140.0° F / -20.0 to 60.0° C
Resolution: 0.1°
Temperature Display Update Rate—
Ambient Display: 16 seconds
Remote Module Display: 16 seconds
Remote Display on Main Unit: 3 minutes
Remote Module Transmission—
RF Frequency: 433 MHz
Rate: Every 3 minutes
Distance: Up to 30 meters (100 feet)
INITIAL SET-UP
Remote Module—
(Battery Installation, °F/°C Selection)
GIANT-DIGITS™ ATOMIC CLOCK WITH
and the main unit may be set to display °F and vice-versa. Changing the unit of
display on one does not affect the display of the other.
SET-UP TIPS
1. Insert batteries into the remote module before the main unit.
2. Place the main unit as close as possible to the remote unit. This will ensure easier
reception of signal.
3. Position the remote module within the effective transmission range (up to 30
meters/100 feet).
Note: The effective range is significantly affected by building materials and by where
the main unit and remote modules are positioned. Try various setups to insure proper
signal reception.
Important: Though the remote module is weather resistant, it should be placed away
from direct sunlight, rain, or snow.
SIGNAL RECEPTION
Atomic Clock—
The unit contains a pre-tuned internal radio receiver that receives a 60 kHz frequency
signal generated by the U.S. Atomic Clock. The U.S. Atomic Clock is located in
Boulder, Colorado and is operated by NIST (National Institute of Standards and
Technology).
Once the batteries have been installed, the unit automatically activates its receiver.
Upon successful reception of the signal from the Atomic Clock, the correct time-of-day
and date will appear on the display.
1. Lift the stand, located on the back of the remote module, to expose the battery
cover and the RESET and °C/°F buttons.
2. Remove the battery cover.
3. Insert the batteries according to the polarities shown by the battery compartment
illustration.
4. Replace the battery cover.
5. Select the temperature display unit for the remote module by pressing the °C/°F
button.
Note: The temperature display unit of measure (°C/°F) of the remote module and the
main unit are independent of each other. The remote module may be set to display °C
and the main unit may be set to display °F and vice-versa. Changing the unit of
display on one does not affect the display of the other.
Main Unit—
(Battery Installation, °F/°C Selection)
1. Prior to installing the batteries into the main unit, insure the TIME SET switch,
located on the back of the unit, is set to the LOCK position.
2. Remove the battery cover.
3. Insert the batteries according to the polarities shown by the battery compartment
illustration.
4. Replace the battery cover.
5. Select the temperature display unit by pressing the °C/°F button.
Note: The temperature display unit of measure (°C/°F) of the remote module and the
main unit are independent of each other. The remote module may be set to display °C
The unit may not receive a signal immediately. It may take as long as 72 hours to
receive a complete signal from the Atomic Clock. The clock will attempt a signal
reception for 10 minutes every 3 hours until it successfully receives the signal from the
atomic clock. While the unit is attempting to receive a complete signal for the first
time, the clock may be set manually (see the “Manual Clock/Calendar Setting”
section). Best reception often occurs between midnight and 4 am.
The successful reception of the Atomic Clock signal is dependent upon the positioning
and location of the unit. Insufficient signal strength or external electrical interference
may prevent the unit from receiving a complete signal. The main causes for poor
reception are heavily reinforced concrete and steel structures and/or placement of the
unit close to video or PC monitors. There are certain areas of the Eastern United
States where urban interference or signals from the United Kingdom’s Atomic Clock
may distort or interfere with the signal from the U.S. Atomic Clock.
Atomic Clock Signal Indicators
Indicates completed signal reception and synchronization with the Atomic
Clock.
Flashing, indicates that the unit is attempting to receive the signal from the
Atomic Clock.
Not flashing, indicates signal has not been successfully received.
If this symbol appears for more than 72 hours, the unit should be
repositioned for better reception.
Remote Module—
Once the batteries have been installed in the remote module, the unit automatically
activates its transmitter. Once the batteries have been installed in the main unit, the
main unit automatically activates its receiver. The clock will attempt to receive the RF
signal from the remote temperature module for 5 minutes. Upon successful reception
of the remote module’s signal, the display will show the remote temperature.
If no signal is received from the remote module, the main unit display will show “- - -”
for the remote temperature. Press the RE-SYNC button, located on the back of the
main unit, to initiate signal reception again.
The successful reception of the remote module’s RF signal is dependent upon the
positioning and location of the remote module. Insufficient signal strength or external
electrical interference may prevent the unit from receiving the signal. The main causes
for poor reception are heavily reinforced concrete and steel structures and/or
placement of either unit close to video or PC monitors.
