TRACEABLE® 300-MEMORY STOPWATCH INSTRUCTIONS
SPECIFICATIONS
Display: ¼” digits, 3-line LCD display
Range: 9 hrs, 59 min, 59 sec, 99/100
Resolution: 1/100 sec
Accuracy: 0.001%
Features: Continuous Timing, Lap/Split Timing, Countdown/Count up Timing,
CONTROLS
Listed below are the unit’s buttons along with their function in the various
stopwatch modes.
START/STOP Button
1. Stopwatch – starts and stops timer
2. Speed – starts and stops speed function
3. Stroke – starts and stops stroke function
4. Time/Calendar – advance digits when setting time of day
5. Alarm – silences alarm
6. Pacer – starts and stops pacer function
7. Timer – starts and stops timer function
RESET/LAP SPLIT Button
1. Stopwatch – with timer running records a lap/split time. With timer stopped
2. Speed – when in value setting mode advances through fields in order to set
3. Stroke – resets stroke count to 2400
4. Time/Calendar – switches hourly reading from 12- or 24-hour setting
5. Alarm – enable/disable alarm
6. Pacer – sets pacer value
7. Timer – when timer is stopped, resets the timer run value to the timer set
RECALL Button
1. Stopwatch – recalls memory data for lap/split timing
2. Speed – hold for 2 seconds to activate value setting mode
3. Stroke – n/a
4. Time/Calendar – hold for 2 seconds to activate time/date setting mode
5. Alarm – hold for 2 seconds activate daily alarm setting mode
6. Pacer – n/a
7. Timer – hold for 2 seconds to activate value setting mode
MODE Button
Advances display through the stopwatch functions.
OPERATION
Entering Timing Modes
1. Pressing the MODE button will advance the screen through the seven
2. Repeatedly pressing the mode button scrolls through the functions in the
Clearing the display
The RESET / LAP SPLIT button will clear the following displays:
1. Stopwatch – resets the timer to zero
2. Speed – resets the timer to zero
3. Stroke – resets the timer value to 2400.0
4. Pacer – starts and stops pacer function
5. Timer – after timer is stopped, will reset the timer to set value
Clock Operation/Setting Time-of-Day & Date
1. Press the MODE button to cycle through the displays until Time/Calendar
2. Hold the RECALL button for 2 seconds, a beep will sound and the AM/PM
3. The RESET/LAP SPLIT button will cycle through the Time/Calendar display
4. While in each of the above time measurements, each press of the
5. The “day of the week” feature will update automatically as the year, month
6. Save the set time and calendar reading by pressing RECALL. The display
Daily Alarm Operations
1. Press the MODE button to cycle through the displays to the Alarm display.
2. Hold down the RECALL button for 2 seconds, a beep will sound and the
3. Press the START/STOP button to advance the hourly setting of the alarm.
4. Press RESET to advance the minute.
5. Press START/STOP to advance the digits.
6. Press RECALL to set alarm.
Speed Timing, Stroke Timing, Pacer Timing, Time/Calendar
display, Daily Alarm
resets display to zero
values
value
functions of the stopwatch.
following order: Stopwatch (Chron), Speed, Stroke, Time/Calendar, Alarm,
Pacer and Timer. With the exception of the Time/Calendar mode, an
identifying screen that displays for 2 seconds precedes each of modes.
display is reached.
icon and hour digit will flash.
in the following order: hours, minutes, seconds, year, month and day.
START/STOP button will advance one increment at a time, holding the
START/STOP button down enables rapid advancement.
and day are changed.
will stop flashing.
AM/PM icon and hour digit of the alarm display will flash.
An “A” or “P” will be displayed indicating AM or PM alarm time.
7. Press the RESET/LAP SPLIT button for 2 seconds to toggle the alarm icon
on and off. The (((•))) icon indicates alarm is on.
8. When the alarm time is reached an audible alarm will sound for 30
seconds, or may be manually silenced by pressing the RESET/LAP SPLIT
button.
Pacer Operation
1. Press the MODE button to cycle through the display modes to the Pacer
display. The last value set will be displayed on the screen.
2. Pressing the RESET/LAP SPLIT button will advance through the pacer
values. The Pacer timer may be set at the following values: 5, 10, 20, 30,
40, 50, 60, 80, 100, 110, 120, 140, 160, 180, 200 and 240. These values
represent counts per minute (i.e., Pacer Value 20 = 20 beeps per minute)
3. Press the START/STOP button to start the pacer timer. The flashing
PACER icon under the timer value indicates the timer is activated. An
audible alarm will sound representing the set pacer value.
