Ensure that the location and intended use meet the
1
following criteria:
DO (OK, Normal) DON’T
Install in accordance with all
national and local electrical codes.
Wall box size required depends
on your wiring. The 6-button key­pad alone needs a depth of 2.5 inches. To calculate the total depth required, add 2.5 inches to the amount of space recom­mended in the NCC Code for your configuration.
The range and performance of
the control system is highly dependent on the following:
Distance between devices
Layout of the home
Walls separating devices
Electrical equipment
located near devices
If installing a
multi-unit 6-but­ton keypad, Do NOT continue until you have read “Multi-Unit Installations” on page 2.
Do NOT use
where total watt­age is under 25 watts.
Do NOT exceed
maximum load rating of dimmer (which is 1000W for a single unit, if both side tabs are in tact).
Supported Models, Features, and Fixtures
This installation guide covers these 6-button keypad models:
LDZ-101-W Wireless 6-Button Keypad (802.15.4)
LDZ-101-B Wireless 6-Button Keypad (802.15.4)
LDZ-101-A Wireless 6-Button Keypad (802.15.4)
The Control4 Wireless 6-Button Keypad can be configured as a peer­to-peer device or as part of the Control4 network. It can be programmed to do any supported network event (such as controlling a group of lights, a music zone, or a security system) or can simply be used to replace 3 light switches. It installs in a standard wall box using typical wiring standards and gets power from a nearby power outlet or light switch. It communicates to the system using a wireless connection and features a tri-color LED for system feedback. It supports lighting fixtures with the following load requirements:
120 Volt incandescent (all types)
120 Volt halogen (all types)
120 Volt magnetic low voltage
(all types with 70 percent or greater load factor)
120 Volt electronic low voltage (dimmable only)
120 Volt fluorescent light fixtures (dimmable only)
WAR NING!
To reduce the risk of serious injury or death, turn all power OFF before installing this product. Using this product in a manner other than outlined in this document voids your warranty. Further, Control4 is NOT liable for any damage incurred with the misuse of this product. See “Limited 1 Year Warranty” on page 4. This product generates heat. The room must have adequate ventilation or heat dissipation ability. Do NOT use this device to control a device with a non­dimmable load. You should only use it with devices that have dimmable feature support.
To avoid injury or death, turn OFF local
2
electrical power. To turn off the power, either flip the circuit breaker or remove fuse from fuse box. To ensure the wires do NOT have power running to them, use an inductive voltage detector.
Prepare and identify all wires. Identify the wires in your
3
wall box. Straighten the wire ends. With a wire cutter, cut off the bare wire just below the plastic insulation on all wires. Use a wire stripper to strip off about 3/8-inch of the insulation.
IMPORTANT:
IMPORTANT:
The National Electric Code (NEC) requires 6 inches of extended wire from the wall box. If your wiring does not meet this requirement, you will not meet code. Do NOT cut wire shorter than 6 inches.
When installing this product in a commercial application or metal wall box, you might need to ground it to the wall box.
Control4 Wireless 6-Button Keypad Installation and User Guide 1
Connect the 6­button keypad wires
4
to the wall box wires using wire nuts. The wall box
wires can differ depending upon how it was wired by your electrician.
To wire the 6-button keypad for a Control4 single-switch environment with the power coming from a nearby power outlet or light switch, connect and cap with a wire nut the wires indicated in the table.
Wires from 6-Button Keypad Power Outlet or Light Switch
White (neutral) White (neutral)
Black (hot) Black (hot)
Green (ground) Green (ground)
Troubleshooting
If light does not turn on:
Ensure light bulb is not burned out.
Ensure light bulb is screwed in tightly.
Ensure circuit breaker is not turned OFF or tripped.
Check for proper wiring.
Multi-Unit Installations
Multi-unit installations allow you to install one stand-alone 6-button keypad next to another in the same wall box. Multi-unit keypads ship pre-connected. DO NOT remove side tabs from outer sides.They help to regulate the capacity.
With both sides intact (single unit), the capacity is 1000W maximum.
If you remove one side, the capacity is reduced to 800W maximum.
If you remove two sides, the capacity is reduced to 600W maximum.
Included Accessories
. Fit wires back into the wall box. Bend the
5
wires in a zigzag pattern so that they easily fold into the wall box. Push the 6-button keypad into place. Adjust the 6-button keypad so that it is perpendicular to the floor. Tighten the two screws that hold it in position in the wall box.
Align 6-button keypad to wall box and fasten with screws,
6
unless you are using a Decora screw-on-style wall plate. If
you are using a screw-on-style wall plate, before fastening with screws, you must first align the wall plate with the 6-button keypad and the wall box.
If you are using the Control4
7
snap-on- style wall plate, snap it over the 6-button keypad now.
Wall Plate
J-Box Bolts
Plate Bolts
A/V/C Keycap Kit
Optional Accessories
Audio Keycaps
Video Keycaps
System Keycaps
Turn ON power at circuit breaker or
8
replace fuse from fuse box.
Test the see if it is working properly.
9
To operate and configure this 6-button keypad as a stand­alone device, refer to the documentation that shipped with your Control4 controller. Refer to information on configuring or setting up lighting.