Followinga typical statusSMS issuedon request:
Shortdescription
Detaileddevice application info
inputclosed
inputopen
inputopen
inputopen
inputopen
inputopen
inputopen
inputopen
remainingtime to outputoff
clipmode and status
Mainpower failure detected
outputinactive
output active, remaining time to disable could follow
output active and latched
pulse clip sequence in progress
inputopen, inactive
Building 1
Apt. 5 living room
In 1 :close
In 2 :open
In 3 :open
In 4 :open
In 5 :open
In 6 :open
In 7 :open
In 8 :open
Out1: on 00:01:22
Clip:pulse on
Blackout
off
on
!on
|
open
Out status:
In1 - 8status:
Serialc
Before opening the unit disconnect
power supply and all live circuits
thatmay be connected.
ommunicationport and
optional backup battery are located
insidethe unit.
The front cover must be removed to
accessthe inside ofthe unit:
1. Push with two fingers on
top and bottom sides of
front cover to release it.
2. Pull the front cover and
keep it in a safe place.
The newer NiMH batteries are less harmful to the environment, have a longer life,
and contain recyclable materials. Recycling options available in your local area
should be considered when disposing of this product. Do not dispose of in fire.
The SIM card receptacle is intended for 3V SIM cards [GSM 11.12 phase 2+].
The SIM card must be inserted in the cardholder to put the unit into operation.
Make sure that there is no voltage applied to GsmControl+.
Disconnect also the backup battery, if any.Following the figure below:
1. Unlock the top cover using
a small screwdriver.
2. Slide up the top lid.
3. Insert the SIM card in the
receptacle, contacts must be
on the bottom side.
To remove the SIM
card repeat operations
1 and 2, gently pull the
SIM card out.
Do not operate without top cover, once the
SIM card has been inserted replace the top
lidand then connectpower supply.
ADVANCED CONFIGURATION, LOCAL CONTROL, TRACING AND OTHER
FEATURESARE AVAILABLE THROUGHSERIAL COMMUNICATIONLINK
Specific literature and software for PC running Microsoft Windows are
availablefor free downloadat .
Remove the front cover following the instructions to access the RJ45 8 pin
modular jack serial interface [P].
Link cable is available from local resellers.
Communication: RS-232(DCE)
300... 115200bit/s
7/8 data bits, 1/2 stop bits, 1 parity bit, 10/11 bit char length
Software handshake, Hardware handshake
GsmSuite
www.gsm-control.biz
1013.00.02
®®
RJ45 PINOUT
1. GND
2. RTS
3. GND
4. CTS
5. GND
6. TxD
7. GND
8. RxD
DB9-5
DB9-7
DB9-8
DB9-3
DB9-2
1
131211
10
987654
3
2
14
õ
P
If the unit is provided with UPS
feature, a backup battery can be
installed to keep the device
workingeven during powerfailures.
Once the front cover has been
removed:
1. Clip the battery to available
connector. This connector
must be isolated when
operating without backup
battery.
2. Push the battery into
retainer lids located under
front cover.
3. Replace the front cover to
close the unit.
Use only NiMH rechargeable
batteries 8.4V or 9.6V type.
WHEN USING BATTERIESAND
ACCUMULATORSADHERE TO
RELEVANT REGULATIONS
ACCESS INSIDE
BACKUP BATTERY
FREE CLIP CONTROLCONFIGURATION
COM PORT
1
2
3
1
8
1
2
3
SIM CARD
Anyregistered user cancontrol theoutput by meansof SMS.
Followingdefault commands canbe changedto any customtext using .
Moredetails available on .
Set output 1 ON [3]
Reset output 1 OFF
Set output 1 ON and LATCH (set again at further power on) [4]
Pulse output 1 (1...59 seconds, default 3”)
Status SMS request
Ringback request once command has been processed
Commands will be recognized both uppercase, lowercase and mixed, nested
within other text wherever placed inside the incoming SMS.
