LM2954 LINEAR INTEGRATED CIRCUIT
3
PARAMETER PART NUMBER TEST CONDITIONS MIN. TYP. MAX. UNIT
Load Regulation 100mA<=IL<=300 mA 0.2 0.5 %
Dropout Voltage IL=100mA
I
L=200mA (note 2)
50
38080450
150
600
mV
Ground Current IL=100mA
I
L=200mA
0.7580.12120.1414mA
Dropout Ground Current VIN=4.5V,I L=100mA 110 170 200 mA
Current Limit Vout=0 300 mA
Output Noise 10Hz to
100KHz
CL=1mF
C
L=200mF
C
L=3.3mF
(Bypass=0.01mF)
pins 7 to (
Contek 2954 )
430
160
100
mV
For 8-Pin Version Only
Reference Voltage 1.22 1.235 1.25 V
Reference Voltage (Note 7) 1.19 1.27 V
Feedback Pin Bias
Current
20 40 nA
Reference Voltage
Temperature Coefficient
50 ppm/ C
Feedback Bias Current
Temperature Coefficient
0.1 nA/ C
Error Comparator
Output Leakage Current VOH=30V 1 mA
Output Low Voltage VIN=4.5V
I
OL=400mA
250 mV
Upper Threshold Voltage (Note 3) 3.2 %VO
Lower Threshold Voltage (Note 3) 7.6 %VO
Hysteresis (Note 3) 15 mV
Shutdown Input
Input Logic Voltage
Low(Regulator ON)
High(Regulator OFF) 2.0
1.3
0.70
V
Shutdown Pin Input
Current
Vshutdown=2.4V 30 50 mA
Vshutdown=30V 450 600 mA
Regulator Output
Current Shutdown
Vshutdown>=2V,V IN<=30V,
V
out=0,
Feedback pin tied to 5V Tap.
310mA
Note 1: Additional conditions for 8-pin versions are feedback tied to 5V Tap an Output tied to Output Sense
(V
out=5V) and Vshutdown<=0.8V.
Note 2: Dropout Voltage is defined as the input to output differential at which the output voltage drops 100mV below
its nominal value measured at 1V differential.
Note 3: Comparator thresholds are expressed in terms of percentage value of voltage output.
CONTEK
Contek Microelectronics Co.,Ltd.
http://www.contek-ic.com E-mail:sales@contek-ic.com