Warranty
General Instructions
General Information
Care of Glass & Plated Parts
5 - 12 VENTING
Venting Lengths
Air Terminal Locations
Typical Vent Installations
Special Vent Installations
Venting Application Flow Chart
Venting Specifications
13
-
18 INSTALLATION
Wall and Ceiling Protection
Using Flexible Vent Components
Fireplace Vent Connection
Using Rigid Vent Components
Restricting Vertical Vents
Gas Installation
Mobile Home Installation
Framing
Nailing Tab Installation
Mantle Installation
Ordering Replacement Parts
Replacement Parts
Vent Kits
Terminal Kits
Accessories
27-28 TROUBLE SHOOTING GUIDE
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
WARNING
••
• Do not burn wood or other materials in this fireplace.
••
• Adults and especially children should be alerted to the hazards of high surface temperatures and should
stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as
the fireplace.
• Due to high temperatures, the fireplace should be located out of traffic and away from furniture and draperies.
• Clothing or other flammable material should not be placed on or near the fireplace.
• Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace.
• It is imperative that the control compartments, burners and circulating blower and its passageway in the
fireplace and venting system are kept clean. The fireplace and its venting system should be inspected
before use and at least annually by a qualified service person. More frequent cleaning may be required due
to excessive lint from carpeting, bedding material, etc. The fireplace area must be kept clear and free from
combustible materials, gasoline and other flammable vapours and liquids.
• Under no circumstances should this fireplace be modified.
• This fireplace must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.
• Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to
inspect the fireplace and to replace any part of the control system and any gas control which has been under
water.
• Do not operate the fireplace with the glass door removed, cracked or broken. Replacement of the glass
should be done by a licensed or qualified service person. Use only with a glass door certified with the
fireplace.
• Do not strike or slam shut the fireplace glass door.
• This fireplace uses and requires a fast acting thermocouple. Replace only with a fast acting
thermocouple supplied by Wolf Steel Ltd.
NOTE: changes, other than editorial, are denoted by a vertical line in the margin.
W415-0385 / A / 10.02.03
CONTINENTAL gas fireplaces are manufactured under the strict Standard of the world recognized
ISO 9001 : 2000 Quality Assurance Certificate.
CONTINENTAL products are designed with superior components and materials, assembled by trained craftsmen
who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station.
Once assembled the complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure
that you, the customer, receives the quality product that you expect from WOLF STEEL Ltd..
CONTINENTAL GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY
3
The following materials and workmanship in your new The following materials and workmanship in your new
The following materials and workmanship in your new
The following materials and workmanship in your new The following materials and workmanship in your new
warranted against defects for as long as you own the fireplace. This covers: combustionwarranted against defects for as long as you own the fireplace. This covers: combustion
warranted against defects for as long as you own the fireplace. This covers: combustion
warranted against defects for as long as you own the fireplace. This covers: combustionwarranted against defects for as long as you own the fireplace. This covers: combustion
chamber, heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glasschamber, heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass
chamber, heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glasschamber, heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass
(thermal breakage only), gold plated parts against tarnishing, porcelainized enamelled compo-(thermal breakage only), gold plated parts against tarnishing, porcelainized enamelled compo-
(thermal breakage only), gold plated parts against tarnishing, porcelainized enamelled compo-
(thermal breakage only), gold plated parts against tarnishing, porcelainized enamelled compo-(thermal breakage only), gold plated parts against tarnishing, porcelainized enamelled components and aluminium extrusion trims.nents and aluminium extrusion trims.
nents and aluminium extrusion trims.
nents and aluminium extrusion trims.nents and aluminium extrusion trims.
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,
thermal switch, switches, wiring, remote controls, igniter, gasketing, and pilot assembly arethermal switch, switches, wiring, remote controls, igniter, gasketing, and pilot assembly are
thermal switch, switches, wiring, remote controls, igniter, gasketing, and pilot assembly are
thermal switch, switches, wiring, remote controls, igniter, gasketing, and pilot assembly arethermal switch, switches, wiring, remote controls, igniter, gasketing, and pilot assembly are
covered and covered and
covered and
covered and covered and
first year of the limited warranty.first year of the limited warranty.
first year of the limited warranty.
first year of the limited warranty.first year of the limited warranty.
Any labour related to warranty repair is not covered.Any labour related to warranty repair is not covered.
