Control 4 C4-AMP104, C4-AMP108 Installation And Setup Manual

4- and 8-Zone Power Amplifier Installation and Setup Guide
Supported Models
• C4-AMP104 4-Zone Power Amplifier
• C4-AMP108 8-Zone Power Amplifier
Box Contents
The following items are included in the box:
• Control4® 4-Zone or 8-Zone Power Amplifier
• IEC power cable
• Phoenix-style audio connectors (8)
• Phoenix-style trigger connectors (2)
• Warranty card
• 3U vented rack mount
• Eight (8) 8-32 x 3/8" flat-head screws
Requirements and Specifications
Requirements
Ensure that your home network wiring is in place before starting your system setup.
WARNING! To reduce the risk of fire, do not
install this device in a cabinet that is smaller than 20" (50.8 cm) wide x 20" (50.8 cm) deep x 12" (30.5 cm) high. If you do, the device may overheat.
AVERTISSEMENT ! Pour réduire les risques
d’incendie, ne pas installer cet appareil dans une armoire qui est plus petit que 20" (50.8 cm) de large x 20" (50.8 cm) de profondeur x 12" (30.5 cm) de haut. Si vous le faites, l’appareil peut surchauer.
Specifications
C4-AMP104 4-Zone Power Amplifier
Zone line inputs 4 stereo, RCA style
Zone speaker outputs 4 stereo, Phoenix style
Zone line outputs 4 stereo, RCA style
Global line input 1 stereo, RCA style
Global line output 1 stereo, RCA style
Rated wattage/channel (two channels driven)
Rated wattage/channel (all channels driven)
Rated wattage (bridged) 200W @ 8 ohms
Frequency response 20 Hz ~ 40 kHz (+/- 3dB)
Signal-to-noise ratio >-86dB A-weighted
THD <0.3% at 1 kHz
Zone input gain Yes
Global input gain Yes
Voltage input trigger 5 ~ 30V AC or DC
Voltage output trigger 5 ~ 30V AC or DC
Rack-mount kit Included—3U vented
Power requirements 100-240VAC, 50-60 Hz
Shipping weight 11 lbs (4.99 kg)
C4-AMP108 8-Zone Power Amplifier
Zone line inputs 8 stereo, RCA style
Zone speaker outputs 8 stereo, Phoenix style
Zone line outputs 8 stereo, RCA style
Global line input 1 stereo, RCA style
Global line output 1 stereo, RCA style
Rated wattage/channel (two channels driven)
Rated wattage/channel (all channels driven)
Rated wattage (bridged) 200W @ 8 ohms
Frequency response 20 Hz ~ 40 kHz (+/- 3dB)
Signal-to-noise ratio >-86dB A-weighted
THD <0.3% at 1 kHz
Zone input gain Yes
Global input gain Yes
Voltage input trigger 5 ~ 30V AC or DC
Voltage output trigger 5 ~ 30V AC or DC
Rack-mount kit Included—3U vented
Power requirements 100-240VAC, 50-60 Hz
Shipping weight 11 lbs (4.99 kg)
55W @ 8 ohms 100W @ 4 ohms
45W @ 8 ohms 60W @ 4 ohms
55W @ 8 ohms 100W @ 4 ohms
30W @ 8 ohms 40W @ 4 ohms
1
Environmental
Operational temperature
Humidity 5% to 95% non-condensing
Storage -4°F ~ 158°F (-20°C ~ 70°C)
Dimensions without rack-mount kit (H×W×D)
Dimensions with rack­mount kit (H×W×D)3U20.79" × 5.39" × 9.69"
Power requirements 115/230 VAC, 50~60 Hz
32°F ~ 104°F (0°C ~ 40°C)
Miscellaneous
2U
17.32" × 3.43" × 9.69" (440 mm × 87 mm × 246 mm)
(528 mm × 137 mm × 246 mm)
WARNING! Do not expose the apparatus to
dripping or splashing. Do not place objects filled with liquids near the apparatus.
Outputs 200W per zone at eight (8) ohms in bridged mode. Amplifier cannot support 4-ohm loads in Bridge mode.
• Manually adjustable input gain for each zone.
• Manually adjustable input gain for global input.
• Each zone has independent line level inputs and outputs.
• Each zone has Phoenix-style amplified outputs for reliable connectivity.
• Auto-sense inputs when Trigger is o.
• Trigger enables discrete standby control of amplifier.
• Device chassis is two (2) standard rack spaces and rack mountable using three (3) standard rack spaces configuring to EIA 19” rack standards.
AVERTISSEMENT ! N’exposez pas l’appareil à
l’égoutture ou à l’éclaboussement. Ne placez pas les objets remplis de liquides près de l’appareil.
WARNING! To reduce the risk of fire or
electrical shock, do not expose this apparatus to rain or moisture.
AVERTISSEMENT ! Pour réduire le risque du
feu ou de choc électrique, n’exposez pas cet appareil à la pluie ou à l’humidité.
IMPORTANT! Using this product in a manner
other than outlined in this document voids your warranty. Further, Control4 is NOT liable for any damage incurred with the misuse of this product. See “Warranty.”
IMPORTANT ! Employer ce produit en quelque
sorte autre que décrit dans ce document vide votre garantie. De plus, Control4 n’est pas responsable d’aucun dommage encouru avec l’abus de ce produit. Voyez que « garantie. »
Installing a Rack-mount Bracket
1 Slide the rack-mount bracket onto the amplifier.
Align the holes on the bracket edge with the holes on the amplifier.
2 Mount the bracket using eight (8) 8-32 x 3/8”
flat-head screws (included).
Features and Benefits
• Receives up to four (4) (4-Zone Power Amplifier) or eight (8) (8-Zone Power Amplifier) stereo inputs, plus one global input.
• Outputs four (4) (4-Zone Power Amplifier) or eight (8) (8-Zone Power Amplifier) class D amplified stereo zones at 55W per channel at eight (8) ohms or at 100W per channel at four (4)ohms (two channels driven simultaneously).
2