The CX-1200 motion controller is used with various types of motor drives for precision control of
synchronized applications. The typical application consists of a syncronizing a continuous moving process
which can be of either two parts of a final product (e.g., bottles and bottle caps) or two parts of a machine
(e.g., gear keyway to conveyor flight).
This guide is intended to assist with the start up of elementary systems. More involved applications should be
implemented only after the system is working as herein described. Refer to the CX-1200 T echnical Refer enceManual for a comprehensive and detailed explanation of the CX-1200’s features and operations.
The CX-1200 start-up procedure consists of:
•Basic Wiring
•Operator Interface Primer
•System Setup Procedure
The following assumptions are made:
•Except for the changes required here, the CX-1200, including its PLC, will be programmed as factory
default.
•The default tuning for the CX-1200 should be stable for most applications and will not be discussed
here.
This information is useful (but not essential) to complete setup.
•Accel/Decel Rates: Adjust the Accel/Decel rates in the motor drive (amplifier), to their fastest rates
(shortest time), to allow the CX-1200 command signals to promptly generate a correct response from
the motor.
•Safety Stops/Inhibits/Enables: The CX-1200 has a Drive Enable open collector output, to be used
(via pilot relay if needed) to enable/disable the motor drive. This is important since there are situations
where the CX-1200 is trying to hold a “live zero”, or “active stopped”, H-Stop state. At other times the
drive enable is turned off (disabled). While the drive enable function could be part of some external
process control scheme, it is best to let the CX-1200 control the drives as required by the internal
control algorithms. Having said this, also consider SAFETY. The CX-1200 stop commands are solid
state items. Overall system safety would require interlocked, external, pushbuttons, contacts, etc. to
effect a disconnect type of safety stop. CX-1200’s “live zero” may appear to be a stopped condition, but
would NOT be safe to enter the machine for thread-up, jam clearing, etc.
Page 1
Page 2
—NOTES—
Page 3
BASIC WIRING
WARNING
The CX-1200 should only be installed by a qualified electrician.
Hazardous voltages may cause severe injury, death or equipment
damage.
The CX-1200 General Wiring Diagram illustrates the complete power and signal wiring for the CX-1200 control. Not
all of the connections will be required for your application. Refer to the CX-1200 Technical Reference Manual for
complete installation and wiring instructions.
The following instructions describe the basic wiring required for the master and follower modes of operation:
Power (J4 pins 1,2,3)
Position the power selector switch on the back of the CX-1200 to configure the power supply for 115 or 230 VAC. Wire
the power as shown in the diagram for 115 or 230 VAC.
WARNING
Applying 230 VAC power with the power selector switch in the
115 position will result in damage to the CX-1200 controller.
Run/Stop Logic (J6 pins 1,2,3,4,5)
In order to put the CX-1200 into “Run”, the F-Stop, R-Stop and H-Stop inputs must be shorted to common, usually
through a normally closed pushbutton. Short the Run input to common, usually through a normally open momentary
pushbutton. Thereafter, opening any of the Stop inputs will cause the CX-1200 to stop.
Jog Fwd/Rvs (J6 pins 6,7,8)
Jog Fwd/Rvs is a maintained input. When it is closed, it sends a Control Output signal to the drive at the selected Jog
Setpoint. As a maintained input, Jog Fwd/Rvs is only active when the operator device is closed.
Control Output (J3 pins 1,2)
The Control Output is a two wire connection between the CX-1200 and the Follower motor drive. Insure that the
isolated common (J3 pin 2) is not used elsewhere.
Drive Enable (J2 pins 1,9,10)
When this digital output is wired to the appropriate control input of the subject drive, it allows the CX-1200 to enable
and disable the drive as required. A low voltage pilot relay is usually required.
Frequency Inputs (J5 pins 1 thru 11)
The CX-1200 requires incremental or quadrature encoders for the lead/follower frequency inputs. Refer to the CX-1200Technical Reference Manual for detailed diagrams illustrating the connections for the frequency sensors.