Any labour related to warranty repair is not covered.
Any labour related to warranty repair is not covered.Any labour related to warranty repair is not covered.
WOLF STEEL WOLF STEEL
WOLF STEEL
WOLF STEEL WOLF STEEL
LTD. LTD.
LTD.
LTD. LTD.
will provide replacement parts free of charge during thewill provide replacement parts free of charge during the
will provide replacement parts free of charge during the
will provide replacement parts free of charge during thewill provide replacement parts free of charge during the
CONTINENTALCONTINENTAL
CONTINENTAL
CONTINENTALCONTINENTAL
gas fireplace are gas fireplace are
gas fireplace are
gas fireplace are gas fireplace are
CONDITIONS AND LIMITATIONS
WOLF STEEL LTD. warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears
on the warranty registration card filed with WOLF STEEL Ltd. -- provided that the purchase was made through an authorized CONTINENTAL dealer and is subject to the following
conditions and limitations:
This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives.
The gas fireplace must be installed by a licenced, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with
the product and all local and national building and fire codes.
This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify
this warranty.
This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain
enamel parts, mechanical breakage of PHAZER™ logs and embers, nor any venting components used in the installation of the fireplace.
WOLF STEEL Ltd. warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During the first 10 years WOLF STEEL
Ltd. will replace or repair the defective parts at our option free of charge. From 10 years to life, WOLF STEEL LTD. will provide replacement burners at 50% of the current retail price.
In the first year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated
in accordance with the operation instructions and under normal conditions.
After the first year, with respect to this President's Limited Lifetime Warranty, WOLF STEEL LTD. may, at its discretion, fully discharge all obligations with respect to this warranty
by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).
WOLF STEEL Ltd. will not be responsible for installation, labour, or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not covered
by this warranty.
Notwithstanding any provisions contained in this President's Limited Lifetime Warranty, WOLF STEEL’S responsibility under this warranty is defined as above and it shall not in
any event extend to any incidental, consequential or indirect damages.
This warranty defines the obligations and liability of WOLF STEEL Ltd. with respect to the CONTINENTAL gas fireplace and any other warranties expressed or implied with respect
to this product, its components or accessories are excluded.
WOLF STEEL Ltd. neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. WOLF STEEL Ltd. will not
be responsible for: over-firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation,
excessive venting configurations, insufficient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes
dryers, etc.
Any damages to fireplace, combustion chamber, heat exchanger, brass trim or other component due to water, weather damage, long periods of dampness, condensation, damaging
chemicals or cleaners will not be the responsibility of WOLF STEEL Ltd.
The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty registration
card must be returned within fourteen days to register the warranty.
WOLF STEEL Ltd. reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.
THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes.
In absence of local codes, install the BCDV42 to the current
National Fuel Gas Code, ANSI Z223.1, or the current
CAN/CGA B149, Installation Codes.
Installation practices vary from region to region and it is
important to know the specifics that apply to your area,
for example: in Massachusetts State:
• The fireplace damper must be removed or welded in the open
position prior to installation of a fireplace insert or gas log.
• The appliance off valve must be a “T” handle gas cock.
• The flexible connector must not be longer than 36 inches.
• The appliance is not approved for installation in a bedroom or
bathroom unless the unit is a direct vent sealed combustion
product.
• WARNING: This product must be installed by a licensed plumber
or gas fitter when installed within the commonwealth of Mas
sachusetts.
Mobile home installation must conform with local codes or in the
absence of local codes, install to the current standard for gas
equipped mobile housing CAN/CSA ZA240 MH Series in Canada
or the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280, or the Fire Safety Criteria for Manufactured Home Installations, Sites and Communities St andard ANSI/
NFPA 501A in the United States.
The fireplace and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psig
(3.5 kPa). The fireplace must be isolated from the gas supply
piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig (3.5 kPa).
When the fireplace is installed directly on carpeting, vinyl tile
or other combustible material other than wood flooring, the
fireplace shall be installed on a metal or wood panel extending the full width and depth.
If the optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with
local codes. In the absence of local codes, use the current
CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the
ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United
States.
GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN
TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY!
Maximum input is 28,500 BTU/hr for natural gas and 24,000
BTU/hr for propane. When the fireplace is installed at elevations
above 4,500ft, and in the absence of specific recommendations
from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000ft.
