EISK5-100T/H
Skorpion Diagnostic Switch for Protocol Debugging
Installation Guide
The EISK5-100T/H is designed as an aid in diagnosing Ethernet communication
issues and debugging software. This device has all of the features of a normal
switch except that — like a repeating hub — it passes messages received by any port
to all other ports. This allows the activity of all ports to be monitored by a ―sniffer‖
attached to any port — an ability that would otherwise require the ―port mirror‖ function
of a more costly managed switch.
The five ports of the EISK5-100T/H offer features that traditional repeating hubs
do not. Each port supports Auto-MDIX — so either straight-through or crossover
cabling can be used. The collision domain is terminated at each port — so that a
network of EISK5-100T/H units has no cabling length limit — except that each
segment cannot exceed the 100 m specification for Ethernet. Store-and-forward
operation mitigates against lost messages. Each port automatically negotiates
its data rate to 10 Mbps or 100 Mbps — controlling data flow with the PAUSE
function in full-duplex links or with the backpressure method in half-duplex links.
Link integrity is monitored — verifying that a working device is on the far end of a
segment. In addition to the unit’s power LED, each port has two LEDs — one
showing link/activity/rate, and one showing duplex status.
The unit operates from low-voltage AC or DC power and is provided with a
writable label for easy identification of the remote device attached to each cable.

Specifications
Mechanical
Electrical
INPUT DC AC
Voltage: 10–36 V 24 V ±10%
Power: 3 W 6 VA
Frequency: N/A 47–63 Hz
Class 2 Circuits Only
Environmental
Operating Temperature: 0°C to +60°C
Storage Temperature: – 40°C to +85°C
Humidity, non-cond.: 10% to 95%
Protection: IP 30
Mounting TS-35 DIN-rail
Shipping Weight 1 lb (0.45 kg)
Regulatory Compliance
CE Mark; CFR 47 Part 15, Class A
UL508 Industrial Control Equipment
Functional
Compliance: ANSI/IEEE 802.3
Data Rates: 10 and 100 Mbps
Signalling: 10BASE-T and
100BASE-TX
Connectors: Shielded RJ-45
Segment length: 100 m (maximum)
LED Indicators
Power green
Activity/Link green or yellow
Duplex green
RJ-45 Pin Assignments
Pin Function
1 TD+
2 TD–
3 RD+
6 RD–
(All other pins are unused.)

Power Options
Power Considerations
Voltage within the specified range must deliver current that is commensurate with
power consumption. The recommended size for solid power conductors is 16–22
AWG; for stranded conductors, use 16–18 AWG. Ground is directly connected to
zero volts and the chassis is isolated from zero volts. Input connections are
reverse-polarity protected.
Network Connections
Auto-MDIX technology is employed so that either straight-through or crossover
cables can be used to connect to network interface adapters or to another hub.
LED Indicators
The ―PWR‖ LED glows solid green when the hub is properly powered. To aid in
troubleshooting, each port has two LEDs. The Port 1 LED labelled ―L‖ glows
solid if a link exists, flashes to show activity and shows data rate by colour: green
for 100 Mbps and yellow for 10 Mbps. The LED labelled ―D‖ glows solid green if
full-duplex is on or is unlit when that port is operating in half-duplex mode — but
in half-duplex operation it will flash if a collision occurs. The LEDs of Ports 2–5
are unlabeled but work the same.

Need more help installing this product?
For more information, visit www.ccontrols.com. If contacting our office, ask for
Technical Support.
Warranty
Contemporary Controls (CC) warrants this product to the original purchaser for
five years from the shipping date. If it fails to operate in compliance with its
specification during this period, CC will, at its option, repair or replace the product
at no charge. The customer is responsible for shipping the product; CC assumes
no responsibility for the product until received. This limited warranty covers
products only as delivered. If user modification damages the product, repair or
replacement are not covered. Damage from abuse, accident, disaster, misuse,
or incorrect installation are not covered. This warranty in no way warrants
suitability of the product for any specific application. More warranty information
can be found at www.ccontrols.com.
Warning: This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Returning Products for Repair
Return the product to the location where it was purchased by following the
instructions at the URL below:
www.ccontrols.com/rma.htm
Declaration of Conformity
Information about the regulatory compliance of this product can be found at the
URL below:
www.ccontrols.com/compliance.htm
September 2011 TD040420-0IC