Page 4
R
S
C
I
CX-1200 General Wiring Diagram
J5
J1
S485
erial
ommunications
nterface
+
EXTERNAL
DC
POWER
SUPPLY
(50V MAX)
TD/RD +
TD/RD -
Com
Zero Speed
Hi/Low Speed Alarm
Sync Alarm
Lead Sync Absent
Foll Sync Absent
Batch Done
Fwd/Rvs
Drive Enable
R
R
R
R
R
R
R
R
-
TD/RD +
1
TD/RD -
2
3
Com
RS485
Serial Comm
J2
+V_DO
1
DO_0
2
DO_1
3
DO_2
4
DO_3
5
DO_4
6
7
8
9
10
DO_5
DO_6
DO_7
Com
Digital Outputs
* +12VDC
Frequency Inputs
Reg In
J3
Signal Input
Drive Common
Motor Drive
CO_Sig
1
CO_Com
2
Output
Control
To Drive
Digital Inputs
FI_1A
FI_1A
FI_1B
FI_1B
Com
FI_2A
FI_2A
FI_2B
FI_2B
Com
RI_1
RI_2
J6
DI_0
DI_1
Com
DI_2
DI_3
DI_4
DI_5
Com
DI_6
DI_7
1
2
-
3
4
-
5
6
7
-
8
9
-
10
11
12
13
1
2
3
4
5
6
7
8
9
10
+12V PWR
A
-
A
B
-
B
Common
A
-
A
B
-
B
Common
+12V PWR
Lead
Quadrature
Sensor
Feedback
Quadrature
Sensor
Lead Sync
Foll Sync
F-Stop
R-Stop
H-Stop
Run
Jog Fwd
Jog Rvs
Keypad Lockout
Spare
FUSES
1 A
115 VAC
L1
NEUT
GND/PE
250 V
230 VAC
L1
L2
GND/PE
J4
L1
1
L2/NEUT
2
GND/PE
3
INPUT
AC POWER
CX-1200
*
Power for frequency input sensors may be supplied by J5, pin 1.
Total current should not exceed 150 mA .
J7
DI_8
DI_9
Com
DI_10
DI_11
DI_12
DI_13
Com
DI_14
DI_15
1
2
3
4
5
6
7
8
9
10
Block Select A
Batch Reset
Re-Learn
Open Loop
Position Reset
Sync Disable
Phase Advance
Phase Retard
Page 5
OPERATOR INTERFACE PRIMER
The remainder of the CX-1200 setup procedure involves setting control parameter values through the operator interface,
and then verifying system behavior using monitor parameters. The basic procedure for changing a control parameter is
first to locate the relevant parameter using the Menu, Page Up/Down and Parameter Up/Down keys, and then to modify
the parameter value using the Numeric or Scroll Up/Down keys.
The sequence for locating a control or monitor parameter using the menu driven interface is:
•Press the Menu key repeatedly until the Main Menu is displayed.
•Press the Parameter Up/Down keys to select the sub menu.
•Press the Enter key.
•Press the Parameter Up/Down keys to select the parameter category.
•Press the Enter key.
•Press the Page Up/Down keys, if necessary, to select the page.
•Press the Parameter Up/Down keys to select the parameter.
An alternative method for locating a parameter is through the code select procedure:
•Press the Code key to activate the code select line.
•Enter the numeric parameter code.
•Press the Enter key.
•The selected parameter is now displayed on the Status screen.
For each control parameter (CP) and monitor parameter (MP) required, the menu path will be shown as:
Go to MAIN MENU\SETUP\SYSTEM SETUP\PAGE 2.
Enter RUN Mode {CP-202} = 1 = Direct Mode.
The menu selections are separated by back slashes, “\”. The parameter code is
shown in the brackets,{}.
NOTE:The Help key accesses the Help screen and gives you a brief description of the parameter or subject that is
highlighted (active) on the screen. Press the Help key again to return to the previous screen.
Page 6
LCD
r
)
S
S
K
P
U
K
t
s
Screen
Display
Menu
Key
CX-1200 Operator Interface
ONTREX
C
CX - 1200
MAIN MENU
SETUP
SCALING
SETPOINTS & RAMPS
TUNING
ALARMS & LIMITS
BLOCKS
PLC
SYSTEM MONITOR
DEVICE TEST
Alm
MENU
CODE
Paramete
Up/Down
Keys
(Par Up)
(Par Dwn
Menu
Code
Key
tatus
creen
ey
age
p/Down
eys
Numeric
Keys
STATUS
7
4
1
-
89
5
23
0
HELP
Help
Screen
Key
6
CLEAR
.
ENTER
Incremen
Scroll Up/
Down Key
Clear
Key
Enter
Key
Page 7
SYSTEM SETUP PROCEDURE
This procedure is a series of steps designed to verify the motor/drive/encoder wiring and polarity setup some of the basic
parameters necessary for proper operation of the CX-1200.
