Continental Refrigerator FOBIK, S180227001, S180227002, S180227006, S180227007 User Manual

...
Continental Automotive GmbH B&S S2
User Manual
of the
Continental
Radio Frequency Transmitter
Type
S180227001 S180227002 S180227006 S180227007 S180227008 S180227010 S180227012
Continental Automotive GmbH
315 MHz variant
433,92 MHz variant
Center frequency
Frequency accuracy
RF modulation
RF frame data rate
Data coding
315 MHz variant
433,92 MHz variant
Center frequency
Frequency accuracy
RF modulation
Frequency Deviation
RF frame data rate
Data coding
B&S S2
Functional description of Fobik for RF Test
This document gives an overview of the different device operation modes and the RF transmissions performance of the key with specifical Software for Homologation. In this document the device is referenced as "key", even if the mechanical backup key might be separated from it.
1. RF parameters
For all RF transmission the following parameters apply: RKE Functioning
315 MHz 433.92 MHz ± 32 kHz ± 43 kHz ASK ASK
2.4 kBps 2.4 kBps Manchester Manchester
PASE Functioning
315 MHz 433.92 MHz ± 32 kHz ± 43 kHz FSK FSK +/- 14 kHz +/- 14 kHz
9.6 kBps 9.6 kBps Manchester Manchester
Continental Automotive GmbH B&S S2
2. Button functions
The validation of the accurate frequency deviation and the measurement of the transmission function of the key are implemented basing on RF test software. The graphic below shows the functionality of the buttons.
First Button
press
Button
unused
Second
Button
press
unused
comments
unused
Button
Button
Button
Button
Continuous
Burst emitting
CW; Central
frequency
DATA
Manchester
continuous
unused
Stop the
transmission
Stop the
transmission
Stop the
transmission
unused
Burst of 5 frames
ASK, Central Frequency
FSK, Low Frequency
DATA Manchester
Symbol 0
unused
Continental Automotive GmbH
Att
0 dB
RBW
VBW
SWT
30 kHz
100 kHz
2.5ms
1AP
Clrw
Ref -40.00 dBm
CF
Span
1.0 MHz
M1[1]
-54. 47 dBm
433.921000000 MHz
Att
0 dB
**RBW
VBW
SWT
3 MHz
10 MHz
10ms
1AP
Clrw
Ref -54.00 dBm
1.0 ms/
CF
433.9 21 MHz
M1[1]
-55. 51 dBm
10.000000000 ms
M1
RBW
SWT
10 kHz
30 kHz
5ms
1Pk
Max
Ref -20.00 dBm
CF
433.9 2 MHz
Span
500. 0 kHz
M1[1]
-27. 67 dBm
433.924000000 MHz
B&S S2
3. Button Actions
3.1 Carrier Wave Measurement
To perform radiated pattern or control the Level on GTEM you can pass the KeyFob with RF Test Software on CW emitting.
1. Push Unlock button to start the CW Transmission
2. Re-Push Unlock Button to stop the CW Transmission
-50 dBm
-60 dBm
-70 dBm
-80 dBm
-90 dBm
-100 dBm
-110 dBm
-120 dBm
-130 dBm
433. 921 MHz
M1
3.2 OBW Measurement
To perform Occuped BandWidth pattern you can pass the KeyFob with RF Test Software on Continuous ASK emitting (0 Manchester)
1. Push Trunk button to start the DATA 0 Transmission
2. Re-Push Trunk Button to stop the DATA 0 Transmission
-56 dBm
-58 dBm
-60 dBm
-62 dBm
-64 dBm
-66 dBm
-68 dBm
-70 dBm
-72 dBm
Att 0 dB
-30 dBm
-40 dBm
-50 dBm
-60 dBm
-70 dBm
-80 dBm
-90 dBm
-100 dBm
-110 dBm
VBW
M1
Date: 26.M AR.2014 11:47:51
Date: 26.MAR.2014 11:40:28
Continental Automotive GmbH
Att
10 dB**
*
RBW
VBW
SWT
30 kHz
30 kHz
1s
1AP
Clrw
Ref -10.00 dBm
100.0 ms/
CF
Vid
M1[1]
-28. 46 dBm
D1[1]
0.56 dB
542.000000000 ms
Att
0 dB
**RBW
VBW
SWT
3 MHz
10 MHz
200ms
1AP
Clrw
Ref -25.00 dBm
20.0 ms/
CF
315.00 659 MHz
Trg
Vid
M1[1]
-49.77 dBm
46.800000000 ms
D1[1]
-20.75 dB
78.800000000 ms
Att
10 dB**
*
RBW
VBW
SWT
30 kHz
30 kHz
1s
1AP
Clrw
Ref -10.00 dBm
100. 0 ms/
CF
Vid
M1[1]
-28. 46 dBm
D1[1]
0.56 dB
542.000000000 ms
B&S S2
To perform Occuped BandWidth pattern you can pass the KeyFob with RF Test Software on Continuous ASK burst emitting (Real Data Manchester)
1. Push Unlock button to start the DATA Transmission
2. Re-Push Unlock Button to stop the DATA Transmission
-30 dBm
-35 dBm
-40 dBm
-45 dBm
-50 dBm
-55 dBm
-60 dBm
-65 dBm
-70 dBm
M1
TRG -59.500 dBm
D1
Trg
-20 dBm
M1
-30 dBm
-40 dBm
-50 dBm
-60 dBm
TRG -60.000 dBm
-70 dBm
-80 dBm
-90 dBm
-100 dBm
433.9 24 MHz
-4. 000000000 ms
D1
3.3 DATA time Measurement
To perform Time Measurement use KeyFOB with Applicative SW
1. Quick Push buttons to transmit 1 Burst of 5 frames
Trg
-20 dBm
M1
-30 dBm
-40 dBm
-50 dBm
-60 dBm
TRG -60.000 dBm
-70 dBm
-80 dBm
-90 dBm
-100 dBm
433.9 24 MHz
-4. 000000000 ms
D1
Loading...