Multiple commands into same SMS are allowed.
[3] Specifying a time interval after the set command, output will be released
once set time has elapsed. If a power failure occurs, the remainig time is
missing, thus the output will be released. Commad syntax:
days
hours
minutes
[4] Specifying date/time after the set and latch command, output will be
released at specified expiry date/time. Output status will be recovered after
blackout providing the real time clock sync has been performed successfully.
day
month
year hours minutes -
Example:
turn ON output for 8 hours and 30 minutes,
send back a status SMS
turn on and latch the output until April 25, 2006 12:30
turn ON output,
GsmSuite
“AdvancedManual”
00 - 99
00 - 23
00 - 59
01 -31
01 - 12
00 99
00 23
00 59
S1
R1
M1
P1
D
B
S1ddhhmm dd
hh
mm
M1ddmmyyhhmm dd
hh
hh
hh
mm
S1000830 D
M12504061230
s1 B
text alien trailer
alien trailer
SMS CONTROL STATUS SMS
Registered users can control outputs by means of simple (free) calls. Supervisors
can set different activationtimes andoutputs behaviour issuingan SMS:
On time
Time to answer in toggle mode
none, pulse, toggle, reverse,dtmf
Clip feature is disabled, nothing happens on incoming calls from registered users.
Selecting this mode, incoming voice (or fax) call from registered user will turn on
the output for the time set in .
Incoming voice (or fax) calls will toggle the output on to off or vice-versa.
A ringback will be issued only when an output is turned on.
If the user waits online, after the time specified in GsmAlarm+ will answer,
playing a low tone after output release or four high tones after output activation.
No ringback will be issued in such case.
+2,290,,,pulse,,,,answ,mode
pulse
answ
mode
01 - 60” default 3”
01 - 60” default 15”
NONE
PULSE (default)
TOGGLE
pulse
answ
2
1
1
Operatingwithout SIM PIN
Enterdefault SIM PIN
0000
Changedefault SIM PIN
GsmSuite
WARNING
The simplest way is to put your SIM card into a cellular phone and
program it so it won't ask for the PIN. The SIM card is 'open' and
someonecould steal theSIM card,use it andread theinformation inside.
GsmControl+comes with adefault PIN= (fourzeroes).
Putyour SIM cardinto acellular phone andprogram thePIN using the
givennumber.
Usingcom port and running onMicrosoft® Windows®
PCyou can modifythe defaultPIN on bothGsmControl+ andSIM card.
If you insert a SIM card that asks for a PIN number different from
that stored into GsmControl+, the device will not operate.
If you enter the PIN 3 times incorrectly, SIM card will lock up and you
must provide the PUK (PIN Unblocking Key).
Add Users (group 0)
Store first supervisor
Remote control is allowed to registered users only.
It's possible to add, modify or delete subscribers
from the SIM card phonebook using any GSM
mobile phone or SIM card reader/writer.
Following operating instructions provided by
phone manufacturer insert the SIM card into the
SIM card holder, turn on the phone and scroll the
option menu to enter the SIM card Phonebook edit
mode.
Enter the users name and telephone number using international format.
Insert the SIM card into the device SIM card holder and turn on the power supply,
the unit is ready to operate.
Although it is not mandatory to store a supervisor, you may add a supervisor who
then has additional special commands only available to him (advanced manual).
Tostore the first supervisor, once the unit is operative, issue the following SMS:
start character
system PIN (default = 0000)
supervisor’s name to be stored
optional email address
end character
Example:
The telephone number of SMS sender is automatically collected from the
incoming call presentation (thus the telephone number must be kept visible) and
will be assumed as the first supervisor’s telephone number.
First supervisor will be stored at position 401 and the unit will send back a
confirmation or error SMS.
Dots are allowed ONLY within the email address field.
It’s possible to use both and @ characters before the domain name.