4. The pacer values can be changed while the timer is in operation. The pacer
alarm will change accordingly.
5. Pressing the START/STOP button will turn off the pacer timer.
Timer - Countdown/Count up Mode
1. Press to MODE button to cycle through the display modes to the Timer
display.
2. Hold down the RESET/LAP SPLIT button for 2 seconds, a beep will sound
and the timer will toggle between countdown/countup mode (TIMER) and
repeat countdown mode (TIMER).
3. To set countdown/countup mode, toggle to the TIMER icon.
4. The top line of the 2-line display represents the time set value. The
maximum setting for this mode is 9 hours, 59 minutes and 59 seconds.
5. To set the time value hold the RECALL button for 2 seconds. A beep will
sound and the hourly time increment will flash. Pressing the RESET/ LAP
SPLIT button will scroll through each time increment in the following order:
hours, minutes and seconds.
6. Each press of the START/STOP button will advance one increment at a
time, holding down the START/STOP button enables rapid advancement.
7. Press the RECALL button to lock in the countdown value.
8. Press the START/STOP button, timing will begin and the timer icon will
show an arrow pointing down indicating countdown mode.
9. If a pause in the timing operation is required press the START/STOP
button to “freeze” the display at the current reading (time-out). To resume
time at the point it was stopped, press the START/STOP button again
(time-in). An unlimited number of timeouts may be taken.
10. When the set countdown time value has been reached, a 30-second alarm
will sound. The alarm and timer can be manually stopped by pressing the
START/STOP button. Pressing the RECALL or RESET/LAP SPLIT will
silence the alarm and allow continued timing.
11. The TIMER icon will display indicating the count up mode. The timer will
show time passed since alarm time and will continue timing to 9 hours, 59
minutes and 59 seconds.
Timer - Repeat Countdown Mode
1. With the display in timer mode, hold down the RESET/LAP SPLIT button
for 2 seconds. A beep will sound and the Repeat Counter display (00) will
appear in the upper left corner of the display. The TIMER icon at the
bottom of the screen indicates repeat countdown mode.
2. To set the time value hold the RECALL button for 2 seconds. A beep will
sound and the hourly time increment will flash. Pressing the RESET/ LAP
SPLIT button will scroll through each time increment in the following order:
hours, minutes and seconds.
3. Each press of the START/STOP button will advance one increment at a
time. Holding down the START/STOP button enables rapid advancement.
4. Press the RECALL button to lock in the countdown value.
5. Pressing the START/STOP button will begin the countdown. To stop the
countdown, press the START/STOP button and the STOP icon will appear
to the left of the countdown line.
6. If a pause in the timing operation is required, press the START/STOP
button to “freeze” the display at the current reading (time-out). To resume
time at the point it was stopped, press the START/STOP button again
(time-in). An unlimited number of timeouts may be taken.
7. An alarm will sound for 3 seconds when the set timer value has been
reached and the display will return to the set time value.
8. The repeat mode allows continuous timing of the set timer value. The
repeat counter will show the number of times that the set timer value has
been reached. The counter can record up to 99 laps.
Single Action Timing
1. Press the MODE button to advance the display to the stopwatch mode
indicated by the CHRON screen.
NOTE: If there is a measured time event showing on the SPEED display, the
CHRON stopwatch mode will not be displayed. The SPEED display must be
reset to zero to use the stopwatch functions.
2. This CHRON screen consists of a 3-line display indicating split timing on
the top line, lap timing on the middle line, and stopwatch timing on the
bottom line.
3. Press RESET to set the counter to zero.
4. The START/STOP button will begin stopwatch timing.
1
5. If a pause in the countdown or countup timing operation is required press
the START/STOP button to “freeze” the display at the current reading
(time-out). To resume time at the point it was stopped, press the
START/STOP button again. An unlimited number of timeouts may be
taken.
Cumulative and Lap/Split
Cumulative split time measures partial times while the stopwatch continues to
measure total elapsed time. Lap/Split time measures each round of timing
(noncumulative).
1. Timing operation
i. Hold the RESET button for 2 seconds, a beep will sound and all 3 lines on
display will reset to zero.
ii. Press the START/STOP button to start timing. The bottom line on display
will begin timer operation.
iii. Press the LAP/SPLIT button to record Lap 1 on the stopwatch. (001) will
display at the upper left of the screen. The cumulative time will show on the
top line of the display. The time length of Lap 1 will show on the middle line
of the display. The bottom line of the display will continue normal timing
operations.
iv. Each press of the LAP/SPLIT button will record and display the next
succession of laps. A total of 300 lap/split times can be entered into the
stopwatch memory.
v. Press the START/STOP button when the timing event is completed.
