INPUTS
OUTPUT
Eight digital inputs coming from SPST contacts can be wired to terminals 7-14. Common return for contacts at terminal 6. Using electronic switches, terminal 6 is the positive leg. In order to avoid false triggering, contacts will be considered closed or open after 3 seconds from stable condition. Modifying the configuration by means of GsmSuite, either in local or remote mode it will be possible to change:
Debounce time from 1 to 99 seconds. Enable and disable input closing detection. Enable and disable input opening detection.
Contact voltage < 20 V Contact current<2mA 9 x 2.5 mm (AWG14) screw connector
Process or appliance can be controlled by means of 1 SPST relay contact available between terminals 3-4.
Rated current 4 A Rated voltage 250 Vac Max breaking capacity 2500 VA Minimum contact load 100 mA, 12 V Cadmium free contacts Insulation 250 V (IEC60664 / VDE0110b - cat. III / C) Surge voltage coil contacts: 4000V Dielectric strength coil-contacts 2500V
open contact circuit 1000V
4 x 2.5 mm (AWG14) screw connector
¡
¡
¡
DC
RMS
RMS
RMS
2
2
DECLARATION OF CONFORMITY
R&TTE Directive 1999/5/EC
Manufacturer: Contrive, Srl Via Enrico Fermi 18 24040 Suisio Italy
Brand: Contrive Equipment name:GsmAlarm+ / GprsAlarm+ Equipment type: GSM/GPRS modem
EMCC DR. RAŠEK, GmbH Moggast, Boelwiese 5 91320 Elbermannstadt Germany
Company identification:
Product identification:
We declare on our sole responsibility, that the product described above is in compliance with the essential requirements of the 1999/5/CE Directive:
EN 301 489-1 EN 301 489-7
EN 61326 EN 55024
EN 300 607
and all tests were carried out
Notified Body:
Health and safety requirements pursuant to clause 3.1a:
Protection requirements concerning EMC clause 3.1b:
Measures for the efficient use of the radio frequency spectrum clause 3.2:
EN 301 511
EN 60950-1
GSM900/1800 essential requirements for mobile stations
Safety of information technnology equipment
Electromagnetic compatibility ElectroMagnetic compatibility and Radio spectrum Matters Specific conditions for mobile and portable radio and ancillary equipments ElectroMagnetic compatibility measurement, control and laboratory use Information technology equipment - Immunity characteristics
Radio spectrum matters
NOTE: Class B equipment (domestic) emission level applied.
Class Aequipment (industrial) immunity level applied.
Suisio, Italy February 21, 2006
¡
¡
¡
CONTRIVE RESERVES THE RIGHT TO MODIFY THE CHARACTERISTICS STATED IN THIS INSTRUCTION MANUAL AT ANY TIME AND WITHOUT PRIOR NOTICE.
© COPYRIGHT 2002...2005 CONTRIVE SRL ITALY. ALL RIGHTS RESERVED.
GsmAlarm+A
GsmAlarm+X
The embedded antenna is located under the front panel. This omnidirectional antenna can work properly if the front side of the device is not shielded by metallic frames (i.e.: the GsmControl+A is installed inside a metal cabinet).
An externaldual-band antenna mustbe connected to theRF interface, implemented as a50 FME malecoaxial jack at the endof a short RG174 cablestub exiting from thetop side ofthe device.The antenna mustfulfil therequirements given below:
Werecommend a VSWRmax of 1.5:1although a VSWRmax of 2:1can be accepted withoutaffecting performance andcertification. The DC impedance is floating but there is no problem when using antennas that presenta short toground.