Maximum output for natural gas is 19,500 BTU/hr at an efficiency of 68.5% with the fan on, and 16,000 BTU/hr for propane at an efficiency of 67% with the fan on. The maximum
A.F.U.E. (annual fuel utilization efficiency) rating is 64% for
natural gas and 61.5% for propane.
Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column for propane.
Maximum inlet gas pressure is 7 inches water column for
natural gas and 13 inches water column for propane. Manifold pressure under flow conditions is 3.5 inches water column for natural gas and 10 inches water column for propane.
This fireplace is approved for bathroom, bedroom and bedsitting room installations and is suitable for mobile home
installation.
No external electricity (110 volts or 24 volts) is re-No external electricity (110 volts or 24 volts) is re-
No external electricity (110 volts or 24 volts) is re-
No external electricity (110 volts or 24 volts) is re-No external electricity (110 volts or 24 volts) is required for the gas system operationquired for the gas system operation
quired for the gas system operation.
quired for the gas system operationquired for the gas system operation
Expansion / contraction noises during heating up
and cooling down cycles are normal and are to be
expected.
CARE OF GLASS, AND PLATED PARTS
Do not use abrasive cleaners to clean plated parts. Buff lightly
with a clean dry cloth. The BCDV42 is factory equipped with
tempered glass. The glass thickness is 3/16". Use only replacement glass available from your Continental dealer. DO
NOT SUBSTITUTE MA TERIALS. Clean the glass after the first
10 hours of operation with a recommended gas fireplace
glass cleaner. Thereafter clean as required. DO NOT CLEAN
GLASS WHEN HOT! If the glass is not kept clean permanent
discolouration and / or blemishes may result.
Use only accessories designed for and listed with
your specific fireplace.
Provide adequate ventilation air. Provide adequate accessibility clearance for servicing and operating the
fireplace. Never obstruct the front opening of the fireplace.
For safe and proper operation of the fireplace follow the
venting instruction exactly.
Deviation from the minimum vertical vent length can
create difficulty in burner start-up and/or carboning.
Provide a means for visually checking the vent connection to the fireplace after the fireplace is installed.
In order to avoid the possibility of exposed insulation or
vapour barrier coming in contact with the fireplace body,
it is recommended that the walls of the fireplace enclosure be 'finished', (i.e. drywall/sheetrock) as would any
other outside wall of the home. This will ensure that
clearance to combustibles is maintained within the cavity.
Vent lengths that pass through unheated spaces (attics, garages, crawl spaces) should be insulated with
the insulation wrapped in a protective sleeve to minimize condensation.
Objects placed in front of the fireplace must be kept a
minimum of 48" away from the front face of the unit.
W415-0385 / A / 10.02.03
VENTING
5
FIGURE 1
VENTING LENGTHS
Use only Wolf Steel or Simpson Dura-Vent Model DV-GS
venting components. Minimum and maximum vent lengths,
for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual
and must be adhered to. For Simpson Dura-Vent, follow
the installation procedure provided with the venting components.
When using Wolf Steel venting components, use only approved Wolf Steel rigid / flexible components with the following termination kits: WALL TERMINAL KIT GD422, or
1/12 TO 7/12 PITCH ROOF TERMINAL KIT GD410, 8/12 TO
12/12 ROOF TERMINAL KIT GD411, FLAT ROOF TERMI-
NAL KIT GD412 or PERISCOPE KIT GD401 (for wall penetration below grade). With flexible venting, in conjunction
with the various terminations, use either the 5 foot vent kit
GD420 or the 10 foot vent kit GD430.
It is recommended to attach the Wolf Steel 45º rigid adaptor directly to the unit when terminating horizontally off
the back of the unit. This must be done before attaching
the desired vent system. Once this transition has been
made, venting systems must not be combined.
These vent kits allow for either horizontal or vertical venting
of the fireplace. FIGURES 3 & 5. The maximum allowable
horizontal run is 20 feet. The maximum allowable vertical
vent length is 40 feet. The maximum number of 5" vent
connections is two horizontally or three vertically (excluding the fireplace and the air terminal connections) when
using aluminum flexible venting.
For optimum flame appearance and fireplace performance, keep the vent length and number of elbows to a
minimum.
The air terminal must remain unobstructed at all times.
Examine the air terminal at least once a year to verify
that it is unobstructed and undamaged.
