Contrinex RFC44HF User Manual

HF RFID SYSTEM
READ/WRITE MODULES (RWM)
RLH-C44PA-NSS
HOUSING READ/WRITE DISTANCE
C44 ~80 mm*
ü 40x40 mm plastic housing
ü Sensing face of PBTP ü Insensitive to dirt ü ISO15693 compatible
ü Networkable RWM using
ContriNET protocol
ü Cost optimized solution
* Please refer to table page 4
Carrier frequency 13.56 MHz Compatible standard ISO 15693 Data transfer rate (default in bold) 115 200 / 38 400 / 19 200 baud Maximum transmission speed 26.5 kbit/s Number of bits 7 / stop bits / parity 8 / 1 / None Read-write distance max.
ELECTRICAL DATA MECHANICAL DATA
Supply voltage range (Ub) 11...32 VDC Protection degree IP68 & IP69K No-load supply current (field off) x mA Ambient temperature range TA** -25...+80 °C Max. current consumption (no load) x mA Storage temperature range TS*** -25...+80 °C Short-circuit protection Voltage reversal protection
Max. output current 200 mA Connector type M12 4-pin
** Read/write operations possible *** Data retention and mechanical stability limit
~80 mm with RTP-0502-082 RWM configuration
ü ü
RS-485 configuration
LED yellow on Transponder detected LED yellow blinking RSSI level ≤ RSSI threshold ContriNET protocol
Sensing face material PBTP Housing material PBTP
Weight (incl. nuts) x g
ü
CONTRINEX AG Industrial Electronics
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 - Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
1
MOUNTING RECOMMENDATIONS
199
198
197
196
C7
C6
C5
C4
006
005
004
003
002
001
000
06
05
04
03
02
01
00
Block-Adressen
Adresses des blocs
Addresses of the blocks
Byte 0Byte 1
16 bit
HEXDEC
CLEARANCE
Read/write modules must not mutually influence each other. For this reason, a minimum distance of b between the devices must be observed.
A : metal free zone B : sensing face C : support
a : 80 mm b : x mm c : 90 mm d : 40 mm
WIRING DIAGRAM PIN ASSIGNMENT
Ub 11...32 VDC IA < 200 mA
A1 : RS-485 - B A2 : RS-485 - A
COMMUNICATION SETTINGS
RS-485 characteristics Value for RLH-C44PA-NSS
Data transfer rate (default in bold) 115 200 / 38 400 / 19 200 baud Number of bits 8 Number of stop bits 1 Parity No
3
4
2
1
M12
MEMORY STRUCTURE OF THE READ/WRITE MODULE
The Read/Write Module has a user memory of 3200 bits organized in 200 blocks of 16 bits. Each block is addressable separately by means of the commands Write RWM and Read RWM.
2
CONTRINEX AG Industrial Electronics
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 - Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
TYPICAL TIMES
Time name Description
Starting times
Polling time
Execution time of the commands
Time between the powering of the RWM and the end of the first scanning of the transponders present Time for actualization of the list of the transponders present. This time depends on the number of collisions. The execution time is defined as the time between the end of the sending of the command and the beginning of the answer
*Polling time for 16 transponders without collision
SLK-Strohmversorgung
Alimentation MLE
RWM power supply
Status
Durchsuchen nach laufenden Transponder
Balayage des transpondeurs présents
Scanning of the transponders present
Value
300 ms
70* ms
Command dependent
Zeit / Temps / Time
T
Start
T
Poll
Zeit / Temps / Time
TYPICAL EXECUTION TIMES BY COMMAND TYPE
Command type Description
Commands related to RWM Typical execution time 1.5 ms
Commands related to Transponder depending on number of blocks
Typical read duration: TR = T0 + N ·T Typical write duration: TW = T0 + N ·T
Duration for decoding the command - T
R0
W0
Read duration for one block (32 bits) - T Write duration for one block (32 bits) - T
0
R0
W0
Number of blocks concerned - N
Commands related to Transponder not related to a number of blocks
Typical execution time (e.g. Get System Info, Write AFI, Lock AFI, Write DSFID, Lock DSFID, and so on)
Signal
Befehl
Commande
Command
Antwort
Réponse
Answer
Value
12.0 ms
8.0 ms
12.0 ms
30 ms
CONTRINEX AG Industrial Electronics
Zeit / Temps / Time
Ausführungszeit
Temps d'exécution
Execution time
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 - Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
3
POSSIBLE COMBINATION AND TYPICAL DISTANCE - RLH-C44PA-NSS
x
S
Transponder type
Ø 9 RTP-0090-020 Ø 16 RTP-0160-020 Ø 20 RTH-D20QA-NC0 Ø 20 RTH-D20QA-ND0 Ø 26 RTP-0263-020 Ø 30 RTH-D30QA-NC0 Ø 30 RTH-D30QA-ND0 Ø 50 RTH-D50QA-NC0 Ø 50 RTH-D50QA-ND0 Ø 50 RTP-0502-022 Ø 50 RTP-0502-062 Ø 50 RTP-0502-082 ~80 ~40 ~80
[mm] S0 [mm] D0 [mm]
max
Read/Write Module
OUTPUT
Made by Contrinex
Model: RLS-C44PA-NxS
y
POWER
S
Working area
Transponder
D
0
0
S
max
AVAILABLE TYPES
Part number Part reference Sensing Face Mounting Connection
720 100 209 RLH-C44PA-NSS 40 x 40 mm Non-embeddable M12 4-pin
DISCLAIMERS
FCC information
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause interference
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note:This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
IC information
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence­exempt RSS(s). Operation is subject to the following two conditions:
(1) this device may not cause interference
(2) this device must accept any interference, including interference that may cause undesired operation of the device
Cet appareil contient des émetteurs / récepteurs exemptés de licence conformes aux RSS (RSS) d’Innovation, Sciences et Développement économ­ique Canada. Le fonctionnement est soumis aux deux conditions suivantes:(
(1) Cet appareil ne doit pas causer d’interférences
(2) Cet appareil doit accepter toutes les interférences, y compris celles susceptibles de provoquer un fonctionnement indésirable de l’appareil.
Contrinex information
Operators of the products we supply are responsible for compliance with measures for the protection of persons. The use of our equipment in applica­tions where the safety of persons might be at risk is only authorized if the operator observes and implements separate, appropriate and necessary measures for the protection of persons and machines. Terms of delivery and rights to change design reserved.
CONTRINEX AG Industrial Electronics
4
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 - Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
RLH-C44PA-NSS_190911_YAG
Loading...