SMS delivery failure is usually less than 1% but you must keep in mind
that a message could not arrive and you cannot complain with your
#xxxx.Name.email*
#
xxxx
Name
email
*
#0000.Harry Potter.harry.potter@hogwarts.com*
4 CHARACTERS
14 CHARACTERS MAX
40 CHARACTERS MAX
?
Toidentify your device more easily, you can store some specific information.
A supervisor can issue the following SMS:
Device own phone number [1]
Short description
Optional device own email address [2]
Detailed device application info
Example:
and will be shown within status SMS sent by this unit.
[1] Device phone number (always in international format) will be used to perform
real time clock autosync, missing this field the real time clock is unreliable and
SMS commands involving date field will be rejected.
[2] All email issued from Gprs type unit will be sent carbon copy also to its own
+3,300,tel,info,,,,,email,text
tel
info
email
text
+3,300,+4456789,Building 1,,,,,,Apt. 5 living room
info text
20 CHAR MAX
14 CHAR MAX
40 CHAR MAX
56 CHAR MAX
QUICK START
SIM PIN
DEVICE INFO
Special control SMS are reserved for supervisors only:
Disable / enable free calls control feature (CLIP).
An SMS reporting last # (1-9) answered / unanswered call list will be sent.
Full list specifying 0.
An Email reporting the complete phonebook will be issued to supervisor’s email
address, if any (GPRS only). Pbook ++ will return phonebook + settings.
Stop / Start
Lista# / Listu#
Pbook / Pbook++
AddRecipients (group 9)
Add / edit Supervisors (group 7)
Add / edit Users (group 0 / group 1)
Delete Phonebook entries
GPRS / Email settings
Alerts following local events can be issued to Recipients (upto 100).
Recipients stored in the internal memory of GsmAlarm+ can be modified using
GsmSuite with local link or by means of SMS issued by supervisors:
Phonebook index
Destination for phone calls [1]
Recipient’s name
Destination for SMS alerts [1]
Specific event Blackout
Input 1 closing
Input 2 closing
Input 3 closing
Input 4 closing
Input 5 closing
Input 6 closing
Input 7 closing
Input 8 closing
Power good
Input 1 opening
Input 2 opening
Input 3 opening
Input 4 opening
Input 5 opening
Input 6 opening
Input 7 opening
Input 8 opening
Remote tracing of all events
Destination for FAX alerts [1]
Destination for Extended SMS alerts [1]
Destination for email alerts [2]
Textof the message
Example:
Using GsmSuite is possible to configure advanced features, either linking the unit
with local com port or issuing SMS in remote mode. Refer to GsmSuite help file or
Advanced Manual for detailed information. Most important advanced features:
Up to 100 supervisors can be stored inside the unit.
Users can be stored into SIM card phonebook.
Conditional users (having more features) can be stored into device memory.
Remove any entry from phonebooks by means of GsmSuite or issuing an SMS.
Emails service configuration, available for GPRS devices.
+9,iii,Ring,Name,SMS,Event,Fax,XSMS,Email,Text
iii
Ring
Name
SMS
Event 00:
01:
02:
03:
04:
05:
06:
07:
08:
10:
11:
12:
13:
14:
15:
16:
17:
18:
30:
Fax
XSMS
Email
Text
+9,301,+44987654,Harry,,01,,,harry@harry.com,fire
+9,302,,Harry,,00,,+44987654,,power fail
+9,302,+44987654,Harry,+44987654,30
301 ÷ 400
20 CHAR MAX
14 CHAR MAX
20 CHAR MAX
20 CHAR MAX
20 CHAR MAX
40 CHAR MAX
56 CHAR MAX
Harry will receive both a phone call and an Email message when input 1 is
closing, the text of the message will be “fire”.
Harry Potter will receive an (extended) SMS including a complete status
report and the specific alert text “power fail“ detecting blakouts.
Harry Potter will receive both a phone call and an SMS at any local event,
text of the message is the event description including date and time.
SYSTEM COMMANDS