Purge all gas lines with the glass door of the fireplace
removed. Assure that a continuous gas flow is at the
burner before re-installing the door.
Under extreme vent configurations, allow several minutes
(5-15) for the flame to stabilize after ignition.
Eight (8") inches is the minimum bend radius allowed
for the 8" diameter flexible liner.
For optimum performance it is recommended that all
horizontal runs have a 1 inch rise per foot when using
Continental flexible vent components.
A terminal shall not terminate directly above a sidewalk
or paved driveway which is located between two single family dwellings and serves both dwellings. Local
codes or regulations may require different clearances.
Do not allow the inside liner to bunch up on horizontal or
vertical runs and elbows. Keep it pulled tight. A 1¼" air
gap all around between the inner liner and outer liner is
required for safe operation. Use a firestop when penetrating interior walls, floor or ceiling.
Minimum clearance to combustible construction from fireplace and vent surfaces:
sides, back, bottom and top of the unit0 inch
recessed depth22 inches
top, sides and bottom of the vent pipe1 inch
vent heat shield1 inch
Horizontal runs may have a 0 inch rise per foot in all
cases using SIMPSON DURA-VENT or CONTINENTAL
RIGID OR FLEXIBLE venting components when venting as illustrated in Figures 3, and 4.
Only a clearance to combustibles of 1" all around the
vent pipe is required.
W415-0385 / A / 10.02.03
6
AIR TERMINAL INSTALLATIONS
FIGURE 2
INSTALLATIONS
CANADIANU. S.A.
A
12 INCHES
12 INCHES
Clearance above grade, veranda porch, deck or balcony.
B
C
D
E
12 INCHES
12 INCHES*
32 INCHES**
32 INCHES**
F
0 INCHES***
0 INCHES
9 INCHES
12 INCHES*
32 INCHES**
32 INCHES**
0 INCHES
0 INCHES***
G
2 INCHES***
H
I
J
K
L
M
N
O
*Recommended to prevent condensation on windows and thermal breakage
**Using a Napoleon soffit heat shield, W585-0096, or equivalent, the distance may be reduced to a minimum of
***The periscope GD-401 requires a minimum 18 inches clearance from an inside corner.
**** This is a recommended distance. For additional requirements check local codes.
†Three feet above if within 10 feet horizontally.
‡A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family
††Permitted only if the veranda, porch or deck is fully open on a minimum of two sides beneath the floor.
†*Recommenced to prevent recirculation of exhaust products. For additional requirements check local codes.
3 FEET
3 FEET
12 INCHES
6 FEET
7 FEET‡
32 INCHES††
16 INCHES
2 FEET†*
18". It is recommended to maximize the distance to vinyl clad soffits.
dwellings and serves both dwellings.
2 INCHES***
3 FEET****
3 FEET****
9 INCHES
3 FEET†
7 FEET****
32 INCHES****
16 INCHES
2 FEET†*
Clearance to windows or doors that open.
Clearance to permanently closed windows.
Vertical clearance to ventilated soffit located above the terminal within
a horizontal distance of 2 feet from the centerline of the terminal.
Clearance to unventilated soffit.
Clearance to an outside corner wall.
Clearance to an inside non-combustible corner wall or protruding
non-combustible obstructions (chimney, etc.).
Clearance to an inside combustible corner wall or protruding combustible obstructions ( vent chase, etc.).
Clearance to each side of the centerline extended above the meter
/ regulator assembly to a maximum vertical distance of 15ft.
Clearance to a service regulator vent outlet.
Clearance to a non-mechanical air supply inlet to the building or a
combustion air inlet to any other appliance.
Clearance to a mechanical air supply inlet.
Clearance above a paved sidewalk or paved driveway located on
public property unless fitted with a heat shield kit GD-301.
Clearance under a veranda, porch, deck or balcony.
Clearance above the roof.
Clearance from an adjacent wall including neighbouring buildings.
**
W415-0385 / A / 10.02.03
TYPICAL VENT INSTALLATIONS
NOTE:
When terminating vertically, the restrictor
plate W500-0205 must be installed. Refer to
Restricting Vertical Vents.
FIGURES 3 a-c
7
SPECIAL VENT INSTALLATIONS
PERISCOPE TERMINATION
Use the GD401 periscope kit to locate the air termination
above grade. The periscope must be installed so that when
final grading is completed, the bottom air slot is located a
minimum of 12 inches above grade. The maximum allowable vent length depends on the fireplace, as illustrated.