W
CONTRIVE S.R.L. ViaEnrico Fermi 18 I-24040SUISIO (Bergamo) Tel.+39 (0)35 4948236 Fax+39 (0)35 4933759
B1018.EN / 0211 www.gsm-control.biz
Dual band EGSM900 and GSM1800 for data, sms, fax and voice applications Full TypeApproved and compliant with ETSI GSM Phase 2+
Output power: Class4(2W@900MHz)
Class1(1W@1800 MHz )
Temperature: operating -20 to 55°C
storage and transport –30 to 85°C
Relative humidity: operating 5 to 95% non-condensing
storage & transport 5 to 95% condensation allowed outside Enclosure: EN-50022rail 4 modules, polycarbonate, UL94 -V0 Overall dimensions: mm 71 x 90 x 58(WxHxD) Weight: 200 g Degree of protection: IP 40 ( IEC 529) properly fittedEN-60529 /
Power supply: 12 V DC ±20% polarity independent
12 V AC ±20% < 30 mA @ 12 V DC in standby mode < 100 mA @ 12 V DC in standby mode, relays ON < 200 mA @ 12 V DC in communication mode < 1 A@ 12 V DC max peak current 2 x 2.5 mm (AWG14) screw connector
This unit can be supplied either by alternating or direct current, polarity independent. Power supply connection on terminal 1 and 2, top right side. The power supply unit must meet the demands placed on SELV [1] circuits in accordance with EN60950. The power supply must not be shared with other equipment: suggested power supply source is a simple 12VAC / 5VA transformer. The maximum permissible connection length between device and supply source is 3 m. Overvoltages are suppressed by internal varistor.
[1] Safety Extremely Low Voltage
2
This device should be installed only by qualified personnel. Carefully read the instructionmanual in itsentirety andkeep it safefor futurereference. It is essential to know the information and comply with the instructions given in the manualto ensure thefitting isinstalled, used andserviced correctlyand safely.
This RF unit is not designed for and intended to be used in portable applications (within20 cm or8 inchesof the bodyof theuser) and suchuses arestrictly prohibited.
This unit is not authorised for use as critical component in life-support devices or systemsunless a specificwritten agreementhas been given.
If incorrectly installed in a vehicle,the operation of GSM device could interfere with the correct functioningof vehicle electronics. Verificationof the protection of vehicle electronicsshould form apart ofthe installation. Regulationsmust be consideredto operatea vehicle’s lightor hornon public roads.
Nocomplex software orhardware systemis perfect. Bugsare always presentin asystem of anysize.
In order to prevent danger to life or property, it is the responsibility of the system designer to incorporate redundant protective mechanism appropriate to the risk involved.
All units are 100% functionallytested. Specifications are based on characterisation oftested sample unitsrather thantesting over temperatureand voltageeach unit.
Contrive disclaimsall liability for damageto the fitting orto other property orpersons deriving from installation, use and maintenance that have not been carried out in conformitywith this instructionmanual, whichmust always accompanythe fitting.
The GsmAlarm+is an industrialDIN rail GSMmodem for thesupervision and control of remoteinputs and outputsby means ofenhanced features availablethrough GSM network. Industrial standardinterface and an integratedSIM card reader mean itcan be used rapidly, easily and universally to quickly implement new applications in telemetry, telematicsand remote control. All interfacesare integratedin the housing. Theconnections are suitablefor usein domestic andindustrial environments.
DIMENSIONS[mm]
SAFETY INFORMATION
PRODUCT FEATURES
ANTENNA
PRODUCT DESCRIPTION
58
90
71
r
If the device has been stored in a cold environment, then condensation can occur. Before starting operations, the device must be absolutely dry. Thus, an acclimatization period of at least three hours must be observed.
In order to avoid possible damage, we recommend that you only use the specified accessories. These have been tested and shown to work well with this unit.
i
Do not install this unit near medical devices like pacemakers or hearing aids. This unit may interfere with the operation of these devices.
Switch off this unit when flying. Secure it so that it cannot be switched on inadvertently.
Do not install this unit near petrol stations, fuel depots, chemical plants or blasting operations when this unit can disturb the operation of technical equipment.
Interference can occur if this unit is used near televisions, radios or personal computers.
BUILTON PROVEN TECHNOLOGY
POWER SUPPLY
INPUTS / OUTPUT
Frequency TX
Frequency RX
Impedance
VSWR
TX max
RX max
Polarization
Typical gain
880 to 915 MHz
925 to 960 MHz
50 ohms
1.5:1
1.5:1
Linear
0 dBi in one direction at least
1710 to 1785 MHz
1805 to 1880 MHz
12345678
INSTALLATION
This unit can be installed on any standard EN-50022 rail by simple snap-in. A minimum protection degree IP40 must be guaranteed, raised to IP54 for open­air application.