Before you begin this procedure, the motor and drive must be wired and configured in accordance with the manufacturer’s
instructions. Refer to your drive manual to assist you in making the following drive adjustments:
•Set the maximum speed adjustment on the drive to deliver 10% more speed than the expected
maximum speed required for your application.
•Set the acceleration and deceleration times to their fastest settings.
•Set the IR compensation to its minimum setting.
•Set the Integral compensation to its minimum setting.
The CX-1200 must be configured and installed in accordance with the installation procedures indicated in the Installa-tion section of the CX-1200 Technical ReferenceManual and the CX-1200, including its PLC, will be programmed as
factory default.
NOTE:Sync Mode {CP-203} MUST have OFF selected. If the CX-1200 is not at factory default, then reference the
Operator Interface Primer, Kepad Operation,Code Select key and change Sync Mode {CP-203}.
Setup consists of the following:
•Freq In 2 & CO Setup
•Motor/Encoder Signal Polarity Setup
•Master Mode and Feedforward Scaling
•Lead Scaling
•Follower Mode Scaling
Motion will occur in the calibration procedure.
It is possible that sudden/violent motion could
result and cause damage or personal injury.
Make sure that the motor is secured in place.
Take all possible precautions to ensure your
DANGER
safety.
Page 8
DANGER
Hazardous voltages.
Can cause severe
injury, death or
damage
the equipment.
Make adjustments
with caution.
Page 9
Step 1 - Fr eq In 2 & CO Setup - Parameter Entry
Go to System Setup Freq In\Page 1.
Configure the CP’s on this screen as required.
State {MP-50}
Cnt Mode FI2 {CP-265}
PPR FI2 {CP-266}
CO Mode {CP-270}
CO Max V olts {CP-271}
Sync Mode {CP-203}
NOTE: The Help key accesses the Help screen and gives you a brief description of the parameter or subject
that is highlighted (active) on the screen. Press the Help key again to return to the previous screen.
NOTE: Sync Mode {CP-203} MUST have OFF selected. If the CX-1200 is not at factory default, then reference
the Operator Interface Primer, Kepad Operation,Code Select key and change Sync Mode {CP-203}.
Press the "Page Down" key to proceed to the next page.
Step 2 - Motor/Encoder Signal Polarity Setup - Parameter Entry
The CX-1200 will display System Setup Signal Polarity\Page 2.
Configure the CP’s on this screen as required.
State {MP-50}
RUN Mode {CP-202}
Direct SPx {CP-201}
CO Polarity {CP-272}
CO Offset {CP-273}
CO V olts {MP-37}
FI2 Hz {MP-03}
NOTE: The Help key accesses the Help screen and gives you a brief description of the parameter or subject
that is highlighted (active) on the screen. Press the Help key again to return to the previous screen.
Page 10
WARNING
Prepare the machine for motion.
Alert everyone present.
This test checks the Control Output polarity and the Encoder polarity, so a positive Control Output command causes
positive Encoder feedback.
Forward:
1. Enter RUN Mode {CP 202} = Direct.
2. Enter Direct SPx {CP-201} = +2.0 volts.
3. Place the control into "Run".
Verify forward motor direction:
4. If motor is running in the forward direction , skip to step 6.
5. Rewire the motor leads for forward direction.
Verify forward sensor polarity:
6. If FI2 Hz {MP-03} is a positive number, skip to step 8.
7. Rewire the feedback sensor polarity.
8. Place the control into "F-Stop".
Reverse:
Enter a direct mode setpoint for the reverse direction:
9. If CO Mode {CP-270} = Unipolar, skip to step 16.
10. Enter Direct SPx {CP-201} = -2.0 volts.
11. Place the control into "Run".
Verify reverse motor direction:
12. If motor is running in the reverse direction , skip to step 14.
13. Rewire the motor leads for reverse direction, verify the motor drive is bipolar or unipolar reverseable and
then recheck forward direction by returning to step 1.
Verify reverse sensor polarity:
14. If FI2 Hz {MP-03} is a negitive number, skip to step 16.
15. Rewire the feedback sensor polarity, and then verify the sensor polarity in the forward direction by
returning to step 1.
16. Place the control into "F-Stop".
17. Enter Direct SPx {CP-201} = 0 volts
Press the "Page Down" key to proceed to the next page.
NOTE: The Help key accesses the Help screen and gives you a brief description of the parameter or
subject that is highlighted (active) on the screen. Press the Help key again to return to the previous screen.
WARNING
Prepare the machine for motion.
Alert everyone present.