FIGURE 4
W415-0385 / A / 10.02.03
8
VENTING APPLICATION FLOW CHART
VERVER
TICALTICAL
VER
TICAL
VERVER
HORIZONTHORIZONT
HORIZONT
HORIZONTHORIZONT
TERMINTERMIN
TERMIN
TERMINTERMIN
vertical risevertical rise
vertical rise
vertical risevertical rise
is equal tois equal to
is equal to
is equal tois equal to
or greateror greater
or greater
or greateror greater
than thethan the
than the
than thethan the
horizontalhorizontal
horizontal
horizontalhorizontal
runrun
run
runrun
ALAL
AL
ALAL
AA
TIONTION
A
TION
AA
TIONTION
vertical risevertical rise
vertical rise
vertical risevertical rise
is less thanis less than
is less than
is less thanis less than
horizontalhorizontal
horizontal
horizontalhorizontal
runrun
run
runrun
TERMINTERMIN
TERMIN
TERMINTERMIN
vertical risevertical rise
vertical rise
vertical risevertical rise
is equal tois equal to
is equal to
is equal tois equal to
or greateror greater
or greater
or greateror greater
than thethan the
than the
than thethan the
horizontalhorizontal
horizontal
horizontalhorizontal
runrun
run
runrun
TICALTICAL
AA
TIONTION
A
TION
AA
TIONTION
verticalvertical
vertical
verticalvertical
rise is lessrise is less
rise is less
rise is lessrise is less
than hori-than hori-
than hori-
than hori-than horizontal runzontal run
zontal run
zontal runzontal run
horizontalhorizontal
horizontal
horizontalhorizontal
run + verti-run + verti-
run + verti-
run + verti-run + vertical rise tocal rise to
cal rise to
cal rise tocal rise to
maximummaximum
maximum
maximummaximum
of 40 feetof 40 feet
of 40 feet
of 40 feetof 40 feet
horizontalhorizontal
horizontal
horizontalhorizontal
run + verti-run + verti-
run + verti-
run + verti-run + vertical rise tocal rise to
cal rise to
cal rise tocal rise to
maximum ofmaximum of
maximum of
maximum ofmaximum of
24.75 feet24.75 feet
24.75 feet
24.75 feet24.75 feet
4.2 times4.2 times
4.2 times
4.2 times4.2 times
the verticalthe vertical
the vertical
the verticalthe vertical
rise equal torise equal to
rise equal to
rise equal torise equal to
or greateror greater
or greater
or greateror greater
than thethan the
than the
than thethan the
horizontalhorizontal
horizontal
horizontalhorizontal
runrun
run
runrun
horizontalhorizontal
horizontal
horizontalhorizontal
run + verti-run + verti-
run + verti-
run + verti-run + vertical rise tocal rise to
cal rise to
cal rise tocal rise to
maximummaximum
maximum
maximummaximum
of 40 feetof 40 feet
of 40 feet
of 40 feetof 40 feet
horizontalhorizontal
horizontal
horizontalhorizontal
run + verti-run + verti-
run + verti-
run + verti-run + vertical rise tocal rise to
cal rise to
cal rise tocal rise to
maximummaximum
maximum
maximummaximum
of 40 feetof 40 feet
of 40 feet
of 40 feetof 40 feet
3 times the3 times the
3 times the
3 times the3 times the
vertical risevertical rise
vertical rise
vertical risevertical rise
equal to orequal to or
equal to or
equal to orequal to or
greatergreater
greater
greatergreater
than thethan the
than the
than thethan the
horizontalhorizontal
horizontal
horizontalhorizontal
runrun
run
runrun
W415-0385 / A / 10.02.03
9
DEFINITIONS
for the following symbols used in the venting calculations and examples are:
> - greater than
> - equal to or greater than
< - less than
< - equal to or less than
H
- total of both horizontal vent lengths (HR) and off-
T
sets (HO) in feet
H
- combined horizontal vent lengths in feet
R
H
- offset factor: .03(total degrees of offset - 135°*) in
O
feet
V
- combined vertical vent lengths in feet
T
HORIZONTAL TERMINATION
when (H
Simple venting configuration (only one 45º and 90° elbow)