A. Power Supply input
2 x 2,5mm (AWG14)
B. Input and output terminals
12 x 2,5mm (AWG14)
C. Input red led status indicators
D. Output green led status indicator
X. External antenna (type X only)
RG174 + FME male jack
S. GSM operation LED indicator
OFF No power supply
ON
Module switched ON Not registered on the network, missing SIM or invalid PIN
SLOW FLASH
Module switched ON Registered on the network
QUICK FLASH
Module switched ON Registered on the network Communication in progress
2
2
¡
¡
¡
¡
PERMANENTLY
200ms ON / 2s OFF
200ms ON / 600ms OFF
à
õ
õ
X
A
B
1
131211
10
987654
3
2
14
SD
C
Your GsmAlarm is the product of advanced engineering, design and craftmanship and should be treated with care. The suggestion below will help you to enjoy this productfor many years.
Bothfixed and mobileapplications areallowed, as definedbelow:
means that thedevice is physically secured at onelocation and is not able
tobe easily movedto anotherlocation.
means thatthe device is designedto be used in otherthan fixed locations and generallyin such away that a separationdistance of atleast 20 cm(8 inches) isnormally maintained betweenthe transmitter’s antennaand thebody of theuser ornearby persons.
Docontact an authorizedservice centerin the unlikelyevent ofa fault inthe unit.
¡
¡
¡
¡
¡
¡
¡
¡
¡
¡
Do not expose the unit to any extreme environment where the temperature or humidityare out ofoperating range.
Do notuse or storethe unit in dustyor dirty areas.Its moving parts (SIMholder for example)can be damaged.
Donot use chemicalcleaning agenton the unitor theSIM card. Donot attempt todisassemble theunit or removeany partor label.
Thereare no userserviceable partsinside. Donot expose theunit towater, rainor spilt beverages.It isnot waterproof. Donot abuse theunit bydropping, knocking orviolenty shakingit.
Roughhandling can damageit. Do not place the unit alongside computer discs, credit or travel cards or other
magneticmedia. The informationcontained onthese devices maybe affected. This unit is under your responsibility.Please treat it with care respecting all local
regulations. It isnot a toy.Therefore, keep it in a safeplace at all times and outof thereach of children.
Treat theSIM card with the samecare as your credit card:do not bend or scratch orexpose it tostatic electricity.
Try to remember your unlock and PIN codes. Become familiar with and use the securityfeatures to blockunautorised useand theft.
Fixed
Mobile
CARE AND MAINTENANCE
0678
1018.01.00 GsmAlarm+A
1018.02.00 GsmAlarm+A
1018.01.01 GsmAlarm+X
1018.02.01 GsmAlarm+X
1018.01.10 GprsAlarm+A
1018.02.10 GprsAlarm+A
1018.01.11 GprsAlarm+X
1018.02.11 GprsAlarm+X
EMBEDDED ANTENNA EMBEDDED ANTENNA + BACKUP BATTERY EXTERNAL ANTENNA EXTERNAL ANTENNA + BACKUP BATTERY EMBEDDED ANTENNA EMBEDDED ANTENNA + BACKUP BATTERY EXTERNAL ANTENNA EXTERNAL ANTENNA + BACKUP BATTERY
B
B
B
B
GsmAlarm+
GSM REMOTE MONITOR
GSM/GPRS REMOTE MONITOR
GprsAlarm+
USER GUIDE
12345678
THE INFORMATION CONTAINED IN THIS DOCUMENT ARE SUBJECT TO CHANGE WITHOUT NOTICE.PRODUCT NAMES, CORPORATE NAMES ORTITLES USED WITHIN THIS DOCUMENT MAYBE TRADEMARKS OR REGISTERED TRADEMARKS OF OTHER COMPANIES AND ARE MENTIONED ONLY IN AN EXPLANATORY MANNER TO THE READERS’BENEFIT,AND WITHOUTINTENTION TOINFRINGE.
