![](/html/ec/ecd2/ecd24ee68c47b42b195b3877f5318200a8a2778e90ecf6372597914d96c87a56/bg1.png)
80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current Waveform (ITHD = 6.064%, 50% Load)
1.04 0.82 12.95% 10% 97.99 11.43/0.03 3.35/1.33 4.99/1.33 4.98/0.34 86.40
88.17%
1.83 0.89 10.54% 20% 187.96 11.55/0.05 3.35/2.66 4.98/2.64 4.96/0.68 172.63
91.84%
4.14 0.98 6.06% 50% 464.63 11.9/0.13 3.32/6.66 4.95/6.61 4.91/1.7 430.10
92.57%
8.28 0.99 4.74% 100% 945.43 12.1/0.26 3.27/13.34 4.9/13.17 4.83/3.4 850.07
89.91%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency %
Input Watts
Output Watts
0
100
200
300
400
500
600
700
800
900
1000
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient power
supplies (greater than 80% efficiency in the active mode) in technology applications.
http://www.80plus.org/
-8
-6
-4
-2
0
2
4
6
8
-200
-150
-100
-50
0
50
100
150
200
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current