Continental Hydraulics CEM-AC-E0-A, CEM-AC-E1-A Installation Manual

Continental Hydraulics Installation Manual
CEM-AC-E0-A CEM-AC-E1-A
Description:
This power amplifier mounts directly to a single solenoid proportional valve coil with a DIN style connector, and will drive up to 2.5A. It is suitable to control current to either a proportional flow or pressure valve coil. A wide range of analog signals are accepted. There are two product choices for input, one accepts voltage commands, the other accepts current commands. These inputs are ea sily scaled to match system requirements. Two independent ramps are available for acceleration and deceleration control. Min and Max output current are adjustable. Output characteristics can be independently customized. The module is disabled if the coil outputs are shorted or open. If command current is outside of the proper range, the module is also disabled. PWM and Dither are user adjustable. This module is easily adapted to a variety of system requirements. All variables are user adjusted with easy to use software on your Microsoft Windows laptop. Control variables are stored in non­volatile memory internal to the module. All variables can be read by the laptop, and reproduced exactly on other modules.
Technical Data:
Power Supply
Analog Input
Solenoid Output
Consumption
Impendance ohm 90k
Impendance
Resolution
Sample Time mS
PWM Frequency 60 to 2650 Dither Frequency
Dither Amplitute
Sample Time
vDC 12 to 30 (including ripple)
mA
<100mA + solenoid 3 (medium action)
AExternal Fuse
vDC 0 to +10 (voltage version)
Voltage
mA
Current
4 to 20 (current version)
390
ohm
%<0.1
1.0
AA1.2
2.5
Hz
60 to 400
Hz
0 to 30
%
0.17
mS
Software Selecta ble
Electrical Connectio n
Housing
Electro Magnetic Compatibility
Power and Signal
Communication
Housing
Combustability Class
Storage Temperature
Material
Protection Class
Humidity
Emission Immunity
Vibration Resistance EIC 60068-2-6
M12 5 pin male key style A
Ground via DIN coil pin
LIN bus
Attaches to DIN 43650 coil Polyamide PA
UL94
V1
IP 65 (with gasket)
-20 to +60
CWorking Temperature C
-20 to +70
% 95 (non condensing)
EN 61000-6-2 EN 61000-6-3
Page 1 of 8 CEM-AC-A CHI 1013472 April 2012
Continental Hydraulics Installation Manual
Functional Diagram:
Command input
(White)
Command Return
(Black)
0 to +10v
4 to 20 mA
+
-
or
Scaling
2 4
Input
CEM-AC-E0 CEM-AC-E1
Ramp
w
(voltage input) (current input)
Output Control
+12 to 24v
DC
1
(Brown)
3
0v (Gnd)
(Blue)
Sol A
DC
Output
uc
Communication
(Gray)
Wiring Example:
Dimensions:
5
Control Program
E0 - Voltage input
12-30vDC
Ground
0 to 10v
Ground
programming
E1 - Current input
12-30vDC
Ground
4-20 mA
return
programming
1
Power
3 2
Signal
4
(communications)
5
1
Power
3 2
Signal
4
(communications)
5
Ground via DIN
plug
Page 2 of 8 CEM-AC-A CHI 1013472 April 2012
1.3"
1.5"
M12 5pin male
3.1"
DIN 43650 Form A
5
43
12
Face view of
connector
on module
Continental Hydraulics Installation Manual
Steps to install and configure a new application:
1. Mount the module on the valve solenoid.
2. Connect the M12 cordset with power supply and command wires
3. Attach VEA-PB5 programming box tool
4. Connect programming tool to computer with VEA-USB programming cable
5. Adjust current range to match valve
6. Adjust PWM/Dither to optimize valve performance
7. Adjust analog input to scale command input
8. Adjust ramping (if desired)
9. Adjust internal monitor functions (if desired)
Module Mounting:
This module is to be mounted on a proportional valve solenoid with a DIN 43650 connector. It has an environmental protection rating of IP65. Additional external protection may be necessary on machinery subjected to extreme wash down conditions. Do not mount near other items that emit high power electrical interference, such as motor controllers and high power contactors.
Power Supply:
This amplifier module is designed to operate on DC power from a regulated power supply ranging from 12 to 30 volts. Match valve solenoid voltage rating to power supply, typically 12 or 24 volts.
A 3 amp medium action fuse is recommended in the “+” power supply line.
Wiring to Amplifier:
The CEM-AC products have an industry standard M12 5pin male electrical connector. Mating connectors or complete cordsets are available from many sources.
Voltage drop must be considered when selecting connecting cable. CHI offers the VEA-3P5C, a 5 meter long 22 gauge 5 conductor shielded cable cordset. The
voltage drop in this cable should be acceptable with 24v solenoid applications. Allowable voltage drop may limit the cable length in an application where the solenoid requires the full 2.5A.
Adjust MODE to STD or EXP:
The module wakes up in the default mode of STD. Several parameters may be adjusted while in STD mode.
EXP mode allows more complex parameter adjustments to the module. MODE parameter valid options are STD and EXP.
Page 3 of 8 CEM-AC-A CHI 1013472 April 2012
Loading...
+ 5 hidden pages