WHILE EVERY EFFORT HAS BEEN MADETO MAKE SURE THE INFORMATION IN THIS DOCUMENT IS CORRECT, CONTRIVE CAN NOT BE LIABLE FOR ANY DAMAGES WHATSOEVERFOR LOSSRELATING TOTHIS DOCUMENT.
WARRANTIES
CONTRIVE GUARANTEES FOR TWO YEARS FROM THE DATEOF MANUFACTURE OF ITS PRODUCTTO REPLACE, OR, ATITS OPTION, TO REPAIRANY PRODUCT OR PART THEREOF WHICHIS FOUND DEFECTIVE IN MATERIAL ORWORKMANSHIP OR WHICH OTHERWISEFAILS TO CONFORMTO THEDESCRIPTION OF ITSSALES ORDER. CONTRIVE MAKES NO WARRANTY OF MERCHANTABILITY OR ANY OTHER WARRANTY EXPRESS OR IMPLIED. IN NO EVENT SHALL CONTRIVE BE LIABLE FOR CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY NATURE WHICH MAY ARISE IN CONNECTIONWITH SUCH PRODUCTS.
THE WARRANTY DOES NOT APPLY IN CASE OF IMPROPER USE
Followinga typical statusSMS issuedon request:
Shortdescription Detaileddevice application info
inputclosed inputopen inputopen inputopen inputopen inputopen inputopen inputopen remainingtime to outputoff clipmode and status Mainpower failure detected
outputinactive output active, remaining time to disable could follow output active and latched pulse clip sequence in progress
inputopen, inactive
Building 1 Apt. 5 living room
In 1 :close In 2 :open In 3 :open In 4 :open In 5 :open In 6 :open In 7 :open In 8 :open Out1: on 00:01:22 Clip:pulse on Blackout
off on !on |
open
Out status:
In1 - 8status:
Serialc
Before opening the unit disconnect power supply and all live circuits thatmay be connected.
ommunicationport and optional backup battery are located insidethe unit.
The front cover must be removed to accessthe inside ofthe unit:
1. Push with two fingers on top and bottom sides of front cover to release it.
2. Pull the front cover and keep it in a safe place.
The newer NiMH batteries are less harmful to the environment, have a longer life, and contain recyclable materials. Recycling options available in your local area should be considered when disposing of this product. Do not dispose of in fire.
The SIM card receptacle is intended for 3V SIM cards [GSM 11.12 phase 2+].
The SIM card must be inserted in the cardholder to put the unit into operation. Make sure that there is no voltage applied to GsmControl+.
Disconnect also the backup battery, if any.Following the figure below:
1. Unlock the top cover using a small screwdriver.
2. Slide up the top lid.
3. Insert the SIM card in the receptacle, contacts must be on the bottom side.
To remove the SIM card repeat operations 1 and 2, gently pull the SIM card out.
Do not operate without top cover, once the SIM card has been inserted replace the top lidand then connectpower supply.
ADVANCED CONFIGURATION, LOCAL CONTROL, TRACING AND OTHER FEATURESARE AVAILABLE THROUGHSERIAL COMMUNICATIONLINK
Specific literature and software for PC running Microsoft Windows are availablefor free downloadat . Remove the front cover following the instructions to access the RJ45 8 pin modular jack serial interface [P]. Link cable is available from local resellers.
Communication: RS-232(DCE)
300... 115200bit/s 7/8 data bits, 1/2 stop bits, 1 parity bit, 10/11 bit char length Software handshake, Hardware handshake
GsmSuite
www.gsm-control.biz
1013.00.02
®®
RJ45 PINOUT
1. GND
2. RTS
3. GND
4. CTS
5. GND
6. TxD
7. GND
8. RxD
DB9-5
DB9-7
DB9-8
DB9-3
DB9-2
1
131211
10
987654
3
2
14
õ
P
If the unit is provided with UPS feature, a backup battery can be installed to keep the device workingeven during powerfailures. Once the front cover has been removed:
1. Clip the battery to available connector. This connector must be isolated when operating without backup battery.
2. Push the battery into retainer lids located under front cover.
3. Replace the front cover to close the unit.
Use only NiMH rechargeable batteries 8.4V or 9.6V type.
