Continuum KL-C1050PL Energy label

80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
92.75%
AVERAGE EFFICIENCY :
91.85%
80 PLUS COMPLIANT:
YES
Value Units
Volts
15 Amps
50-60 Hz
1050 Watts
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current Waveform (ITHD = 6.05%, 50% Load)
-12V 3.3V 5V 5Vsb
1.07 0.97 14.54% 10% 118.94 11.5/0.03 3.33/1.37 5.08/1.37 5.07/0.26 106.43
89.48%
2.02 0.99 4.47% 20% 230.24 11.62/0.05 3.33/2.74 5.12/2.72 5.11/0.53 213.77
92.85%
5.08 1.00 6.05% 50% 582.20 12.01/0.13 3.33/6.86 5.24/6.8 5.2/1.31 540.02
92.75%
10.35 1.00 5.38% 100% 1187.90 12.49/0.26 3.18/13.74 5.08/13.58 4.99/2.63 1068.66
89.96%
Output
Watts
12.29/38.48
12.19/15.38
Efficiency
12.14/7.68
PF
12.22/76.86
Test Date
Input Frequency
5277
Type
ID Number
Model Number
4/16/18
2018
Serial Number
KOLINK
KL-C1050PL
N/A
Manufacturer
Rated Output Power
I
THD
Year
ATX12V
Rated Specifications
Input Voltage
Input
Watts
Load
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
Input Current
I
RMS
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
200
400
600
800
1000
1200
1400
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the 80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient power
supplies (greater than 80% efficiency in the active mode) in technology applications.
http://www.80plus.org/
-10.0
-5.0
0.0
5.0
10.0
-200
-100
0
100
200
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current