2. Lap/Split Memory Function
After the timer has been stopped and the event is complete, various memory
functions can be recalled.
i. Press the RECALL button, the word RECALL will appear under the lap
counter at the upper left of the display.
ii. With each press of the RECALL button various stored data will be
displayed and the data information named under the timer counter.
iii. The various memory functions are listed below in the sequence they
appear:
Fastest Timed Lap - FAST appears under the lap counter, the number of the
fastest lap appears in the counter, the lap time shows on the middle line of
display and the top line shows the cumulative time of the lap.
Slowest Timed Lap - SLOW appears under the lap counter, and as stated above,
the display shows the recorded time of the slowest lap – lap number, lap time
and cumulative time.
Averaged Timed Lap - AVG appears under the lap counter, the lap counter will
display the number of laps recorded in the Recorded Lap/Split Times.
Recorded Lap/Split Times –(001), (002), etc.
Each lap time data will be shown in the order in which they were recorded. The
lap counter will show the lap number, top line displays the cumulative time and
the middle line shows the lap time.
3. To clear the memory press the MODE button, Recall will no longer be
displayed, then press RESET.
Speed Mode
1. Press the MODE button to advance the display to the speed mode.
NOTE: The unit is “per hour” therefore speed = set distance x 3600
seconds. The maximum display of speed is 9999.999, if any calculated
speed is over this value, Error will show in the middle row and speed value
will not be stored into memory.
2. Press and hold the RECALL button for 2 seconds until Km is flashing.
3. Press the RESET button to move to the top line of the display, which is
distance. Continuing to press moves the blinking digit.
4. Press the START/STOP button to advance digits to the correct distance.
Press RECALL to confirm the entry.
5. Press the START/STOP to begin timing.
6. Press the LAPSPLIT for the laps.
7. Recalling memory in speed mode:
i. When the stopwatch is stopped; the following will show with each
press of the RECALL button. (top row = LAP, middle row = SPEED,
bottom row = TOTAL TIME). Fastest speed/lap, slowest speed/lap,
average speed/lap and then each speed/lap stored in memory.
ii. When the stopwatch is running; the same is displayed except that the
time continues to run on the bottom row.
Stroke/Frequency Measuring Mode
This mode calculates frequency by taking 3 strokes (cycles) within a time period
and then calculating the expected number of cycles if that action is continued for
1 minute.
1. Press MODE button to show the Stroke /Frequency Measuring Display.
2. Start the measurement by pressing the START/ STOP button. Then press
the START/STOP button after the third stroke is made. The number of
strokes per minute will be displayed on the lower row, while the
measurement time will show on the upper row.
NOTES
1. Pressing the START/STOP button faster than 1/8 second (0.125 sec) will
cause an Error to display indicating the overflow of the showable value.
2. Pressing the START/STOP button longer than 18 seconds will cause an
Error to display which indicates the time period is too long.
3. Pressing the RESET button while the measurement is stopped or while an
Error is shown, causes the digits to be reset to 2400.
ALL OPERATIONAL DIFFICULTIES
If this unit does not function properly for any reason, replace the battery with a
new high-quality battery (see “Battery Replacement” section). Low battery power
can occasionally cause any number of “apparent” operational difficulties.
Replacing the battery with a new fresh battery will solve most difficulties.
BATTERY REPLACEMENT
An indication that the battery must be replaced would be erratic readings, a faint
display, no display, or if all icons/digits of the display are highlighted. Remove the
screws on the back of the unit and remove the back cover. Remove the screw
holding the battery bracket in place. Remove the exhausted battery and replace
with a new battery. Secure the battery bracket into place, replace the back of the
unit and replace and tighten screws. Replacement battery Cat. No. 1005
WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration, contact:
CONTROL COMPANY
4455 Rex Road •
Friendswood, Texas 77546 • USA
Ph. 281 482-1714 •
Fax 281 482-9448
www.control3.com • sales@control3.com
Control Company is ISO 9001 Quality-
Certified by DNV and ISO 17025
accredited as a Calibration Laboratory
by A2LA.
Traceable® is a registered trademark of Control Company
© 2007 Control Company
92-1052-00 Rev. 3 122707
2