WHEN USING BATTERIESAND ACCUMULATORSADHERE TO RELEVANT REGULATIONS
ACCESS INSIDE
BACKUP BATTERY
FREE CLIP CONTROLCONFIGURATION
COM PORT
1
2
3
1
8
1
2
3
SIM CARD
Anyregistered user cancontrol theoutput by meansof SMS. Followingdefault commands canbe changedto any customtext using . Moredetails available on .
Set output 1 ON [3] Reset output 1 OFF Set output 1 ON and LATCH (set again at further power on) [4] Pulse output 1 (1...59 seconds, default 3”) Status SMS request Ringback request once command has been processed
Commands will be recognized both uppercase, lowercase and mixed, nested within other text wherever placed inside the incoming SMS. Multiple commands into same SMS are allowed.
[3] Specifying a time interval after the set command, output will be released
once set time has elapsed. If a power failure occurs, the remainig time is missing, thus the output will be released. Commad syntax:
days hours minutes
[4] Specifying date/time after the set and latch command, output will be
released at specified expiry date/time. Output status will be recovered after blackout providing the real time clock sync has been performed successfully.
day month year ­hours ­minutes -
Example:
turn ON output for 8 hours and 30 minutes, send back a status SMS
turn on and latch the output until April 25, 2006 12:30
turn ON output,
GsmSuite
“AdvancedManual”
00 - 99 00 - 23 00 - 59
01 -31 01 - 12 00 99 00 23 00 59
S1 R1 M1 P1 D B
S1ddhhmm dd
hh mm
M1ddmmyyhhmm dd
hh hh hh mm
S1000830 D
M12504061230
s1 B
text alien trailer
alien trailer
SMS CONTROL STATUS SMS
Registered users can control outputs by means of simple (free) calls. Supervisors can set different activationtimes andoutputs behaviour issuingan SMS:
On time Time to answer in toggle mode none, pulse, toggle, reverse,dtmf
Clip feature is disabled, nothing happens on incoming calls from registered users.
Selecting this mode, incoming voice (or fax) call from registered user will turn on the output for the time set in .
Incoming voice (or fax) calls will toggle the output on to off or vice-versa. A ringback will be issued only when an output is turned on. If the user waits online, after the time specified in GsmAlarm+ will answer, playing a low tone after output release or four high tones after output activation. No ringback will be issued in such case.
+2,290,,,pulse,,,,answ,mode
pulse answ mode
01 - 60” default 3” 01 - 60” default 15”
NONE
PULSE (default)
TOGGLE
pulse
answ
2
1
1
Operatingwithout SIM PIN
Enterdefault SIM PIN
0000
Changedefault SIM PIN
GsmSuite
WARNING
The simplest way is to put your SIM card into a cellular phone and program it so it won't ask for the PIN. The SIM card is 'open' and someonecould steal theSIM card,use it andread theinformation inside.
GsmControl+comes with adefault PIN= (fourzeroes). Putyour SIM cardinto acellular phone andprogram thePIN using the givennumber.
Usingcom port and running onMicrosoft® Windows® PCyou can modifythe defaultPIN on bothGsmControl+ andSIM card.
If you insert a SIM card that asks for a PIN number different from that stored into GsmControl+, the device will not operate. If you enter the PIN 3 times incorrectly, SIM card will lock up and you must provide the PUK (PIN Unblocking Key).
Add Users (group 0)
Store first supervisor
Remote control is allowed to registered users only. It's possible to add, modify or delete subscribers from the SIM card phonebook using any GSM mobile phone or SIM card reader/writer. Following operating instructions provided by phone manufacturer insert the SIM card into the SIM card holder, turn on the phone and scroll the option menu to enter the SIM card Phonebook edit mode. Enter the users name and telephone number using international format. Insert the SIM card into the device SIM card holder and turn on the power supply, the unit is ready to operate.
Although it is not mandatory to store a supervisor, you may add a supervisor who then has additional special commands only available to him (advanced manual). Tostore the first supervisor, once the unit is operative, issue the following SMS:
start character system PIN (default = 0000) supervisor’s name to be stored optional email address
end character Example: The telephone number of SMS sender is automatically collected from the
incoming call presentation (thus the telephone number must be kept visible) and will be assumed as the first supervisor’s telephone number. First supervisor will be stored at position 401 and the unit will send back a confirmation or error SMS.