In this section, the master mode is scaled for engineering units. The feedforward is also scaled using the auto
feedforward feature. Master mode scaling should be completed even if your end application is not master mode.
The CX 1200 must convert the feedback frequency into engineering units (RPM, Feet/min, etc.). To do this, it
must “know” the ratio between encoder lines and these units. This ratio is entered in two parts, the first part
is FI2 Pulses and the second part is EU FI2 (Engineering Units for Frequency Input Number Two). For
example, if feedback is coming from a one foot circumference metering wheel driving a 1000 line encoder and
engineering units will be inches, then EU FI2 {CP-268} = 12.0 and FI2 Pulses {CP-267} = 1000.
1. Enter RUN Mode {CP-202} = Master.
2. Enter your FI2 Pulses {CP-267} .
3. Enter your EU FI2 {CP-268}.
Enter the desired master mode setpoint in engineering units:
4. Enter Master SPx {CP-201} = Desired speed.
Verify master mode scaling:
5. Place the CX-1200 control into “Run”.
6. If the Fb EU/Tm {MP-06} is not what you expect to see with the Master SP , then recalculate your scaling terms
and return to step 2.
Scale the feedforward:
7. Enter Kff Auto En {CP-364} = ON.
8. Wait several seconds.
9. Enter Kff Auto En {CP-364} = OFF.
10. Place the control into “F-Stop”.
Press the "Page Down" key to proceed to the next step.
Page 12
Step 4 - Lead Scaling - Parameter Entry
The CX-1200 will display System Setup Lead\Page 4.
NOTE: The Help key accesses the Help screen and gives you a brief description of the parameter or subject
that is highlighted (active) on the screen. Press the Help key again to return to the previous screen.
When it is in follower mode, the CX-1200 must convert the lead frequency into engineering units (RPM, Feet/
min, etc.). T o do this, it must “know” the ratio between encoder lines and these units. This ratio is enter ed in two
parts, the first part is FI1 Pulses and the second part is EU FI1 (Engineering Units for Frequency Input Number
One). For example, if the lead is coming from 60 tooth Quad Ring Kit on a motor armature driving a conveyor
with a 2 foot diameter roll through a 30:1 reduction and engineering units are feet, then FI1 Pulses {CP 262} =
1800 (60*30) and EU FI1 {CP 263} = 6.283 (2*3.14...).
1. Enter your FI1 Pulses {CP 262}.
2. Enter yourEU FI1 {CP 263}.
Verify the Lead Scaling:
3. Place the Lead control into “Run”.
4. If the Ld EU/Tm {MP-05} does not agree with the lead engineering units expected, then recalculate your scaling
terms and return to step 1.
5. Place the Lead control into “Stop”.
Press the "Page Down" key to proceed to the next page.
Page 13
Step 5 - Follower Mode Scaling
The CX-1200 will display System Setup Follower Mode\Page 5.
State {MP-50}
RUN Mode {CP-202}
Follower SPx {CP-201}
ScFbDisp EQU {CP-250}
Lg Number Units {CP-449}
NOTE: The Help key accesses the Help screen and gives you a brief description of the parameter or subject
that is highlighted (active) on the screen. Press the Help key again to return to the previous screen.
WARNING
Prepare the machine for motion.
Alert everyone present.
In this section, the follower mode is scaled for engineering units. Master mode and lead scaling should be
completed before proceeding with the follower mode scaling procedure.
1. Enter RUN Mode {CP 202} = Follower.
Set the Scaled Feedback display for the desired units:
2. Enter ScFbDisp EQU {CP 250} = Ratio.
3. Enter Lg Number Units {CP 449}.
In follower setpoint mode, the setpoint expresses the ratio between the follower and lead engineering units.
For example if the lead is in centimeters, the follower is in milliliters and the setpoint is 1.25, then the follower
will produce 1.25 ml per cm. Enter the follower setpoint as the ratio of follower to lead engineering units:
4. Enter your Follower SPx {CP-201}.
Verify the Follower Mode Scaling:
5. Place the CX-1200 control into “Run” and also place the lead control into "Run"..
6. If the relationship between the Lead and Follower sppeds are not what you expect, then recalculate your scaling
terms and return to step 2.
7. Place the CX-1200 control into “F-Stop” and the lead control into "Stop".
Procedure complete.
Page 14
—NOTES—
Page 15
Page 16
CONTREX, INC.
8900 Zachary Lane North
Maple Grove, MN 55369 USA
Phone:763.424.7800
Fax: 763.424.8734
www.contrexinc.com
info@contrexinc.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.