124 03 01 - 124 05 01 - 124 07 01
How to install, use and maintain your stove .
Norme NF D 35-301
Description of the appli ance
Installation instructions
Operating instructions
Spare parts
Warranty c ertificate
FR EN NL ES PT
PL
PL
PL PL PL
Description of the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Package . . . . . . . . . . . . . . . . . . 3
Specifications . . . . . . . . . . . . . . . 3
Regulations . . . . . . . . . . . . . . . . . 3
Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Warning to the user . . . . . . . . . . . . 4
Location of the unit . . . . . . . . . . . . 4
Chimney . . . . . . . . . . . . . . . . . . 4
Hearth . . . . . . . . . . . . . . . . . . . 5
Connections to flues . . . . . . . . . . . . 5
Mounting the tray . . . . . . . . . . . . . 6
Door closing pressure . . . . . . . . . . . 6
Pre-utilisation check . . . . . . . . . . . . 6
Soot Doors . . . . . . . . . . . . . . . . . 6
Commissioning . . . . . . . . . . . . . . . 6
Operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Lighting your stove . . . . . . . . . . . . 7
Air inlets . . . . . . . . . . . . . . . . . . 8
Fuel . . . . . . . . . . . . . . . . . . . . . 8
Maintenance . . . . . . . . . . . . . . . . 8
Fire-bricks . . . . . . . . . . . . . . . . . 8
Trouble Shooting . . . . . . . . . . . . . . 9
Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
CONTENTS Page Page
FRANCO BELGE congratulates you on your choice.
FRANCO BELGE, which has been granted the ISO 9001 certification, guarantees the
quality of its appliances and is committed to meet its customers needs.
FRANCO BELGE, which can boast a 75-year experience in the industry of heating devices,
uses state-of-the-art technologies
to design and manufacture its whole range of products.
This document contains instructions on how to install your appliance and make full use of
its functions, both for your comfort and safety.
Continental "La Parisienne" - ref. : 124 03 01 - 124 05 01 - 124 07 01
2 Technical manual "286"
Warning to the user
A wood stove should only be installed by competent personnel, in the strict
application of normal practices and all safety precautions.
An incorrectly installed wood stove can cause serious accidents (chimney fires,
burning of plastic insulation materials, in partition walls, etc.).
The manufacturers responsibility shall be limited to the supply of the equipment.
1.Description of the unit
1.1. Package
1 package : Stove complete.
1.2.
Specifications
Reference........................................ 1240301.....1240501..... 1240701
Nominalheatoutput ........................ kW ..........3 ......... 5 ......... 7
Roamheatingvolumecapacity .................. m
3
..........90........ 140 ........220
Weight ................................KGs ..........80 .........95.........105
Dimensions of the firebox
-Width ................................mm ......... 340........ 340 ........340
-Depth................................mm ......... 180........ 180 ........180
-Usableheight ...........................mm ......... 250........ 315 ........420
Logs dimensions
-Lenght ............................... cm..........25 .........30......... 40
-Diameter .............................. cm........ 10-16...... 10-16 ......10-16
Autonomy ............................... h..........8 ......... 8 ......... 8
Chimneydraftrequired....................... Pa ..........10 .........10.........10
Ashpancapacity ......................... Litre ......... 2,5.........2,5.........2,5
1.3.Regulations
Important : Before commencingthe installation of your
new Franco Belge appliance, it is recommended that the instructions are read and understood.
Health and Safety at WorkAct1974 : The installation
should comply with the Health and Safety at Work Act 1974 and particular reference to the following.
Handling : Adequate facilities should be provided for
handling the appliance.
Glass : On Franco Belge models incorporating glass
doors, extra care should be taken to avoid breakage.
Fire cement : C are sho uld be taken to avoid fire
cement contacting the skin. The material is causticand the event of contact being made, wash offimmediately with clean water.
Description of the unit
Figure 1 - Dimensions in mm
Continental "La Parisienne" - ref. : 124 03 01 - 124 05 01 - 124 07 01
Technical manual "286" 3
2.Installation instructions
The Parisienne comes bolted to a wooden pallet with a box over the top.
2.1.Warning to the user
An incorrectly installed heating appliance can cause serious accidents (chimney fires, burning of plastic insulation materials, in partition walls, etc.).
The installation must comply with Current Building Regulations. If in doubt, consult your Dealer or local Building Inspector.
It is the installer’s responsability to conform to local building standards and requirements with regard to installation.
The manufacturer’s responsibility shallbe limited tothe supply of the equipment.
2.2.Location of the unit
Ventilation :
For satisfactory operationwith a natural draught, check that sufficient air for combustion is available in the room.
Chimney position :
For new chimney installations, select a central position within the building, to provide a good heat distribution around the building.
Hearth :
The hearth must be suitable for use with solid fuel burning applia nces and must comply with Current Building Regulations. Ifin doubt, consult your Dealer or local Building Inspector.
Rear wall and ceiling :
The app liance must not be positioned close to combustible materials, wall & ceiling surfaces etc., Consult your Dealer or local Building Inspector if in doubt.
2.3. Chim ney
The chimney must comply with Current Building Regulations. If in doubt, consult your Dealer or local Building Inspector.
Existing flue :
The flue must be suitable for the installation of fuel burning appliances, otherwise it must necessary to install a tubing
The flue must be in good condition and must provide sufficient draught (refer to technical details p. 3 ).
The flue must be clean. It should be swept to remove soot and dislodge tar deposits.
The flue must be well insulated. If the flue inner wall surfaces are cold, a good thermal draw is impossible causing condensation problems (tar formation etc.) to occur.
Thefluemustbewatertight. The chimney must have a constant cross section. The flue must not be shared with other appliances. The chimney must be at least 4.5 m (15 ft high).
In case of aflat roof or when the roof gradientislower than 15°, the stack must be 1,2 m (4 feet) high at least.
The capping must not restrain the draught. If the chimney has any down draught tendency, due to
its position in relation to nearby obstacles, then an anti-down draught cowl must be installed on the chimney or the chimney height must be increased.
If the chimney draught is excessive or irregular, a draught stabilizer (barometric dampe r) mu st be installed to the connector pipe.
Flue non-existent :
The chimney must comply with Current Building Regulations. If in doubt, consult your Dealer or local Building Inspector.
The flue must not be supported by the stove. Consult a chimney specialist for advice on suitable flue
systems for solid fuel appliances.
It must be distant from any combustible material (walls, cross members)
It must permit an easy sweeping.
Installation instructions
300 mm
300 mm
300 mm
300 mm