Dots are allowed ONLY within the email address field. It’s possible to use both and @ characters before the domain name.
SMS delivery failure is usually less than 1% but you must keep in mind that a message could not arrive and you cannot complain with your
#xxxx.Name.email*
# xxxx Name email *
#0000.Harry Potter.harry.potter@hogwarts.com*
4 CHARACTERS 14 CHARACTERS MAX 40 CHARACTERS MAX
?
Toidentify your device more easily, you can store some specific information. A supervisor can issue the following SMS:
Device own phone number [1] Short description Optional device own email address [2] Detailed device application info
Example:
and will be shown within status SMS sent by this unit.
[1] Device phone number (always in international format) will be used to perform
real time clock autosync, missing this field the real time clock is unreliable and SMS commands involving date field will be rejected.
[2] All email issued from Gprs type unit will be sent carbon copy also to its own
+3,300,tel,info,,,,,email,text
tel info email text
+3,300,+4456789,Building 1,,,,,,Apt. 5 living room
info text
20 CHAR MAX 14 CHAR MAX 40 CHAR MAX 56 CHAR MAX
QUICK START
SIM PIN
DEVICE INFO
Special control SMS are reserved for supervisors only:
Disable / enable free calls control feature (CLIP).
An SMS reporting last # (1-9) answered / unanswered call list will be sent. Full list specifying 0.
An Email reporting the complete phonebook will be issued to supervisor’s email address, if any (GPRS only). Pbook ++ will return phonebook + settings.
Stop / Start
Lista# / Listu#
Pbook / Pbook++
AddRecipients (group 9)
Add / edit Supervisors (group 7)
Add / edit Users (group 0 / group 1)
Delete Phonebook entries
GPRS / Email settings
Alerts following local events can be issued to Recipients (upto 100). Recipients stored in the internal memory of GsmAlarm+ can be modified using GsmSuite with local link or by means of SMS issued by supervisors:
Phonebook index Destination for phone calls [1] Recipient’s name Destination for SMS alerts [1] Specific event Blackout
Input 1 closing Input 2 closing Input 3 closing Input 4 closing Input 5 closing Input 6 closing Input 7 closing Input 8 closing Power good Input 1 opening Input 2 opening Input 3 opening Input 4 opening Input 5 opening Input 6 opening Input 7 opening Input 8 opening
Remote tracing of all events Destination for FAX alerts [1] Destination for Extended SMS alerts [1] Destination for email alerts [2] Textof the message
Example:
Using GsmSuite is possible to configure advanced features, either linking the unit with local com port or issuing SMS in remote mode. Refer to GsmSuite help file or Advanced Manual for detailed information. Most important advanced features:
Up to 100 supervisors can be stored inside the unit.
Users can be stored into SIM card phonebook. Conditional users (having more features) can be stored into device memory.
Remove any entry from phonebooks by means of GsmSuite or issuing an SMS.
Emails service configuration, available for GPRS devices.
+9,iii,Ring,Name,SMS,Event,Fax,XSMS,Email,Text
iii Ring Name SMS Event 00:
01: 02: 03: 04: 05: 06: 07: 08: 10: 11: 12: 13: 14: 15: 16: 17: 18:
30: Fax XSMS Email Text
+9,301,+44987654,Harry,,01,,,harry@harry.com,fire
+9,302,,Harry,,00,,+44987654,,power fail
+9,302,+44987654,Harry,+44987654,30
301 ÷ 400 20 CHAR MAX 14 CHAR MAX 20 CHAR MAX
20 CHAR MAX 20 CHAR MAX 40 CHAR MAX 56 CHAR MAX
Harry will receive both a phone call and an Email message when input 1 is closing, the text of the message will be “fire”.
Harry Potter will receive an (extended) SMS including a complete status report and the specific alert text “power fail“ detecting blakouts.
Harry Potter will receive both a phone call and an SMS at any local event, text of the message is the event description including date and time.
SYSTEM COMMANDS
Loading...