Important: The temperature display on the remote module is updated every 15
seconds, the remote temperature display on the main unit is updated every 3
minutes. The difference in update rates may account for discrepancies between the
reading shown on the main unit and that on the remote module. This is normal,
especially when the temperature at the remote module is fluctuating.
Remote Module Signal Indicators
Flashing, indicates the unit is attempting to receive the signal from the remote
module.
Not flashing, indicates successful signal reception from the remote module.
Indicates a signal has not been successfully received from the remote module.
SELECTING THE TIME ZONE
Slide the time zone switch, located on the back of the main unit, to the correct position
for the desired time zone:
PST = Pacific Standard Time
(“PST” will appear to the left of the time-of-day display.)
MST = Mountain Standard Time
(“MST” will appear to the left of the time-of-day display.)
CST = Central Standard Time
(“CST” will appear to the left of the time-of-day display.)
EST = Eastern Standard Time
(“EST” will appear to the left of the time-of-day display.)
DAYLIGHT SAVING TIME (DST)
Slide the DST switch, located on the back of the main unit, to the desired position.
To observe Daylight Savings Time, set the switch to ON. To disregard Daylight
Savings Time, set the switch to OFF.
SELECTING 12 OR 24 HOUR TIME DISPLAY
Each press of the 12/24HR button, located on the back of the main unit, will toggle the
time-of-day display between 12 hour (AM/PM) and 24 hour (military) time. The display
will indicate AM and PM when in 12 hour time-of-day display mode.
MANUAL CLOCK/CALENDAR SETTING
1. Slide the TIME SET switch, located on the back of the main unit, to TIME SET.
The time-of-day will flash.
2. Set the hour by pressing the HR button.
3. Set the minute by pressing the MIN button.
4. With the desired time-of-day on the display, slide the TIME SET switch to
CALENDAR. The year will flash.
5. Set the year by pressing the YEAR button.
6. Set the month by pressing the MONTH button.
7. Set the day number by pressing the DATE button. (Once the year, month and day
number have been selected, the main unit will display the proper day-of-week
once the TIME SET switch is set to the LOCK position.)
8. With the desired date on the display, slide the TIME SET switch to the LOCK
position.
NOTE: Manual changes made will be automatically overridden with the next complete
signal reception from the Atomic Clock.
MANUALLY INITIATING SIGNAL RECEPTION
Atomic Clock—
If you have moved the main unit from a location where it was receiving a strong
complete signal, it is recommended that you manually initial signal reception to insure
that the unit will receive a complete signal in its new location.
To manually initiate signal reception:
Press and release the WAVE button, located on the back of the unit. will flash on
the display, indicating that the unit is attempting to receive the signal from the Atomic
Clock. (See the “Signal Reception - Atomic Clock” section.)
Remote Module—
If you have moved the main unit or the remote module, it is recommended that you
manually initial signal reception to insure that the main unit will receive a signal from
the remote module.
To manually initiate signal reception:
Press and release the RE-SYNC button, located on the back of the main unit. will
flash on the main unit display, indicating that the unit is attempting to receive the signal
from the remote module. (See the “Signal Reception - Remote Module” section.)
WALL MOUNT AND BENCH STAND
Both the main unit and remote module have built in bench stands. The units may also
be wall mounted. See the following illustrations.
RESET BUTTON
Located on both the main unit and remote module, this button is only used when either
unit is operating in an unfavorable way or malfunctioning, most commonly caused by
ESD (electrostatic discharge) or radio interference. To reset either unit, press and
hold down the button for 2 seconds. All settings will return to default values. Pressing
the RESET button has a similar effect as removing and re-installing the batteries.
ALL OPERATIONAL DIFFICULTIES
If either unit does not function properly for any reason, try resetting both units (see
the “Reset Button” section). If the units do not function properly after a reset,
replace the batteries with new high quality batteries (see the “Battery Replacement”
section). Low battery power can occasionally cause any number of “apparent”
operational difficulties. Replacing the battery with a new fresh battery will solve
most difficulties.
BATTERY REPLACEMENT
Erratic readings, faint readings, or no display are all indications that the batteries must
be replaced. See the “Initial Set-up” section for instructions on replacing the batteries.
Warranty, Service, or Recalibration
For warranty, service, or recalibration, contact:
CONTROL COMPANY
4455 Rex Road
Friendswood, Texas 77546 USA
Ph. 281-482-1714
Fax 281-482-9448
E-mail sales@control3.com
www.control3.com
Control Company is ISO 9001 Quality-Certified by
DNV and ISO 17025 accredited as a Calibration
Laboratory by A2LA.
Control Company Cat. No. 1087
Traceable® is a registered trademark of Control Company
© 2008 Control Company 92-1087-00